Issues Related to the Modeling of Solid Oxide Fuel Cell Stacks

  • Yang Shi;Ramakrishna P.A.;Sohn Chang-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.391-398
    • /
    • 2006
  • This work involves a method for modeling the flow distribution in the stack of a solid oxide fuel cell. Towards this end, a three dimensional modeling of the flow through a Solid Oxide Fuel Cell (SOFC) stack was carried out using the CFD analysis. This paper examines the efficacy of using cold flow analysis to describe the flow through a SOFC stack. It brings out the relative importance of temperature effect and the mass transfer effect on the SOFC manifold design. Another feature of this study is to utilize statistical tools to ascertain the extent of uniform flow through a stack. The results showed that the cold flow analysis of flow through SOFC might not lead to correct manifold designs. The results of the numerical calculations also indicated that the mass transfer across membrane was essential to correctly describe the cathode flow, while only temperature effects were sufficient to describe the anode flow in a SOFC.

Material technique of high temperature fuel cell(MCFC SOFC) (고온형 연료전지의 재료 기술)

  • 김귀열;엄승욱;윤문수
    • Electrical & Electronic Materials
    • /
    • v.5 no.3
    • /
    • pp.265-269
    • /
    • 1992
  • 미국의 ERC는 용융탄산염형 연료전지의 연구개발을 연방 에너지성의 지원하에 100KW stack의 개발을 진행시키고 있으며 Pacific gas & Electric com.는 100KW stack 운전시험에 성공하면 2MW의 실증 P1-ant를 발주할 게획이다. 그리고 일본은 신에너지 산업기술 총합 개발 기구(NEDO)의 project인 1MW발전 system 개발을 목표로 100KW를 stack 개발, 1MW급 Plant 구성기기 기술 system 기술 개발 진행중에 있으며 '93년에 100KW급 stack의 중간평가 실시와 '93-'94년 1MW급 발전 system의 설계, 건설, 운전 시험을 계획중에 있다. 한편 고체 전해질형 연료전지는 국외에서 1.3KW급 발전에 성공하였으며 10-20KW급 연구 개발이 진행중이다. 따라서 국내에서는 차세대 연료전지인 MCFC와 SOFC에 대하여 많은 노력에 의해서 선진국 기술 수준에 접근하므로서 실용화가 가능하리라고 본다.

  • PDF

Development of Cylindrical Capacitive-Conductive Sensor to Evaluate Insulating Degradation for FCEV Stack (차량용 연료전지 스택의 절연열화 진단을 위한 원통형 정전용량-전기전도도 센서개발)

  • Kim, Jae-Hoon;Kim, Ju-Han;Kim, Yoon-Hyung;Cui, Jiang-Yue;Han, Sang-Ok;Yong, Gee-Joong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.317-324
    • /
    • 2010
  • It was used as measuring system to diagnose insulating condition, by which was kept a insulating resistance of inner stack and at the same time was cooled electrochemical heat of reaction of FCEV(fuel cell electric vehicle) stack that used a compressed hydrogen gas reacting with oxygen in accordance with variation on thermal degradation of nonconductive heat transfer fluid. Consequently it was developed a cylindrical multi-terminal capacitive-conductive sensor that could be attached to the internal surface of cooling system pipe to evaluate capacitance and conductivity of heat transfer fluid.

p-STACKS ON SUPRATOPOLOGICAL SPACES

  • Min, Won-Keun
    • Communications of the Korean Mathematical Society
    • /
    • v.21 no.4
    • /
    • pp.749-758
    • /
    • 2006
  • In [1], we introduced the notion of p-stacks. In this paper, by using p-stacks we characterize $S^*-continuous$ functions, separation axioms, supracompactness and some properties on supratopological spaces. We also introduce the notion of p-supracompactness and study some properties.

Cycle Detection of Discrete Logarithm using an Array (배열을 이용한 이산대수의 사이클 검출)

  • Sang-Un Lee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.15-20
    • /
    • 2023
  • Until now, Pollard's Rho algorithm has been known as the most efficient way for discrete algebraic problems to decrypt symmetric keys. However, the algorithm is being studied on how to further reduce the complexity of O(${\sqrt{p}}$) performance, along with the disadvantage of having to store the giant stride m=⌈${\sqrt{p}}$⌉ data. This paper proposes an array method for cycle detection in discrete logarithms. The proposed method reduces the number of updates of stack memory by at least 73%. This is done by only updating the array when (xi<0.5xi-1)∩(xi<0.5(p-1)). The proposed array method undergoes the same number of modular calculation as stack method, but significantly reduces the number of updates and the execution time for array through the use of a binary search method.

Ku-Band Three-Stack CMOS Power Amplifier to Enhance Output Power and Efficiency (출력 전력 및 효율 개선을 위한 3-스택 구조의 Ku 대역 CMOS 전력 증폭기)

  • Yang, Junhyuk;Jang, Seonhye;Jung, Hayeon;Joo, Taehwan;Park, Changkun
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.133-138
    • /
    • 2021
  • We propose a Ku-band three-stack CMOS power amplifier to enhance the output power and efficiency. To minimize the dc power consumption, the driver stage is designed using common-source structure. To obtain high output power and utilize a voltage combining method, the power stage is designed using stack structure. To verify the proposed power amplifier structure, we design a Ku-band power amplifier using 65-nm RFCMOS process which provide nine metal layers. The P1dB, power-added efficiency, and gain are higher than 20 dBm, 23 dB, and 25%, respectively, while the operating frequency is 14 GHz-16 GHz.

