• Title/Summary/Keyword: interconnected

Search Result 1,155, Processing Time 0.023 seconds

Finite Element Vibration Analysis of Multiply Interconnected Structure with Cyclic Symmetry (순환대칭으로 다중연결된 구조물의 유한요소 진동해석)

  • 김창부;안종섭;심수섭
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.637-644
    • /
    • 1997
  • In this paper, a method of finite element analysis is presented for efficient calculation of vibration characteristics of not only simply interconnected structure with cyclic symmetry but also multiply interconnected structure with cyclic symmetry by using discrete Fourier trandform by means of a computer with small memory in a short time. Simply interconnected structure means it is composed of substructures which are adjacent themselves in circumferential direction. First, a mathematical model of multiply interconnected structure with cyclic symmetry is defined. The multiply interconnected structure is partitioned into substructures with the same goemetric configuration and constraint eqauations to be satisfied on connecting boundaries are defined. Nodal displacements and forces are transformed into complex forms through discrete Fourier transform and then finite element analysis is performed for just only a representative substructure. In free vibration analysis, natural frequencies of a whole structure can be obtained through a series of calculation for a substructure along the number of nodal diameter. And in forced vibration analysis, forced response of whole structure can be achieved by using inverse discrete Fourier transform of results which come from analysis for a substructure.

  • PDF

Optimization of ride comfort for a three-axle vehicle equipped with interconnected hydro-pneumatic suspension system

  • Saglam, Ferhat;Unlusoy, Y. Samim
    • Advances in Automotive Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-20
    • /
    • 2018
  • The aim of this study is the optimization of the parameters of interconnected Hydro-Pneumatic (HP) suspension system of a three-axle vehicle for ride comfort and handling. For HP suspension systems of equivalent vertical stiffness and damping characteristics, interconnected HP suspension systems increase roll and pitch stiffness and damping characteristics of the vehicle as compared to unconnected HP suspension systems. Thus, they result in improved handling and braking/acceleration performances of the vehicle. However, increased roll and pitch stiffness and damping characteristics also increase roll and pitch accelerations, which in turn result in degraded ride comfort performance. Therefore, in order to improve both ride comfort and vehicle handling performances simultaneously, an optimum parameter set of an interconnected HP suspension system is obtained through an optimization procedure. The objective function is formed as the sum of the weighted vertical accelerations according to ISO 2631. The roll angle, one of the important measures of vehicle handling and driving safety, is imposed as a constraint in the optimization study. Upper and lower parameter bounds are used in the optimization in order to get a physically realizable parameter set. Optimization procedure is implemented for a three-axle vehicle with unconnected and interconnected suspension systems separately. Optimization results show that interconnected HP suspension system results in improvements in both ride comfort and vehicle handling performance, as compared to the unconnected suspension system. As a result, interconnected HP suspension systems present a solution to the conflict between ride comfort and vehicle handling which is present in unconnected suspension systems.

Effect of Interconnected Boundary Between Journal and Thrust Bearings on the Performance of Self-Acting Air-Lubricated Bearings (저널-스러스트 베어링 사이의 상호 연결 경계가 동압 공기 윤활 베어링의 성능에 미치는 영향)

  • Kang, Ji-Hoon;Kim, Sung-Ki;Kim, Kyung-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.608-613
    • /
    • 2003
  • In this paper, the effect of interconnected boundary between journal and thrust bearings on the performance of self-acting air-lubricated bearings is investigated. When journal and thrust bearings have common boundary, conventional boundary condition which assumes that the boundary pressure is equal to atmosphere is no more valid. Instead, new boundary condition by mass conservation at interconnected boundary is needed. To do this, a duct model satisfying mass conservation at interconnected boundary is developed. Using this model, pressure distribution at interconnected boundary is numerically analyzed with changing the volume of interconnecting part. As a result, it is shown that load capacity of thrust bearing can be greatly increased when journal and thrust have a common boundary.

Decentralized Output Feedback Robust Passive Control for Linear Interconnected Uncertain Time-Delay Systems

  • Shim, Duk-Sum
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.2
    • /
    • pp.140-146
    • /
    • 2002
  • We consider a class of large-scale interconnected time delay systems and investigate a decentralized robust passive control problem. sufficient conditions for unforced interconnected uncertain systems with time delay to be robustly stable with extended strictly passivity is given in terms of algebraic Riccati inequality and linear matrix inequality. The decentralized robust passive control problem for norm-bounded and positive real uncertainty is shown to be converted to extended strictly positive real control problem for a modified system which contains neither time delay nor uncertainty.

