• 제목/요약/키워드: Silicone gel

검색결과 55건 처리시간 0.025초

애크릴릭 및 실리콘 계열 연성 의치상 이장재의 결합력에 관한 연구 (A Study for Bond Strengths of Acrylic and Silicone Based Soft Lining Materials)

  • 남은주;임주환
    • 구강회복응용과학지
    • /
    • 제16권1호
    • /
    • pp.27-36
    • /
    • 2000
  • One of the methods to improve the softness and comfortness of denture base is the use of soft denture liners. In this study, specimens were made by 2 kinds of acrylic based soft lining materials and 2 kinds of silicone based soft lining materials, and bonded to acrylic resin(Lucitone $199^{(R)}$). Then they were tested the differences of tensile bond strengths according to the materials, thickness, surface treatment and failure mode. 1. Tensile bond strength according to soft lining materials was increased in order of Coe-$soft^{(R)}$, $Mollosil^{(R)}$, $Trusoft^{(R)}$, Ufi-Gel $C^{(R)}$. The differences between groups were statistically significant at level of 0.05. 2. Tensile bond strength according to thickness of soft lining materials was increased in order of 3mm, 2mm, 1mm. The differences between groups were not statistically significant. 3. Tensile bond strength of treated surface showed higher bond strength than nontreated surface. The difference between groups was not statistically significant. 4. The failure mode of Coe-$soft^{(R)}$, $Trusoft^{(R)}$, $Mollosil^{(R)}$ were mainly cohesive failure, and that of Ufi-Gel $C^{(R)}$ were mainly adhesive failure.

  • PDF

비대성 흉터를 최소화하는 생체적합성 재료설계와 미니돼지에 대한 치료 효과 (Biocompatible Material Design Minimizing Hypertrophic Injury and Treatment Effects using a Mini-pig)

  • 김용환;김종우;진성훈;김이수;강명창
    • 한국기계가공학회지
    • /
    • 제16권6호
    • /
    • pp.95-100
    • /
    • 2017
  • Recently, biomedical-grade texture material gauze has often been used to treat wounds. At this time, it is difficult to remove scratches and pushed gauze; if you remove it with force, the tissue may separate and bleeding may occur again. In this study, we studied a method to apply medical-grade silicone material. Similar to the research result that hypertrophic wounds reduce the thickness of scar marks. Through mini-pig experiments, we evaluated the effects on scar treatment. The test results showed that the silicone cover layer applied to the wound site had a sealing effect on the wound area, skin temperature, and histopathological examination. In conclusion, gel treatment utilizing a biocompatible substance had the effect of minimizing hypertrophic scars.

수분 활성 실리카 겔 분산계의 전기유변학적 특성 (Electrorheological Properties of Water Activated Silica Gel Suspensions)

  • 안병길;최웅수;권오관;문탁진
    • Tribology and Lubricants
    • /
    • 제13권3호
    • /
    • pp.115-123
    • /
    • 1997
  • The electrorheological (ER) behavior of suspensions in silicone oil of silica gel powder (average particle size 49 $\mu$m) absorbed water was investigated at room temperature with electric fields up to 2.4 KV/mm. In this paper, for development of succcessful ER fluids used for wide temperature range later, we would like to know a fundamental understanding of water on ER effect. As a first step, the ER fluids involving water activated silica gel were measured not only the electrical characteristics such as dielectric constant, current density and electrical conductivity but also the rheological properties on the strength of electric field, the quantity of dispersed phase and absorbed water. From the experimental results that water absorbed to the particles directly affects to the surface charge density of electric double layer model proposed by Schwarz and makes dielectric constant and current density of ER fluids increase. The current density and dynamic yield stress $($\tau$_y)$ of water activated silica gel suspensions was in exponential proportion to the strength of electric field, the quantity of dispersed phase and absorbed water. And the optimum water quantity and weight concentration of silica gel for electrorheological effect were 4-5 wt% and 15 wt%, respectively.

