도시철도 변전소의 네트워크 기반 실시간 데이터 취득 시스템 구현 (Implementation of a Real-Time Data Acquisition System Based on Wireless Communication for Urban Rail Transit Substation)

  • 정호성;박영;김형철
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.71-76
    • /
    • 2010
  • This paper is focused on implementing a real-time data acquisition system that checks power facility status by applying network based technology to Urban Transit substation power facilities and the results of its on-field tests. This system is composed of a sensor part, a measurement part, a transceiver part, a host computer, and a power source part. The system is designed to collect, save, analyze, and display the online state power facility AI (Analog Input). This system measures voltage and current from positive feeders and negative feeders where it is possible to check abnormalities of the substation‘s main power facilities. By monitoring abnormal data of the Urban Transit power facilities real-time and analyzing stored data, establishing procedures of optimized maintenance is possible.

변전자동화 종합 성능시험을 위한 시험모델 및 설계시스템 개발에 관한 연구 (A Study on the Development of Testing Models and Its Design System for the Comprehensive Performance Test of the Substation Automation System)

  • 이남호;장병태
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.63-71
    • /
    • 2011
  • Due to the rapid development of digital technnology and informantion communication, in the IEC 61850 based substation automation system, the innovative paradigm shift is expected and also required in many substation-related jobs, especially in the device function test area Accordingly a common testing model which can simplify the complex contents of the SAS performance test performed by test engineers has been identified, that can overcome limitations of engineers' own testing knowledge and experience. Testing models and its design system for the comprehensive performance test of the Substation Automation System is developed and the result of the study is reported in this paper.

IEC61850기반 변전소 자동화에 필요한 스위치 이더넷 네트워크 설계 (The Design of Switched Ethernet Network for IEC61850-based Substation Automation)

  • 김병진;이진;황보승욱;김정수;김희수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.70-71
    • /
    • 2006
  • IEC61850 which has comes to international standard for substation automation is designed with a station and process bus communication with Ethernet. In this paper, mentioning difference between official networks and substation networks, authors present the requirements for temperature, humidity and EMI characteristics. The properties which network switch should be satisfied and the technologies which make those requirements possible are also proposed. Additionally, we analysis the traffic pattern of communication services which IEC61850 supports. Based on the pattern, we propose a practical design example of IEC61850 based network for a 154kV substation.

  • PDF

IEC 61850 기반 IED의 XML을 이용한 트립로직 구성 (The Configuration Method of trip logic for IEC 61850 based IED using XML)

  • 고철진;진용우;김경택;김진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.315-316
    • /
    • 2006
  • As IEC 61850 based substation automation technology is emerging globally, there are many efforts to implement and apply this IEC 61850 standard to substation automation area. IEC 61850 based substation supports ethernet network, standard data model and SCL(substation Configuration Language), etc. These features can provide enough environment to make applied technology which can substitute the legacy relay trip logic configuration method(PLC or Local area reconstruction) to XML based configuration method. This paper suggests new IED trip logic configuration method. The XML based trip logic configuration method can be established using SCL technology And IED trip logic reconfiguration from remote center can be possible under ethernet based technology

  • PDF

IEC 61850 기반의 디지털 변전소를 위한 통신 드라이버에 관한 연구 (A Study on Communication Driver for Substation Automation based on IEC 61850)

  • 이일화;최철환;한진희;전태영;신용학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.111-113
    • /
    • 2006
  • Substation automation is one of the key issues for the enhancement of the power industrial foundation. IEC 60850 is an international standard specifying communication network and systems in substation. It supports interchangeability and interoperability of equipments from different vendors. ACSI(Abstract communication service interface) specifies basic communication structure for substation and IEDs. It supports communication as well as various services without proper protocols. For actual communication, MMS(Manufacturing Message Specification : ISO 9506) is used to map ACSI services. Solutions for the development of communication driver based don IEC 61850 are proposed in this paper.

