• 제목/요약/키워드: 나일론(NY)섬유

검색결과 12건 처리시간 0.022초

나일론 섬유의 길이변화에 따른 섬유보강 바닥마감용 콘크리트의 공학적 특성 (Engineering characteristics of the Fiber Reinforced Floor Finishing Concrete According to the changes of Nylon Fiber Length)

  • 전규남;백대현;정우태;박종섭;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.153-156
    • /
    • 2009
  • This study investigated the fundamental properties corresponding to various length changes on NY fiber reinforced concrete. For results of fresh concrete, the slump and air content were declined, but the unit volume weight and vebe time were increased. For the hardened concrete properties, the compressive strength showed increasing tendency according to the NY fiber length. The dry and autogenous shrinkage also decreased compared with Plain. Generally, the caes that 19 mm NY fiber was used was better than any other cases.

  • PDF

나일론 및 셀룰로스 섬유 혼입률 변화가 콘크리트의 공학적 특성에 미치는 영향 (Effect of the Nylon and Cellulose Fiber Contents on the Mechanical Properties of the Concrete)

  • 한천구;한민철;신현섭
    • 한국건축시공학회지
    • /
    • 제7권3호
    • /
    • pp.83-90
    • /
    • 2007
  • This study is to investigate the effects of nylon(NY) and cellulose(CEL) fiber contents on the mechanical properties of the concrete. The results were summarized as following. Test showed that increase of NY and CEL fiber contents decreased fluidity of fresh concrete, so the loss of the fluidity would be considered when they were over added. Air contents were slight increased, but they satisfied the target air content. Bleeding capacity of concrete containing fiber significantly was declined. In addition, concrete containing higher amounts of fiber retarded setting time remarkably. Plastic shrinkage crack was reduced with the use of fiber due to increasing fiber contents and changing fiber classes, and NY fibers to prevent the plastic shrinkage crack effectively. Compressive and tensile strength of almost specimens were increased when air contents of the fresh concrete were fixed according to fiber contents, and flexural strength was increased according to fiber contents. For the impact strength of specimens, the specimen containing $0.6kg/m^3$ of NY fibers, showed the most favorable impact strength, The fiber reinforced concrete using NY fibers exhibited superior mechanical performance, and it was considered that $0.6kg/m^3$ of was desirable as the most favorable adding amount.

섬유 종류가 도로포장용 콘크리트의 기초적 특성에 미치는 영향 (Effect of Fiber Types on Fundamental Properties of Pavement Concrete)

  • 한천구;박종섭;정우태;전규남
    • 콘크리트학회논문집
    • /
    • 제22권4호
    • /
    • pp.473-479
    • /
    • 2010
  • 이 연구에서는 도로포장용 콘크리트의 성능향상을 목적으로 폴리프로필렌(PP), 나일론(NY), 폴리비닐알코올(PVA) 및 셀룰로우스(CL)의 섬유 종류에 변화를 주어 도로포장용 섬유보강 콘크리트(FRC)의 공학적 특성을 분석하였다. 그 결과 굳지 않은 콘크리트의 특성으로 유동성은 OPC에 비해 섬유를 혼입할 경우 저하하는 경향을 나타내었으나, 혼합 즉시는 PP섬유, 60분 경시변화까지도 고려하면 NY섬유에서 가장 우수한 것으로 나타났다. 공기량은 OPC와 유사한 경향을 나타내며, 섬유 혼입으로 인한 공기량의 변화는 크지 않았다. 경화 콘크리트의 특성으로 압축강도 및 휨강도는 Plain에 비하여 모든 재령에서 섬유를 혼입할 경우 증가하는 경향을 나타내었는데, 섬유 종류별로는 NY, PVA, PP, CL순이었다. 단, 인장강도에서는 NY 및 PP일 경우만 증가하는 경향이었다. 포로시미터에 의한 세공분포는 NY섬유를 혼입할 경우 섬유의 영향으로 $1{\mu}m$ 전후의 세공량이 많이 분포하여 누적 세공량이 커지는 경향을 나타내었다. 따라서 유동성 및 강도 등을 종합적으로 고려할 때, 이 연구의 실험 조건에서는 NY섬유 혼입 시 최상의 결과가 도출되는 것으로 분석되었다.