A Study on Performance of PEMFC with Variations on Stack Temperature and Mass Flow Rate (스택온도 및 유량변화에 따른 PEMFC의 출력특성 연구)

  • Park, Se-Joon;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.140-140
    • /
    • 2009
  • The polymer electrolyte membrane fuel cell(PEMFC) with the advantages of low-operating temperature, high current density, low cost and volume, fast start-up ability, and suitability for discontinuous operation becomes the most reasonable and attractive power system for transportation vehicle and micro-grid power plant in a household. 200W PEM-type FCs system was integrated by this study, then the electrical characteristics and diagnosis of the fuel cell were analyzed with variations on mass flow rate and stack temperature. The ranges of the variations are $20{\sim}70^{\circ}C$ on stack temperature and 1~8L/min on $H_2$ volume.

  • PDF

On the Machinability of CFRP Composites Dependent on the Number of Stacking and Drill Diameter (CFRP복합재료의 적층수와 드릴직경에 관한 연구)

  • 정성택;박종남;조규재
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.8-13
    • /
    • 2003
  • CFRP composite has a lot of merits such as mechanical characteristic, light weight and thermal resistance. For these merits CFRP is applied to so many industrial area. In order for the composite materials to be used in the aircraft structures or machine elements, accurate surfaces for bearing mounting or joints must be provided, which require precise machining. In this paper, the relationship between the stack thickness and drill diameter is examined from the drilling experiment, which is the drilling of 16, 32, 48p1ies specimen with the ${\phi}8$, ${\phi}10$, ${\phi}12mm$ cemented carbide drill. The results are analyzed with consideration of cutting force, stack thickness and drill diameter.

A Study of SCEs and Analog FOMs in GS-DG-MOSFET with Lateral Asymmetric Channel Doping

  • Sahu, P.K.;Mohapatra, S.K.;Pradhan, K.P.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.6
    • /
    • pp.647-654
    • /
    • 2013
  • The design and analysis of analog circuit application on CMOS technology are a challenge in deep sub-micrometer process. This paper is a study on the performance value of Double Gate (DG) Metal Oxide Semiconductor Field Effect Transistor (MOSFET) with Gate Stack and the channel engineering Single Halo (SH), Double Halo (DH). Four different structures have been analysed keeping channel length constant. The short channel parameters and different sub-threshold analog figures of merit (FOMs) are analysed. This work extensively provides the device structures which may be applicable for high speed switching and low power consumption application.

A Study on the Emission and Dispersion of Particulate Matter from a Cement Plant (한 시멘트공장의 분진발생과 대기확산에 관한 조사연구)

  • Chang, Man-Ik;Chung, Yong;Kwon, Sook-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.16 no.1
    • /
    • pp.67-77
    • /
    • 1983
  • To investigate the an air pollution by particulate matter and its dispersion, a cement plant produceing portland cement 600,000 ton/year and its vicinity were surveyed from Obtober, 1980 to April, 1983. The survey was mainly focused on main stack emmission rate of the cement plant and particle size distribution in the dust, dustfall and total suspended particulate concentration in the area by month and distance from the stack. The results of the study were as follows; 1. The main stack emission rate was surveyed before and after the spray tower was additionally installed to the original E.P bag filter. Before the spray tower installed, the main stack emission rate was higher ($0.64g/Nm^3$) than the emission standard of Korean Environmental Preservation Law's ($0.59g/Nm^3$, amended to $0.4g/Nm^3$ on April 1983), but after the spray tower was installed, its main stack emission rate was markedly decreased to the standard ($0.43g/Nm^3$). 2. $2{\sim}3{\mu}m$ of the particle size was the largest portion (20.8%) of the dust particulate from the main stack and 50% of the frequency distribution was $1.5{\mu}m$ of the size. Most particle size was below $10{\mu}m$. 3. The spray tower reduced the dustfall to $37.81{\sim}9.76\;ton/km^2/month$ while dustfall appeared at $45.29-15.45ton/km^2/month$, in the vicinity of plant before spray tower installed 4. Mean concentrations of total suspended particulate for 24 hours of the various stations were determined in $20.6-200.0{\mu}g/m^3$, 3 stations of tham were higher than the value of Harry and William's arthmetic average standard $130{\mu}g/m^3$. 5. Linear regression between dustfall [X] and total suspended particulate[Y] concentration was an equation, Y=4.024X+11.479.[r=0.91] 6. During the whole seasons in the opposite area 100m apart from the omission source the prevailing wind direction was with estimated more than $30ton/km^2/month$, and the concentration of total suspended particulate for 24 hours averaging time was more than $140{\mu}g/m^3$ in the same area and direction. 7. Assuming the wind direction were constant through the day dustfalls for a day were estimated at $13.40ton/km^2/day,\;10.79ton/km^2/day$ and $4.55ton/km^2/day$ at various distances of 100m, 500m and 1,500m from the emission source respectively. 8. In the simutalion of dustfall and suspended dust by area, Gaussian dispersion model modified by size distribution of particulate matter was not applicated since the emission of dust were from multi sources other them stack. From the above results, it could be applied that the dispersion of dust from the cement plant is estimated and regulated for the purpose of environmental protection.

  • PDF