A Study on Performance Requirement of I/Q Impairments for RF Implementation in W-CDMA User Equipment (W-CDMA 사용자장치 RF 구현을 위한 I/Q 열화성능요구규격 연구)

  • Lee, Il-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.148-154
    • /
    • 2005
  • This paper deals with performance degradations caused by RF I/Q impairments such as amplitude mismatch and phase mismatch in W-CDMA user equipment which uses QPSK(Quadrature Phase Shift Keying) modulation. The impacts of I/Q impairments on the BER(Bit Error Rate) are analyzed by using the variations of adjacent symbol distance. The BER versus amplitude mismatch and phase mismatch with QPSK constellation is reviewed through Matlab simulation. Performance degradation produced by RF I/Q impairments is measured with the implemented RF transceiver and modulation/demodulation test equipments through EVM(Error Vector Magnitude). The minimum performance requirements of amplitude mismatch and phase mismatch in W-CDMA user equipment are presented from the point of hardware implementation and the test method of the impairments is also included.

A Resonance Inverter Power System for Improving Plasma Sterilization Effect (플라즈마 살균효과 향상을 위한 공진형 인버터 전원시스템)

  • Suh, Ki-Young;Mun, Sang-Pil;Jung, Jang-Gun;Kim, Ju-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.135-141
    • /
    • 2004
  • A sterilizer equipment by using electrical energy has metrits that no process of chemical and no second environmental pollution, Also, the power conversion circuit for sterilizer equipment has mertis that are reducing switching loss for soft switching topology by using zero current and zero voltage switching, and miniaturizing size of equipment. The proposed power device which has lower output current than other devices is possible to be compacted in it's size reduced it's price if the proposed power device is used for power system. Therefore, it is adapted for both less power consumption and sudden power conversion

Investigation of Simulation and Measuring Algorithm of Partial Discharge for Diagnosis of Electric Machinery Deterioration (전력기기 열화 진단을 위한 부분방전 모의 및 측정 알고리즘 개발연구)

  • Jang, Hyeong-Taek;Kwack, Sun-Geun;Shin, Pan-Seok;Kim, Chang-Eob;Chung, Gyo-Bum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.30-38
    • /
    • 2011
  • This paper proposes a new intelligent diagnosis equipment for the partial discharge, which keeps deteriorating the insulating materials inside electric machineries, ultimately leading to electrical breakdown. In order to simulate experimentally the partial discharge inside the electric machinery, the tip-to-plate, the sphere-to-plate, the sphere-to-sphere and the plate-to-plate electrodes are used respectively, of which the gaps are 1[mm], 3[mm] or 5[mm] and the applied voltages are 3[kV], 5[kV] or 7[kV]. Ceramic coupler sensor and FIR digital filter are used to measure the partial discharge and the artificial neural network is used for the deterioration diagnosis of the electric machinery. The microprocessor of PD diagnosis equipment is DSP (TMS320C6713) with FPGA (Cyclone II). The results of the real-time and on-line experiments performed with the developed equipment are also explained.

The Research in Rationalization of the use of Energy in Electric Power (에너지 이용 합리화를 위한 전기에너지 사용계획 수립에 관한 연구)

  • Kim, Man-Kook;Nam, Si-Bok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.66-74
    • /
    • 2009
  • This study investigated and analyzed electrical energy curtailment effect by each business department and by energy use efficiency elevation equipment because do an energy use plan that is enforced in each variety business that is developed in domestic by model. When plan the recent electrical energy use with this, I wish to contribute in energy use general planning establishment improvement that is aiming energy efficiency improvement newly by groping improvement plan moment deduce problem. Specially, search present condition and problem by electrical energy curtailment equipment application that probes mass and analyzed, and is applied in present our country according to analysis contents to the latest energy use plan that was enforced on energy use rationality narration but allowed purpose.

Transient Overvoltages of Communication Equipment Depending on the Grounding Method of SPD (SPD 접지방식에 따른 통신기기의 과도위험전압)

  • Eom, Ju-Hong;Lee, Tae-Hyung;Cho, Sung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.130-138
    • /
    • 2008
  • The tendency of lightning surge to propagate is a eared variously depend on the power system and subject equipment of protection. However, looking into the subject equipment with the lightning surge, the invasion route of lightning surge can be divided in between the two lines of power, between the power line and the ground, the power line and the PE conductor, between the neutral line and the ground and the like. In addition, in the event of the communication equipment, there exists the route of lightning surge incoming from between the communication lines, the communication line and the ground in addition to the power lines. In this study, the tendency of propagation of lightning surge penetrated on to the subject equipment is analyzed through the empirical experiment in accordance with the ground method by using the independent ground, common ground and bypass arrester ground for safety improvement in power lines.