복합섬유(PP,NY)를 혼입한 설계강도 80MPa 3성분계 고강도콘크리트의 폭렬특성 (Spalling Properties of 80MPa High Strength Concrete with Fiber)

  • 김성덕;이범식;배기선;김상연;박수희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.51-54
    • /
    • 2009
  • In this study, the fire resistance test was carried out with a parameter such as fiber(PP+NY) mixed ratio on high strength concrete with 80MPa, and the spalling resistance property was evaluated. Concrete material test was carried out with a parameter such as fiber(PP+NY) mixed ratio(0%, 0.05%, 0.1%, 0.2%) of high strength concrete with 80MPa. Although the flowability and the strength capacity were delicately decreased with a increase of fiber mixed ratio, they satisfied the target limits. As the spalling resistance property after the fire resistance test of 3 hours, the spalling was partly shown on the high strength concrete with fiber(PP+NY) mixed ratio of 0% but, wasn't shown on the high strength concrete with fiber(PP+NY) mixed ratio of 0.05% ~ 0.2%.

  • PDF

섬유의 종류 및 온도가열곡선 변화에 따른 콘크리트의 내화특성 (Fire Resistance of the Concrete Corresponding to the Various Fiber Contents and Heating Curves)

  • 한천구;배장춘
    • 한국건축시공학회지
    • /
    • 제8권5호
    • /
    • pp.101-107
    • /
    • 2008
  • This study investigated fundamental characters of the concrete according to various fiber types and contents and their properties of spatting resistance and residual compressive strength after fire test corresponding to ISO and RABT heating corves. The results were summarized as following. The Flowability was gradually declined as the increase of fiber contents, and it was the most favorable with nylon(NY) fibers. The decrease of air contents due to increasing fiber contents was in order by polypropylene(PP), polyvinyl alcohol(PVA) and NY fibers. The compressive strengths were over 40 MPa at 7 days and 50 MPa at 28 days. It was in order by PVA, PP and NY fibers. For the spatting properties, all specimens were prevented at ISO heating curve. In the other hand, the partial spatting at the surface occurred on the plain without fibers, but it was prevented over 0.10 % of PVA and 0.05 % of PP and NY fibers at the RABT heating curve.

나일론 섬유의 형상비 및 혼입률 변화에 따른 고강도 콘크리트의 폭렬특성 (Spalling Properties of High Strength Concrete Made with Various Aspect Ratios and Fiber Contents of Nylon Fiber)

  • 송용원;허영선;이성연;한창평;양성환;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.55-58
    • /
    • 2007
  • This study investigates the spatting properties of high strength concrete, $60\sim80MPa$ class, designed with diverse aspect ratios and fiber content of nylon(NY). Test showed that increase of fiber content and aspect ratio in concrete decreased the fluidity of fresh concrete, especially for 1580 and 3000 aspect ratio of fiber. As for the compressive and tensile strength, adding NY fiber did not significantly affect the values In the range of high strength. After completing the fire test, the specimens containing both 750 and 1000 aspect ratios of fiber protected the spatting occurrence even in 0.05vol.% of fiber content. This specimens indicated the residual compressive strength ratio at 37%, showing the most favorable value among other specimens. Therefore, it is demonstrated that to protect the spalling in high strength concrete considering the effective fluidity, strength and economic efficiency altogether, adding 0.05vol.% of NY fiber with 750 aspect ratio Is beneficial.

