• 제목/요약/키워드: fundamental unit

검색결과 434건 처리시간 0.025초

수재사 모릍의 Flow특성에 관한 연구 (An Experimental Study on the Flow Characteristics of Mortar use Quenched Blast-Furnace Slag)

  • 양범석;임남기;이영도;이종균;정란;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.215-222
    • /
    • 1997
  • Flow experimental on not to be solid mortar which use Quenched Blast-furnace Slag as a fine aggregate was carried out for basic research data about fundamental study of application possibility of Quenched Blast-furnace Slag as a fine aggregate. It gives following result. The substitution rate is inversely proportional to Flow and C/S-rate same that. The relation with W/C-rate augment appear proportional : in case of C/S-rate, 1:3 increasing degree is a half of sand mortar that. Consequencely, Quenched Blast-furnace Slag motar is a counteraction to Flow in as same water content per unit. But suitable substitution rate and C/S-rate influence a little to the mortar consistency. And that reason, if C/S-rate and substitution rate will be regulated when we mix the mortar with quenched Blast-furnace Slag. that will be economic mixture.

  • PDF

건축 복합방수공법의 최적성능에 관한 기초연구 (A Fundamental study on the Optimum Performance of the Architectural Hybrid Water-proofing Systems)

  • 임석호;임병훈
    • 한국건축시공학회지
    • /
    • 제5권2호
    • /
    • pp.123-130
    • /
    • 2005
  • The purpose of this study is to present the optimum performance of hybrid waterproofing technology, which is including material and construction method. Recently, Hybrid waterproofing technology is developed little by little in KOREA. But there is not any other criterion of performance and evaluation of this technology. So, It is needed that appropriate performance items is are settled urgently. This paper were obtained by the SPSS analysis. In this study the safety factor are more important performance of building waterproofing materials than durability comfortability and productivity. And results of this analysis showed that (1) safety performance consists of Fatigue resistance, Crack Control performance deterioration Processing of tensile performance, Compressive Strength test (2) comfortability performance consists of watertightness, bond performance (3) persistency performance consists of abrasion resistance, tensile performance, flexural strength (4) productivity performance consists of dimension, unit space weight.

강성 베어링형 밸런실 장치의 개발 (Development of a hard bearing type balancing machine)

  • 권이석;이동환;박중윤;홍성욱
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.773-777
    • /
    • 1994
  • This paper is devoted to the development and performance evaluation of a hard bearing type balancing machine for rigid rotors. The pedestals of the balancing machine are designed to be rigid to be rigid enough to enable the balancing to operate far below the fundamental critical speed. The force measuring method is implemented to the balancing machine. The forces due to unbalance are measured through load cell that are attached to the pedestals. A helical coupling is used for transmitting the driving force from an AC servo motor to the rotor to be balanced. The experimental results show that the current hard bearing type balancing machine can indicate the presence of unbalance beyond 1 .mu. m in specific unbalance unit. The limitation of the current balancing machine is due to the coupling that is likely to make inconsistent offset errors everytime the rotor is connected to the machine.

  • PDF

전동차 주행성능평가를 위한 데이터취득 및 분석 (Data Acquisition and Analysis for Running Performance Evaluation of the Electric Train)

  • 이강원;김명룡;백광선;심재복;창상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1099-1100
    • /
    • 2006
  • The running of the electric train are done by powering, breaking and coasting. Powering to start and accelerate the rolling stock means driving the three-phase electric induction motors controlled by VVVF inverters which are connected to overhead power line directly(DC) or indirectly(AC, DC/AC). Breaking is achieved by blending control which is the proportional combination between regenerative breaking of VVVF inverter and air pressure control of breaking operating unit(BOU). Therefore, Data obtained during two operation are very important items to evaluate the running performance of RS. This paper has investigated in real time data acquired from VVVF inverter and measured by pressure sensor directly connected to air breaking line(motor car and trailer car). By analyzing data in the region of time and frequency, fundamental methods for eavaluating the running performance of RS quantitatively and objectively have been suggested.

  • PDF

전력제어 반도체용 히트파이프 냉각기의 열전달 성능 연구 (A Study on Heat Transfer Performances of a Heat Pipe Heat Sink for Power Control Semiconductors)

  • 강환국;김재진;김철주
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.701-709
    • /
    • 2001
  • In this days, heat pipe heat sink has been widely applied to power controllers for railway substations to remove heat from power semiconductors(diodes or thyristors). The heat pipe heat sink consists of a aluminum heating block for mounting the thyristor, 2~3 heat pipes and large number of aluminum fins. The present study was to get fundamental informations of the structure, design parameters and heat transfer performances of heat pipe heat sink. Series of operational test for a unit with 3 heat pipes were performed and its heat flow circuit was analysed from the experimentally obtained data on wall temperature distribution. Total resistance was ranged 0.02~$0.03^{\circ}C$/W for a power range from 40W to400W. The time to get the steady state was approximately longer than 20 minutes, and overshooting was not occurred during start up operation.

