DOI QR코드

DOI QR Code

A Study on Installation of Monitoring System of Wireless Power Transmission System

무선전력전송 시스템의 모니터링 시스템 구축에 관한 연구

  • 송영상 ;
  • 한운기 (한국전기안전공사 전기안전연구원 미래기술연구팀) ;
  • 정진수 (한국전기안전공사 전기안전연구원 미래기술연구팀) ;
  • 임현성 (한국전기안전공사 전기안전연구원 미래기술연구팀) ;
  • 조성구 (한국전기안전공사 전기안전연구원 미래기술연구팀)
  • Received : 2014.09.17
  • Accepted : 2015.03.11
  • Published : 2015.04.30

Abstract

The electrical safety and efficiency is the most important thing of the electric vehicle charging system. The prior system is contact charging system that is contacted directly by human. So, it has riskiness such as electric shock in the case of poor insulation or contact problems. To solve these safety issues and the convenience problems, a wireless power transmission system has been developed and is currently in trial operation. However, because high frequency is used in wireless power transmission system instead of commercial frequency, we need to apply protection measures concerning electric shock and equipment protection. Also, it should be accompanied by measuring efficiency for the effective operation of the wireless power transmission system. Therefore, we structured monitoring system in trial operation area of wireless power transmission system and applied decision algorithm for protection of human and equipment and economic operation of it.

Keywords

References

  1. KAIST, 'Complement and optimization of performance in power supply and pickup system', KAIA, 2012.10.
  2. Jin-Soo Jung, Woon-Ki Han, Chan-Um Park, Young-Sang Song, Hyun-Sung Lim, 'Study to Analyze the Grounding System in the 20kHz Power Installation', KIEE, Vol. 62, No. 9, pp. 1308-1212, 2013.09.
  3. Jin-Soo Jung, Woon-Ki Han, Chan-Um Park, Young-Sang Song, Hyun-Sung Lim, Min-Ho Cho, Ji-Yun Lyu, 'Analisys about the Earth Fault Characteristics in the Wireless Power Transmission System of the Electric Vehicle', KIEE, Vol. 28, No. 12. pp. 13-17. 2014.12.
  4. IEC 60038, 'IEC standard voltages', 2009.
  5. IEEE 519(1992) 'IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems'.
  6. Jin-Soo Jung, Woon-Ki Han, Hyun-Wook Moon, Chan-Urm Park, 'Analysis of Electrical Shock on 20kHz Electrical Utility', KIEE Spring Conference, pp261-263, 2012.4.
  7. Korea Electric Power Corporation, 'Rules And Rates for Electric Service', 2015.01.