  • PDF

유기섬유 복합 혼입 고성능 콘크리트의 기초적 특성 (Basic Characteristics of High Performance Concrete Mixing Organic Fiber)

  • 박병관;유지영;이정아;김성일;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.87-91
    • /
    • 2008
  • The study examined fire resistance of concrete followed by change of mixed rate in PP and NY composite fiber and the results were as follows. In the event of fluidity in concrete not set, plane satisfied 600±100, its target slump flow, and fluidity was reduced as organic fiber's mixed rate was increased. Air amount satisfied 3.0±1.0, its target air amount, and didn't have distinct differences in reduction and increase according to organic fiber's kind and change of its mixed rate. However, it had a tendency that fluidity was reduced as the mixed rate was increased. In characteristics of hardening concrete, the 28th day compressive strength followed by organic fiber's kind and change of its mixed rate didn't have a lot of differences and satisfied high strength scope as about 70MPa. In spalling characteristics after fire resistance test, spalling was happened in non-mixture, plane combination, and P1N0. In other combinations, spalling resistance was happened. The relic compressive strength rate was 56%, the best condition, in P3N1(PP0.03%, NY0.01% compositeness) mixing PP fiber with NY fiber at once.

  • PDF

혼입 섬유종류 변화에 따른 고온가열 고강도 콘크리트의 역학적 특성 (Mechanical Properties of High Strength Concrete Subjected to Elevated Temperature Depending on Fiber Types and Contents)

  • 김상식;송용원;이보형;양성환;김성수;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.95-98
    • /
    • 2007
  • This study investigates the mechanical properties of the high strength concrete in the region of 80MPa corresponding to the temperature and fiber content change. For the properties of the fresh, slump flow is $600{\pm}100mm$, and air content is $3.0{\pm}1.0%$. They satisfy each targets, and there was no difference for the each fiber types. As the propertied of the hardened concrete, the compressive strength at 28 days is indicated over 80MPa, and they are similar to the change of the fiber types. The residual compressive strength in response to the temperature change of the NY, PP, and NY+PP fiber at $200^{\circ}C$ are increased by 115, 114, and 110% on the standard condition, and it is suddenly decreased at $400^{\circ}C$. They are decreased by 33, 19, and 16% on the standard condition at $800^{\circ}C$.

  • PDF

PVA 및 나일론 섬유 혼입률에 따른 PC 패널용 모르타르의 기초 물성에 관한 실험적 연구 (An Experimental Study for Basic Properties of Mortar Applied PC Panels by PVA and Nylon Fiber Ratio)

  • 이재현;송영찬;김용로;김욱종;이도범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.137-140
    • /
    • 2009
  • Nowadays, the high performance composite materials are famous for the new construction materials as the construction buildings are bigger and higher. Out of them of all, the fiber reinforced concrete and mortar have been studied to develop and strengthen the performances of concrete, such as tensile strength, durability and the resistibility of crack. Also, it is considered that precast concrete is important alternatives of dry process for saving time, upgrading the material's quality and the productivity. Thus, PC panel is being produced for the use of dry wall as well as exterior finishing materials and it requires lots of tests and studies to be conducted to meet the various functional conditions. According to this study, it is considered that PVA fiber might be more effective than nylon fiber for developing the exterior PC panels.

  • PDF

섬유 종류 및 피복두께 변화에 따른 고강도콘크리트 내화 특성 (Properties of Fire Resistance of High Strength Concrete as a Function of Type of Fiber and Cover)

  • 현태양;조윤구;김준형;임창근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.417-418
    • /
    • 2010
  • 본 연구는 3시간 내화실험으로 고강도콘크리트의 화재저항성을 파악하는데 그 목적이 있다. 섬유의 종류(폴리프로필렌, 나일론)와 콘크리트 피복두께(40mm, 50mm, 60mm)를 조절하여 실험을 하였다. 실험결과 충분한 양의 섬유를 혼입하였을 때 폭렬 저항성을 갖는 것으로 나타났다.

  • PDF