• Title/Summary/Keyword: Connection line

Search Result 616, Processing Time 0.142 seconds

Unequal Power Divider using Parallel Connection Transmission Line (병렬 연결된 전송선로를 이용한 비대칭 전력 분배기)

  • Kwon, Sang-Keun;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.2
    • /
    • pp.202-207
    • /
    • 2013
  • In this paper, a high dividing ratio unequal power divider using parallel connection transmission line is presented. Because a very low impedance transmission line can't implement a microstrip technology, this can fabricate a parallel connection transmission line with high impedance. When we design a high dividing ratio divider, we need the very low impedance line. The parallel connection transmission line could be implemented to obtain a low impedance line characteristic. To validity this approach, we are implemented a 10:1 unequal divider at center frequency 1 GHz. The performances of power divider agree with simulation results.

The Research into Connecting System for Aerial Bundled Cable in Distribution Line (ABC 배전 접속 시스템에 대한 연구)

  • 이용순;최경선;주종민;이철호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.495-498
    • /
    • 2001
  • The distribution line through which electricity is supplied from substation to customer generally varies by underground line and overhead line. In contrast that the underground line is shielded, the overhead lines do not have the shield layer. To overcome this weak point of the overhead lines, the aerial bundled cable(ABC) connection systems have been developed. The basic concept of the ABC connection system is the application of the underground cable system containing complete shield layer to the overhead cable system. The ABC system is the innovative technologies which enable the prevention of electric shocks, reduction of the maintenance charge and damage of the cable. This paper give a full detail of vertical connection system applied within a country.

  • PDF

An Unequal Divider based on Transmission Line with Periodic Capacitor Shunt Connection (캐패시터가 주기적으로 병렬 연결된 전송선로를 이용한 비대칭 분배기)

  • Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.781-786
    • /
    • 2012
  • In this paper, we propose the design and performance of an unequal divider using transmission line with periodic capacitor shunt connection. To design divider with a high dividing ratio, we limit a high impedance line value to fabricate microstrip line and also, design a low impedance line of below $10{\Omega}$ using periodic capacitor shunt connection. As a design example, a 10:1 ratio divider was designed and measured at center frequency 1 GHz to show the validity of the unequal divider using periodic capacitor shunt connection. Its performance is in good agreements with the simulated results.

Development of the New Hormonic Eliminating Device Using Zig-Zag Connection and Open-Delta Mode (Zig-Zag 결선 및 Open-Delta 방식을 이용한 새로운 고조파 저감장치의 개발)

  • Lee, Sung-Ho;Kim, Gi-Sung;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.169-174
    • /
    • 2005
  • The conventional harmonic filters to reduce zero harmonic current from neutral reactors and Zig-Zag connection, have several disadvantages of the decreased reduction rate of harmonics under a light load, because they have the load factor-dependent reduction rate of harmonics, and the risk of potential breaking in the neutral line by heated neutral reactor. Based Zig-Zag connection and Open-Delta mode, this new harmonic eliminating device (HANOS) adopts the combination of Zig-Zag connection and Open-Delta mode-the latter is additionally applied to the transformer's core block for connection to the neutral line. The results of this study demonstrated that the new device could eliminate safely zero harmonic current running in the neutral line without heating.

A Approaches to the Problem in connection with the Circle in Point of View of the Angle and Arc (원과 관련된 문제에서 각과 호의 관점으로의 접근)

  • Kang, Jeong Gi
    • The Mathematical Education
    • /
    • v.51 no.4
    • /
    • pp.471-484
    • /
    • 2012
  • It is not easy to find the auxiliary line to solve the problem in connection with the circle, where it is the problem finding the central angle or angle at the circumference in a circle. The purpose of the study is to give an aid for this difficulties. The angle at the circumference is closely related to the arc. And so we looked into the problem in connection with the angle at the circumference in point of view of the arc. We have got the following the results. It is not necessary to draw the auxiliary line when solving the problem in connection with the angle at the circumference in point of view of the arc. And we can find the reason to draw the specific auxiliary in point of view of the arc. We hope that the results of research are given aids to a lot of students.

Power Flow Control of Modular Multilevel Converter based on Double-Star Bridge Cells Applying to Grid Connection

  • Hamasaki, Shin-Ichi;Okamura, Kazuki;Tsuji, Mineo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.2
    • /
    • pp.246-253
    • /
    • 2013
  • The Modular Multilevel Converter (MMC) with full bridge cells is available for utility interactive inverter in high voltage line. When it is interconnected with power line, it is possible to control the active power flow in order to supply or charge the power in the line. This research applied the MMC to grid connection system of distributed generator and a power flow control for the MMC is investigated. Theory of power flow between the MMC and the power line is described and control method of power flow and capacitor voltages on arm cells for the MMC are proposed. And effectiveness of the proposed control method is presented by simulation.