Countermeasures for Flood Protection of Power Facility at Substation and Ground (수변전실 및 지상 전력기기 침수방지 대책에 관한 연구)

  • Kim, Gi-Hyun;Choi, Myeong-Il;Bae, Suk-Myong;Lee, Jae-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.78-84
    • /
    • 2008
  • Inundation of substation and ground power equipment broke out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical facility. So we researched the installation situation of substation and power equipment and inundation loss at Flood Danger Area. And we analyzed refutation or law relating to the flood protection counterplan of US, England Australia. We present flood protection countermeasures by survey and analyzing the internal standard and his paper will be used to resent a reform proposal of electrical feinted law about flood protection.

The Research for Malfunction and Installation Status of Power Quality Counterplan Equipment of Elevator (엘리베이터의 전원품질용 기기 설치 현황 및 오동작에 관한 조사)

  • Kim, Gi-Hyun;Yi, Geon-Ho;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.107-113
    • /
    • 2006
  • The number of confine-disease for elevator increases every year and then sudden stop, error of level indication stand; those can bring to uneasiness of elevator passenger and malfunction accidents related life accident are increasing. So we researched power quality counterplan equipment(SPD, Filter, Reactor) at site elevator controller room and malfunctions of elevator movement. We could confirm installation of power quality counterplan equipment recently and unchanging the number of malfunction. This data will be used the analysis for mutual relation between Power Quality(Sag, Interruption, ESD, ect.) and malfunction of elevator movement by testing the elevator equipment with EN12016(2004) and IEC standard level.

Calculation of the Harmonic Emission Limit for low-Voltage Electrical Equipment (국내 저압 전기기기의 고조파 유출 제한값 산정)

  • Kang, Moon-Ho;Song, Yang-Hoi;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.56-61
    • /
    • 2008
  • Because the harmonic disturbance characteristic which makes voltage drop and the deterioration of instantaneous power quality in electrical power system overheats the NGR and the customer capacitor and malfunctions the OCGR and AMR, it is necessary for electric power company to take active measures to reduce this disturbance. International Electrotechnical Commission(IEC) 61000-3-2 specifies limits for harmonic current emissions generated by low voltage(LV) electrical equipment whose input current $\leq$ 16(A) per phase. Analysis shows that limits for Class A equipment in IEC are calculated using the reference impedance of LV system and maximum permissible voltage and limits for other Classes are also calculated based on limits for Class A. Therefore we have calculated four(4) internal limits for LV electrical equipment using the korea reference impedance and maximum permissible voltage in this paper.

A Study on the Analysis of Efficiency for Underground Distribution Equipment by Installment Ways (지중배전공사에 설치되는 기기의 설치위치에 따른 영향 분석에 관한 연구)

  • Kim, Joon-Eel;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.83-89
    • /
    • 2009
  • The environment of electrical power industry is now faced on problems such as electric rates, an increasing sensitivity in society with environmental issues and energy factors. Up to now, reliability is greatly influenced by maintenance and environmental factors that are unique to the electric utilities. The reliability is a characteristic assigned to the electric power systems's function which is related to the concept of installment of equipment. Therefore this reports's key finding is that it is important that the utilities track their individual components' value over investment expense of their installed components. This can be accomplished to consider the cases of foreign electric power companies and take into account the various possible installment ways of equipment in Korea. These results are expected to be used as a reference material for design underground distribution facilities and future applications.

A Study on Installation of Monitoring System of Wireless Power Transmission System (무선전력전송 시스템의 모니터링 시스템 구축에 관한 연구)

  • Song, Young-Sang;Han, Woon-Ki;Jung, Jin-Soo;Lim, Hyun-Sung;Cho, Sung-Koo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.47-53
    • /
    • 2015
  • The electrical safety and efficiency is the most important thing of the electric vehicle charging system. The prior system is contact charging system that is contacted directly by human. So, it has riskiness such as electric shock in the case of poor insulation or contact problems. To solve these safety issues and the convenience problems, a wireless power transmission system has been developed and is currently in trial operation. However, because high frequency is used in wireless power transmission system instead of commercial frequency, we need to apply protection measures concerning electric shock and equipment protection. Also, it should be accompanied by measuring efficiency for the effective operation of the wireless power transmission system. Therefore, we structured monitoring system in trial operation area of wireless power transmission system and applied decision algorithm for protection of human and equipment and economic operation of it.