In the design of structure, the forces acting on tai structure are key parameter fur noise and vibration control. However, in the complex structure, the forces at the injection point on the structure cannot be measured directly. So, it is necessary to find out Indirect force evaluation method. In this paper, forces have been measured with In-situ vibration responses and system information. And, three existing techniques of indirect force measurement, vita. direct inverse. principal component analysis and regularization have been compared. This paper shows that multi-vibration responses are essential for talc precise estimation of the forces. To check these conditions, rotary compressor is adopted as test sample, because it is very difficult to measure the injection forces from internal excitation to shell. It alas also been obtained that relatively higher force is transmitted through three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation with curvature shell and plate.