  • PDF

2.5G SDH 전자파 감소용 저역통과필터 설계 (Design of Low Pass Filter to reduce EMI from 2.SG SDH system)

  • 이성원;김영범
    • 한국시뮬레이션학회논문지
    • /
    • 제10권4호
    • /
    • pp.21-30
    • /
    • 2001
  • In this paper, EMI measurement, the STGU simulation being conducted, filter design, its characteristics, and its implementation to the PCB, and finally test results are discussed. When the low pass filter was implemented within the STGU, the power of EMI decreased more than 20dBm. Finally, when TE and MTIE, two important quality measure in synchronous reference clock, was assessed, ITU-T G813 requirement was satisfied. EMI(Electromagnetic Interface) is a measure of electomagnetic radiation from equipment in the range of 10KHz to 3GHz, and can cause unexpected reactions of electronics/electrical equipment. In this study, for safe and stable communication operation, a STGU (System Timing Generation Unit), which is a 2.5G SDH System and a major EMI source, was employed to simulate electromagnetic interface. Using Open-Site test, the power of fundamental frequency of EMI of interest and its harmonics were measured. Also, a low pass filter at cut-off frequency of 2GHz was specifically designed for this study to minimize the effect of EMI between electronic components.

  • PDF

TTL 시뮬레이터의 콤파일러 설계에 관한 연구 (A Study on the design of the compiler for a TTL simulator)

  • 신철재;김용득
    • 대한전자공학회논문지
    • /
    • 제14권2호
    • /
    • pp.17-27
    • /
    • 1977
  • 본 논문에서는 특수 고적의 소형 전자계산기를 단일 뻐스선 방법에 의한 TTL 집적회로로 설계하였으며, 각 지령어의 길이를 16비트르 구성함으로써 더욱 간편한 콤파일러를 연구하였다. 또한 본 실험에서 160nsec의 기본 주기를 택함으로써, TTL IC의 동작시간에 따른 최적치와 기억소자의 악세스 타임이 같게 되었고, 구성 회로도 간단하게 만들어졌으며, 모두 프로그램도 만족하게 처리되었다.

  • PDF

Mini MAP 환경에서 MMS 상의 군 관리 네트워크 서비스 모듈 설계 (Design of Group Management Network Service Module on MMS in Mini-MAP Environment)

  • 김정호;이상범
    • 전자공학회논문지B
    • /
    • 제30B권4호
    • /
    • pp.21-26
    • /
    • 1993
  • Network systems are of fundamental importance in programmable device in industrial automation, as they essential in order to active group management of integration and coordination. In this papers,MMS implemented on the basis ISO specification for industrial environment. In the MMS-MAP, MMS is situated in the application layer and on the datalink layer. This implemented software was operated with network interface unit which was designed in group objects and service primitives for group management network model system. This function of designed module showed possibility of operation through group state diagram transition in the Mini-MAP environment.

  • PDF

한국 주거공간용어 변화에 대한 기초 연구 -문학작품에 나타난 용어를 중심으로- (A Fundamental Study on the Change of Korean Dwelling Space Terms)

  • 신화경;김대년;서귀숙;오혜경;최경실
    • 한국주거학회논문집
    • /
    • 제9권2호
    • /
    • pp.97-103
    • /
    • 1998
  • The purpose of this study is to scrutinize the change of Korean dwelling space terms, and confirm the value of literature as data for a study on dwelling space terms. The terms, which describe the dwelling space, were selected in 63 Korean literature. The terms about rooms, working spaces, space for physiology and hygienic, and storage spaces, were analyzed. The terms about rooms were classified by a constituent unit of traditional housing, location, size, function, and so on. Among them, the number of terms about function had increased more and more. These terms were changed by housing size, housing form, structure of house and household, family size, and so on. It was confirmed that literatures have utility values for a study on change of dwelling space terms. In next study, it is required to analyze the meaning and usage of Korean dwelling space terms, and to compare terms in floorplans with terms in literature.

  • PDF

CRT를 사용한 잉여수계 기수확장에 관한 연구 (A Study on the Extension of Base Using CRT in RNS)

  • 김용성
    • 정보학연구
    • /
    • 제5권4호
    • /
    • pp.145-154
    • /
    • 2002
  • 기수확장(Extension of Base)은 잉여수계(RNS:Residue Number System)에서 모듈리를 확장하기 위한 기본적인 방법이다. 잉여수계는 병렬성과 모듈간의 자리올림 수의 전달이 없는 장점을 갖지만, 기수확장 등에 의해 전체적인 시스템의 성능이 저항되며, 혼합기수 변환을 적용한 기존의 방법에서는 연산기의 크기는 감소하지만 연산속도가 저하되는 문제점을 갖는다. 그러므로, 본 논문에서는 CRT를 사용한 개선된 기수확장을 수행하여, 비교적 적은 크기이며, 속도가 향상된 기수 확장기를 설계할 수 있었다.

  • PDF