• Title/Summary/Keyword: assistive rehabilitation system

Search Result 132, Processing Time 0.025 seconds

Gaze Recognition Interface Development for Smart Wheelchair (지능형 휠체어를 위한 시선 인식 인터페이스 개발)

  • Park, S.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.103-110
    • /
    • 2011
  • In this paper, we propose a gaze recognition interface for smart wheelchair. The gaze recognition interface is a user interface which recognize the commands using the gaze recognition and avoid the detected obstacles by sensing the distance through range sensors on the way to driving. Smart wheelchair is composed of gaze recognition and tracking module, user interface module, obstacle detector, motor control module, and range sensor module. The interface in this paper uses a camera with built-in infra red filter and 2 LED light sources to see what direction the pupils turn to and can send command codes to control the system, thus it doesn't need any correction process per each person. The results of the experiment showed that the proposed interface can control the system exactly by recognizing user's gaze direction.

A Study for Co-channel Interference Mitigation in WBAN System (WBAN 환경에서 Co-channel 간섭 제거를 위한 연구)

  • Choi, W.S.;Kim, J.G.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.35-40
    • /
    • 2011
  • In this paper, we analyze that co-channel interference mitigation algorithms MMSE (Minimum Mean Square Error), OC (Optimal Combining), ML (Maximum Likelihood) using 2.4Ghz in WBAN (Wireless Body Area Network) system. Also analyze that scenario and channel model by IEEE 802.15.6. ML gives the best performance for all simulation. ML and OC have high complexity than MMSE complexity, because these algorithms should be known channel information of interference users. So these algorithms are difficult to apply to WBAN. Therefore we will study the interference mitigation algorithm that should be accomplished trade-off of between efficiency and complexity.

Development and Evaluation of the Auditory Feedback Gait Training System Induced Symmetrical Weight-Bearing in Hemiplegic Patients (편마비 환자의 대칭적 체중부하 유도를 위한 청각적 피드백 보행훈련 시스템 개발 및 평가)

  • Kwon, Y.C.;Lee, H.J.;Tae, K.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.2
    • /
    • pp.23-30
    • /
    • 2012
  • In this study, we developed a wireless rehabilitation auditory feedback gait training system for symmetrical weight-bearing in patient with CVA. The device consists of an instantaneous shoe equipped with two load-cell sensors. Auditory feedback can be applied according to the weight-bearing. For gait patterns analysis, cadence, walking velocity, stance/swing phase ratio and gait cycle were examined. The clinical test with six healthy volunteers and two hemiplegic patients was performed applying the auditory feedback system. Both normal subjects and hemiplegic patients were increased strength on weight-bearing in affected limb, walking velocity, and cadence after biofeedback device. Also, the stance time with weight-bearing was increased while the swing time was decreased in gait phase. It can be expected that by using the feedback system, the patient with lower limb disorder will be able to reach a better quality of weight-bearing during gait.

  • PDF

Quality Tests for the Knee-Orthosis Velcro and Locking System (무릎보조기 벨크로 및 잠금장치에 대한 품질시험 연구)

  • Jung, Se-Wook;Seo, Won-San;Cho, KiHun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.275-283
    • /
    • 2016
  • In this study, three knee-orthoses (dial lock type, medium size, right side) were used for a quality level test (static bending test and solidity test of the locking system) of the knee-orthosis locking system. In the static bending test, a smaller maximum load was observed in samples A and C compared to the reference standard value (KS P 8408 standard value: 1000 N, sample A: 865 N, sample C: 833 N). In addition, in the solidity test of the locking system, a smaller maximum load was observed in the all samples compared to the referenced standard value (KS P 8411 standard value: 200 N, sample A: 41 N, sample B: 97 N, sample C: 54 N). Korean industrial standards for knee-orthoses and systematic test methods are lacking. Therefore, a systematic management plan for knee-orthoses is required. The result of the current study showed that a systematic management plan for the knee-orthosis locking system is required. In particular, the development of a quantitative and objective test method is needed. The findings of the current study may be useful for monitoring the quality of the knee-orthosis locking system and may provide foundational information for the development of a quantitative and objective test method.

Analysis of Lower-Limbs Muscle Activity during Cycle Exercise in Spine Position (누운 자세에서의 자전거 운동 시 하지 근활성도 분석)

  • Shin, S.H.;Yu, M.;Cho, K.S.;Jeong, H.C.;Hong, J.P.;Hong, C.W.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.4
    • /
    • pp.331-337
    • /
    • 2015
  • This research was to develop the cycling system of lower limbs for rehabilitation during cycle exercise in supine position. Also we analyzed the muscular activity of lower-limbs at various exercise conditions according to exercise mode, load, velocity. 42 healthy subjects(ages 20-60 years) were participated. We measured the muscular activities of right lower limb muscle in rectus femoris, biceps femoris, tibialis anterior, medial gastrocnemius, soleus. Results, medial gastrocnemius shows high value on load 10 stage than load 1 and 5 stage. And all muscular activity except medial gastrocnemius was decreased as increase of velocity. We have found that there is a difference of lower limbs activity depending on exercise mode and method. This study could be applied to reference data to develop cycle system of lower limbs for rehabilitation.