Optimization of DC Operating Voltage for GDT-Adopted SPD (가스방전관(GDT)을 적용한 서지보호장치 회로의 DC 동작전압 최적조건 고찰)

  • Choi, Jong-Min;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.92-98
    • /
    • 2012
  • It is made compulsory to install SPD for the purpose of protecting electric and electronic devices when an abnormal voltage such as lightning occurs to power line using power frequency of 60Hz. Recently, the high speed communication technology utilizing power line is receiving attention again as a communication technology for smart grid. The SPD influences the performances of power line communication when using SPD and power line communication system together. In order to improve the performance of power line communication, a proposed scheme for series connection of gas discharge tube to ZnO varistor was presented. This paper measured the impacts of series connection of GDT to SPD using ZnO varistor on the limit voltage of Class III SPD. This paper also presented the DC operating voltage of GDT which satisfies the limit voltage of power line communication system and SPD simultaneously.

Competitiveness Increasing Methods of Metropolitan Railway Shinbundang-line (신분당선 전철의 경쟁력 제고 방안)

  • Han, Woo-Jin;Park, Jeong-Soo
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1936-1942
    • /
    • 2009
  • Shinbundang-line is new Metropolitan Railway which was invested by private capital and is under construction for opening in 2010. Now Shinbundang-line pursues various innovation, for example, an express train which uses long distance of each station, and an unmanned operation. And it may be independent of existing metropolitan railway system from a viewpoint of line and fare system. So according to the present plan, Shinbundang-line will be not able to get sufficient demand because of weak connection with existing lines and monotonous function of the line. And it may be difficult to deliver various innovation which Shinbundang-line prepares to passengers. Hereupon, in this paper, I propose 3 methods for increasing competitive power of Shinbundang-line railway. First, making Shinbundang-line a trunk railway line of southern metropolitan area was proposed in relation to northern and southern extension of it. In addition connection with bus and light rail was discussed. Second, multipurpose usage of Shinbundang-line was proposed as express train and conventional passenger train in that line in addition to simple metropolitan railway. Finally, an effective operation method which Shinbundang-line must have was proposed from unmanned driving and fare system side. These methods can improve Shinbundang-line and then it will solve traffic congestion of southern metropolitan area effectively.

  • PDF

A Study on the Determination of Optimum Cycle Time for Assembly Line Balancing (Line Balancing을 위한 최적 Cycle Time의 결정방법)

  • 이근부
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.3 no.3
    • /
    • pp.35-39
    • /
    • 1980
  • Although the product line produces a large volume of goods in a relatively short time, once the product line is established there are numerous problems that arise in connection with this product line. One of these problems is the problem of balancing operations or stations in terms of equal times and in terms of the times required to meet the desered rate of production. The objective of line balancing is minimizing the idle time on the line for all combinations of work stations subject to certain restrictions. In general, there are two types of line-balancing situations : (1) assembly line balancing and (2) fabrication line balancing. Two approaches to the assembly line balancing problem have been used. The first assumes a filed cycle time and find the optimum number of work stations. The second approach to the assembly line balancing problem assumes the number of work stations to be fixed and systematically coverages on a solution which minimizes the total delay time by minimizing the cycle time. Here the cycle time is determined by the longest station time. In this paper, by using the second approach method, a general mathematical model, problem solutions, and computer program for the assembly line balancing problem is presented. Data used is obtained from the company which has been confronted with many problems arising in connection with their assembly line.

  • PDF

Measurement method of the signal transfer characteristic(S21) of the impedance transformer (임피던스 변환회로의 신호 전달특성(S21) 측정 방법)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1282-1289
    • /
    • 2019
  • In order to measure the transfer characteristic(S21) of the impedance transformer, two impedance transformers must be symmetrically connected. However, the transfer characteristic of two symmetrically connected impedance transformers is influenced by the length of the intermediate connection line. This paper theoretically examines closely the length of the intermediate connection line to obtain the accurate transfer characteristic of the impedance transformer. The electrical length of the intermediate connection line for obtaining the accurate transfer characteristic of the 4:1(50-Ω:12.5-Ω) impedance transformer is calculated about 45°. Using the calculated length of the connection line, The λ/4-microstrip impedance transformer is fabricated at 1 GHz to measure the transfer characteristic. The symmetrically connected impedance transformer is measured the reflection characteristic(S11) of -40.64dB and the transfer characteristic(S21) of -0.154dB at 0.980GHz. This value is approximately equal to the theoretical calculated 987MHz center frequency and -0.15dB transfer loss value of the λ/4-microstrip impedance transformer.