자가 콜라겐주입술을 이용한 성대구증환자의 치료

  • 최홍식;이준협;정유삼;임영창;김광문
    • 대한음성언어의학회:학술대회논문집
    • /
    • 대한음성언어의학회 1998년도 제10회 학술대회 심포지움
    • /
    • pp.195-195
    • /
    • 1998
  • 성문부폐쇄부전(glottic insufficiency)를 수술적으로 치료하기 위한 노력은 여러 형태(silicone, hydrogen gel, teflon, etc.)의 성대이물주입술, 갑상성형술등 다양하게 시도되어 왔다. 그러나, 이러한 노력에도 불구하고 성문부폐쇄부전은 여전히 해결하기 어려운 문제로 남아있다. 여기에 1995년 Ford 등은 성문부폐쇄부전에 이은 음성장애치료의 새로운 접근방법으로 자가 콜라겐주입술(autologous collagen injection)을 소개하였다. (중략)

  • PDF

코헤시브 실리콘 젤 유방삽입물을 이용한 유방확대술 후 발생한 유방삽입물의 흉강내로의 이탈 및 파열 증례보고 (Rupture and Intrapleural Migration of a Cohesive Silicone Gel Implant after Augmentation Mammoplasty: A Case Report)

  • 이준용;김한구;김우섭;박보영;배태희;최주원
    • Archives of Plastic Surgery
    • /
    • 제38권3호
    • /
    • pp.323-325
    • /
    • 2011
  • Purpose: Breast implant ruptures and displacement are problematic complications after augmentation mammoplasty. The authors report a patient whose cohesive silicone gel implant ruptured and migrated into the pleural cavity after augmentation mammoplasty. Methods: A 23-year-old female had received augmentation mammoplasty at a local clinic a week before visiting our hospital. When the patient's doctor performed a breast massage on the sixth postoperative day, the left breast became flattened. The doctor suspected a breast implant rupture and performed revision surgery. The implant, however, was not found in the submuscular pocket and no definite chest wall defect was found in the operative field. The doctor suspected implant migration into the pleural cavity, and after inserting a new breast implant, the doctor referred the patient to our hospital for further evaluation. The patient's vital signs were stable and she showed no specific symptoms except mild, intermittent pain in the left chest. A CT scan revealed the ruptured implant in the left pleural cavity and passive atelectasis. Results: The intrapleurally migrated ruptured implant was removed by video-assisted thoracic surgery (VATS). There were no adhesions but there was mild inflammation of the pleura. No definite laceration of the pleura was found. The patient was discharged on the first day after the operation without any complications. Conclusion: Surgeons should be aware that breast implants can rupture anytime and the injury to the chest wall, which may displace the breast implant into the pleural cavity, can happen during submuscular pocket dissection and implant insertion.

Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

  • Kim, Sung-Eun;Jung, Dong-Woo;Chung, Kyu-Jin;Lee, Jun Ho;Kim, Tae Gon;Kim, Yong-Ha;Lee, Soo Jung;Kang, Su Hwan;Choi, Jung Eun
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.529-534
    • /
    • 2014
  • Background In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. Methods From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. Results The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. Conclusions By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

탄성파를 적용한 다중 위상 MR Elastography로부터의 점탄성 정수의 측정 (Measurement of Viscoelastic Constants from Multiple Phase MR Elastography Fitting Elastic Wave)

  • 정남채
    • 융합신호처리학회논문지
    • /
    • 제13권3호
    • /
    • pp.119-129
    • /
    • 2012
  • 의료분야에서 조직의 경화는 진단 또는 질환의 진행상황의 파악에 이용되는 중요한 정보의 한 가지이며, 객관적인 진단을 위해서는 경화의 정량적 계측법이 중요하다. 경화의 지표인 점탄성 정수를 비침습적으로 계측하는 방법으로 MRE(Magnetic Resonance Elastography) 법이 제안되고 있다. MRE 법에서는 전파파(propagating wave)의 국소 파장과 국소 감쇠율로부터 점탄성 정수를 구하는데 MRE 화상은 S/N 비가 낮아지므로, 잡음의 영향을 감소시키기 위하여 다중 위상 MRE 화상을 이용한 방법이 검토되고 있다. 본 연구에서는 다중 위상 MRE 화상에 함수를 적용하여 점탄성 정수를 측정하는 방법을 제안한다. 제안 방법은 다중 위상 MRE 화상에 점탄성파를 적용시키지만, 점탄성 정수의 공간방향으로의 변화율이나 화상에 포함된 잡음에 따라 측정값의 공간분해능을 임의적으로 설정할 수 있다는 장점이 있다. 시뮬레이션 화상을 이용한 실험과 silicone-gel phantom을 이용한 실험에 의하여 제안된 방법의 유효성을 확인하였다.