  • PDF

코호넨 신경회로망을 이용한 ULTC 변압기와 STACOM의 협조제어 (Coordination Control of ULTC Transformer and STACOM using Kohonen Neural Network)

  • 김광원;이흥재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권9호
    • /
    • pp.1103-1111
    • /
    • 1999
  • STACOM will be utilized to control substation voltage in the near future. Although STACOM shows good voltage regulation performance owing to its rapid and continuous response, it needs additional reactive power compensation device to keep control margin for emergency such as fault. ULTC transformer is one of good candidates. This paper presents a Kohonen Neural Network (KNN) based coordination control scheme of ULTC transformer and STACOM. In this paper, the objective function of the coordination control is minimization of both STACOM output and the number of switchings of ULTC transformer while maintaining substation voltage magnitude to the predefined constant value. This coordination, control is performed based on reactive load trend of the substation and KNN which offers optimal tap position in view of STACOM output minimization. The input variables of KNN are active and reactive power of the substation, current tap position, and current STACOM output. The KNN is trained by effective Iterative Condensed Nearest Neighbor (ICNN) rule. This coordination control applied to IEEE 14 bus system and shows satisfactory results.

  • PDF

배전선로 상시연계점 측정 전압 위상차를 이용한 변전소 모선 위상각 추정 방법 (Substation Bus Voltage Angle Calculation Method Using Voltage Angle Difference Measured at the Tie Switch in the Distribution Line)

  • 손주환;임성일
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.9-15
    • /
    • 2016
  • Distribution networks are operated in radial fashion during the normal state. Loop configuration is also required temporally in case of live load transfer among the adjacent feeders. Voltage angles of each substation buses are very important data in order to calculate power flow of the loop structured distribution feeders. This paper proposes substation bus voltage angle calculation method using voltage angle difference measured at the normally open tie switches. Simulation case studies using Matlab simulink have been performed to establish feasibility of proposed method.

지중변전실 하부통과를 위한 터널설계 및 시공사례 (A Case on Design and Construction of Tunnel for Under Passing an Underground Transformer Substation)

  • 정동호;문상조;김선홍;이광제;석진호
    • 화약ㆍ발파
    • /
    • 제19권1호
    • /
    • pp.11-18
    • /
    • 2001
  • This is a case history on design and cnostruction of tunnel for under passing an underground transformer substation. The original construction plan was cut & cover method to avoid blasting vibrations and displacements of facilities during the construction stages. But this plan was changed to tunnel because of the difficulties from construction period, cost and the required relocation site. As a results of tunnel construction, the relocation of transformer substation and replacements of transmission cables were not necessary. Therefore about 10 months of construction period and 3.5 billion wonts of construction cost were saved. Additionally, quantitative criterion for blasting was provided through the results of blasting vibration analysis.

  • PDF

변전소 상태변수 추정에 관한 연구 (A Study on the State Estimation of a Substation)

  • 이흥재;김용한;박성민;강현재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.270-272
    • /
    • 1999
  • As the power system automation, especially the substation automation is currently a major issue, it has been widely studied. Since a measured value usually has an error that results in the communication process and the characteristics of a measurement device mainly depending on the reliability. The accuracy and reliability of measured values at a substation is an important factor for substation automation. In this paper, a state estimation algorithm is proposed for domestic 154kV/22.9kV distribution substations, and the results showed promising application.

  • PDF

154kV 변전소에서 피뢰장치의 뇌서지특성 해석 (A Study on the Analysis of the Lightning Surge Characteristics of Arresters in a 154kV Substation)

  • 윤창섭;조한구;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권10호
    • /
    • pp.433-439
    • /
    • 2006
  • This paper describes the characteristic evaluation of 154kV lightning arrester developed by domestic technology. To prove the protective ability of lightning arrester developed, various overvoltages were analyzed for A and B arrester were being used now at 154kV air and gas insulation substation, and for arrester developed. The results obtained by the various simulations show that the developed arrester has the effective protective ability and reducing ability of the overvoltage as A and B arrester, nevertheless there are somewhat differences among three kinds of arresters. Accordingly, it is evaluated that the arrester developed by domestic technology secured reliability can be installed actually at 154kV substation. In this paper, EMTP/ATP was used for simulation.