The Study on Protective Coordination of Utility Interconnected Multiple Distributed Generations (다수 분산전원 연계시 계통측 보호협조에 관한 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul;Lee, Bong-Yi
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.233-235
    • /
    • 2004
  • This paper studies protective coordination of utility interconnected multiple distirbuted generations(DG). The study of protective coordination interconnected DG has been conducted. A protective coordination of utility disturbed by reverse current of DG. Therefore, A protetive device is not operate when reverse current flows. In this paper, we use phase difference between V and I. Also, we studied protective coordination algorithm of utility interconnected multiple DG.

  • PDF

Decentralized Output-feedback Stabilization of Linear Time-invariant Interconnected Systems with Delays

  • Shim, Duk-Sun
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.2
    • /
    • pp.158-162
    • /
    • 1998
  • We study the decentralized stabilization problem of linear time-invariant large-scale interconnected systems with delays without any system structure. We obtain sufficient stability conditions for interconnected systems which are equivalent to disturbance attenuation of some scaled system. A decentralized output-feedback controller is obtained using standard H$\infty$ control theory. The obtained controller is delay-independent. We also obtain an observer for the interconnected system.

  • PDF

Operational Problems Expected in Interconnected Power Systems (연계된 계통에서 예상되는 문제점)

  • Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.122-125
    • /
    • 1992
  • Political situations of Korean Peninsula has been changing dramatically in recent years. Interconnected power system operation between South and North Korea should be taken into considerations. This paper discusses several expected operational problems in interconnected systems through literature study. Typical references in automatic generation control area are listed and recommended to read through.

  • PDF

Fuzzy Output-Feedback Controller Design for PEMFC: Discrete-time Nonlinear Interconnected Systems with Common Inputs Approach (고분자 전해질 연료전지 시스템의 퍼지 출력 궤환 제어기 설계: 공통 입력을 갖는 이산시간 비선형 상호결합 시스템 접근)

  • Koo, Geun-Bum;Park, Jin-Bae;Joo, Young-Hoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.9
    • /
    • pp.851-856
    • /
    • 2011
  • In this paper, the fuzzy output-feedback controller is addressed for a discrete-time nonlinear interconnected systems with common input. The nonlinear interconnected system is represented by a T-S (Takagi-Sugeno) fuzzy model. Based on T-S fuzzy interconnected system, the fuzzy output-feedback controller is designed with common input. The stability condition of the closed-loop system is represented to the LMI (Linear Matrix Inequality) form. PEMFC model is given to show the verification of the controller discussed throughout the paper.

Robust Stabilization of Decentralized Dynamic Surface Control for a Class of Interconnected Nonlinear Systems

  • Song, Bong-Sob
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.2
    • /
    • pp.138-146
    • /
    • 2007
  • The analysis and design method for achieving robust stabilization of Decentralized Dynamic Surface Control (DDSC) is presented for a class of interconnected nonlinear systems. While a centralized design approach of DSC was developed in [1], the decentralized approach to deal with large-scale interconnected systems is proposed under the assumption that interconnected functions among subsystems are unknown but bounded. To provide a closed-loop form with provable stability properties, augmented error dynamics for N nonlinear subsystems with DDSC are derived. Then, the reachable set for errors of the closed-loop systems will be approximated numerically in the form of an ellipsoid in the framework of convex optimization. Finally, a numerical algorithm to calculate the $L_2$ gain of the augmented error dynamics is presented.

A study on comparative analysis of direct current control in A.C.-D.C. interconnected power system (교류-직류 연계계통에 있어서 직류제어방식의 비교연구)

  • 정형환;왕용필;안병철;이광우
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.474-483
    • /
    • 1996
  • In this paper, as a part of the method improving stability, the load-flow calculation in D.C. power system and the models for stability analysis are studied with A.C-D.C. interconnected power systems transmission performed. Moreover, the theory is established in relation to each control method of D.C. power systems. Then the stability of A.C-D.C.interconnected power systems is compared and considered by the way of dividing the operating control method of the rectifier inverter converter into ACR-AVR, APR-A.gamma.R, A.alpha.R-ACR. The dynamics characteristic of terminal voltage, frequency, active-reactive power and rotor angle of the generator with disturbances and load fluctuations is considered. In addition, the characteristic of direct voltage, direct current, power and control systems. From this the comparative analysis of the direct current control method, the possibility of the stability analysis of A.C.-D.C. interconnected power system is considered. (author). refs., figs., tabs.

  • PDF