Trends in Acupuncture Training Research: Focus on Practical Phantom Models

  • Jang, Jung Eun;Lee, Yeon Sun;Jang, Woo Seok;Sung, Won Suk;Kim, Eun-Jung;Lee, Seung Deok;Kim, Kyung Ho;Jung, Chan Yung
    • Journal of Acupuncture Research
    • /
    • 제39권2호
    • /
    • pp.77-88
    • /
    • 2022
  • The purpose of this review was to identify research trends in acupuncture training systems and models and to analyze acupuncture training using phantom models. Articles on acupuncture training were retrieved from domestic and foreign electronic databases (PubMed, CNKI, CiNii, NDSL, KISS, RISS and KMBase). The search included studies conducted from January 1, 2010 to October 1, 2021. Acupuncture training was analyzed by categorization into acupoint location training and needling training. Acupuncture training was most frequently studied in China, acupoint location training was the most studied in 2012, and needling training was the most studied in 2013 and 2020. Among them, a silicone model with a sensor was used for training in acupoint location, and silicone and agarose gel were frequently used for needling training. Classifications of the phantom models for needling training by topic included phantom development, phantom-based education and evaluation system, phantom-based quantitative measurement, comparison of kinematic characteristics of hand motion between experts and beginners, and phantom models for acupoint location and needling training. Further research on the development of acupuncture practice training systems to improve practical skills is needed.

BellaGel breast implant: 6-Year results of a prospective cohort study

  • Oh, Joon Seok;Jeong, Jae Hoon;Myung, Yujin;Oh, Jeongseok;Kang, Shin Hyeok;Park, Eonju;Kim, Ara;Bang, Sa Ik;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • 제47권3호
    • /
    • pp.235-241
    • /
    • 2020
  • Background This is the first clinical study conducted among Asian women using breast implants manufactured by an Asian company. Four-year data regarding the safety and efficacy of BellaGel breast implants have already been published, and we now report 6-year data. Methods This study was designed to take place over 10 years. It included 103 patients who underwent breast reconstruction or augmentation using BellaGel breast implants. The rates of implant rupture and capsular contracture were measured and analyzed to evaluate the effectiveness of the breast implant. Results At patients' 6-year postoperative visits, the implant rupture and capsular contracture rates were 1.15% and 2.30%, respectively. The implant rupture rate was 3.77% among reconstruction cases and 0% among augmentation cases. The capsular contracture rate was 5.66% among reconstruction cases and 0.83% among augmentation cases. Conclusions The 6-year data from this planned 10-year study suggest that the BellaGel cohesive silicone gel-filled breast implant is an effective and safe medical device that can be used in breast reconstruction and augmentation.

비정질 실리콘 산화물을 이용한 리튬망간실리콘산화물의 합성 및 전기화학적 특성 평가 (Synthesis and Electrochemical Performance of Li2MnSiO4 for Lithium Ion Battery Prepared by Amorphous Silica Precusor)

  • 진연호;이근재;강이승;정항철;홍현선
    • 한국분말재료학회지
    • /
    • 제19권3호
    • /
    • pp.210-214
    • /
    • 2012
  • Mass production-capable $Li_2MnSiO_4$ powder was synthesized for use as cathode material in state-of-the-art lithium-ion batteries. These batteries are main powder sources for high tech-end digital electronic equipments and electric vehicles in the near future and they must possess high specific capacity and durable charge-discharge characteristics. Amorphous silicone was quite superior to crystalline one as starting material to fabricate silicone oxide with high reactivity between precursors of sol-gel type reaction intermediates. The amorphous silicone starting material also has beneficial effect of efficiently controlling secondary phases, most notably $Li_xSiO_x$. Lastly, carbon was coated on $Li_2MnSiO_4$ powders by using sucrose to afford some improved electrical conductivity. The carbon-coated $Li_2MnSiO_4$ cathode material was further characterized using SEM, XRD, and galvanostatic charge/discharge test method for morphological and electrochemical examinations. Coin cell was subject to 1.5-4.8 V at C/20, where 74 mAh/g was observed during primary discharge cycle.