  • PDF

Development of Medical Image Processing Algorithm for Clinical Decision Support System Applicable to Patients with Cardiopulmonary Function (심폐기능 재활환자용 임상의사결정지원시스템을 위한 의료영상 처리 기술 개발)

  • Park, H.J.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.1
    • /
    • pp.61-66
    • /
    • 2015
  • Chest X-ray images is the most common and widely used in clinical findings for a wide range of anatomical information about the prognosis of the disease in patients with cardiopulmonary rehabilitation. Many analysis algorithm was developed by a number of studies regarding the region segmentation and image analysis, there are specific differences due to the complexity and diversity of the image. In this paper, a diagnosis support system of the chest X-ray image based on image processing and analysis methods to detect the cardiopulmonary disease. The threshold value and morphological method was applied to segment the pulmonary region in a chest X-ray image. Anatomical measurements and texture analysis was performed on the segmented regions. The effectiveness of the proposed method is shown through experiments and comparison with diagnosis results by clinical experts to show that the proposed method can be used for decision support system.

  • PDF

Comparison of Electromyography Activity in Accordance with Contact Pad Type during the Use of a Standing Table for Pediatric Patients with Brain Lesions (뇌병변 소아환자의 기립보조기 사용 시 접촉 패드 유형에 따른 근활성도 비교)

  • Lee, J.H.;Oh, M.W.;Ha, J.G.;Seo, J.Y.;Hwang, H.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.3
    • /
    • pp.161-168
    • /
    • 2014
  • This study conducted a comparative analysis of the contraction pattern of trunk and lower limbs muscles of handicapped children with brain lesions during the use of foam pad and air pad for fixing a standing table to the body for pediatric patients with brain lesions using a standing table product applied with a pneumatic air fitting system. There was a difference in the measurement of muscle strength activity by muscle in accordance with pad type (foam pad vs. air pad). A large difference was found with big movements (movements of eating), while a small difference was discovered with small movements (writing and reading movements). This was found to furnish a little more comfort to users compared with the existing foam pad during the use of a standing table product applied with a pneumatic air fitting system.

  • PDF

Validation of Exercise Effect in Rehabilitation during Knee Extension of the Lower Limbs using Pneumatic Exercise System (공압운동기기의 하지 슬관절 운동 시 재활운동 효과의 유효성에 관한 연구)

  • Lee, H.J.;Kang, S.R.;Kim, K.;Jeong, G.Y.;Yu, M.;Kim, J.J.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • Our study is to verify validation of exercise effect that developing exercise and rehabilitation instrument using pneumatic actuators available rehabilitation and healthcare, while at the same time safer and more convenient for the user to select the desired exercise. Shares subject to the usual exercise is conducted in less than a week in the knee extension and flexion at the undergraduate level there is no more than 10 of the 20 patients were female. Subject performed knee exercise 3 set a day with 12times a set using fluid type exercise instrument and pneumatic exercise instrument that build in this study. Experiment has progressed in 4-weeks with 3-days a week. Our exercise load consist of two type. One is active exercise load with developed instrument in our study and the other one is passive exercise load with fluid instrument. Exercise program based on real-time muscle activation patterns and muscle activity before and after exercise by comparing the effects of exercise for rehabilitation has been verified. The results showed that muscular activity is higher in active exercise load than passive load, and improvement of muscle strength more increased too. Equipment more user-centered exercise more effectively exercise may enhance muscle strength was found. This study can adapt rehabilitation program and exercise for patient and weaker. Also our system can provide easily and convenient prescription of rehabilitation for expert related rehabilitation.

A Study on Requirements and Test Methods for the Safety of Electromyographs and Evoked Response Equipments (근전도계 및 유발성 응답기의 안전 요구사항 및 시험방법 연구)

  • Moon, I.H.;Nam, K.I.;Park, S.K.;Park, S.G.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.3 no.1
    • /
    • pp.41-47
    • /
    • 2009
  • This paper describes requirements and test methods for the safety of electromyographs and evoked response equipments to be used for medical examination of the central nerve system and motor-sensory functions in cortex. We first establish internationally harmonized requirements for the safety, and then propose a test procedure and test methods corresponding to the requirements based on the international standards. However requirements for the performance of each equipments are not specified in order to admit maker's specifications. Using a electromyography equipment we verified validity of the test methods proposed. Results of this study can be used as a standard for approval of Korea Food and Drug Administration (KFDA).

  • PDF

An Energy Efficient Mac Protocol for WBAN through Flexible Frame Structure (WBAN 환경에 따른 유동적 상태 전환 Mac Protocol)

  • Choi, J.S.;Kim, J.G.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.35-40
    • /
    • 2013
  • In WBAN environment, it is very important to achieve energy efficiency of master and nodes, At the same time, a master also plays an important role in collecting data from nodes and controlling the nodes. By maintaining a master properly, any kinds of situation can be handled. Therefore, low power MAC protocol between a master and a node is highly required appropriately. We propose an improved MAC protocol by simply changing the frame structure of WBAN system. The simulation results show that the proposed scheme attains a lot of saving of energy consumption of master and each node compared with IEEE 802.15.6 and conventional schemes.

  • PDF