• Title/Summary/Keyword: engineering measurement

Search Result 16,937, Processing Time 0.043 seconds

Disc Tilt Error Measurement using Reconstructed Image Pattern for Holographic Data Storage (홀로그래픽 정보저장기기의 재생 이미지 패턴을 이용한 디스크 틸트 오차 측정)

  • Lim, Sung-Yong;Han, Cho-Lok;Kim, Do-Hyung;Yang, Hyun-Seok;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.8 no.2
    • /
    • pp.67-71
    • /
    • 2012
  • Page-oriented holographic data storage (HDS) is very sensitive to the tilt error. Therefore, tilt error should be measured and compensated. Especially, mechanical tilt measurement method cannot cope with tilt error measurement because photopolymer medium has shrinkage problem. Therefore, the method to solve this problem is using the reconstructed image which can represent both tilt and shrinkage effect. In this paper, we suggest disc tilt measurement algorithm using image pattern of retrieval data.

Development of a Sensor Chip for Phasor Measurement of Multichannel Single Tone Signals (다채널 단일톤 위상 측정칩 개발)

  • Kim, Byoung-Il;Hong, Keun-Pyo;Hwang, Jin-Yong;Chang, Tae-Gyu
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.497-500
    • /
    • 2005
  • This paper presents a design of a hybrid sensor chip which integrates an A/D converter module and a phase measurement module for measuring power line phase. Recursive sliding DFT based phase measurement module is designed using time shared multiplier which can reduce the size of SoC implementation. A/D converter is based on the sigma delta modulation in order to minimize the implementation space of the analog part and designed to obtain 8-bit resolution. Computer simulations and FPGA implementation are performed to verify hybrid sensor chip design. The hybrid sensor chip for 4-channel power line phase measurement is fabricated by using 0.35 micrometer CMOS process.

  • PDF

Low Frequency Noise Characteristics of the 180nm MOSFETs

  • Yoon, Young-Chang;Lee, Ho-Cheol;Kang, In-Man;Shin, Hyung-Cheol
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.861-864
    • /
    • 2005
  • Performing accurate and repeatable low frequency noise measurement is critical for modeling and simulation of flicker noise. Through the accurate and repeatable on-wafer measurement, low frequency noise characteristics of the 0.18 ${\mu}m$ n-MOSFETs are discussed. And on-wafer flicker noise measurement system is presented. The on-wafer measurement system consists of cascade probe station, low noise current amplifier (SR570), and dynamic signal analyzer (HP35670A).

  • PDF

Development of Tethered-Balloon Package System for Vertical Distribution Measurement of Atmospheric Aerosols (Tethered-Balloon Package System 개발 및 대기 에어로졸의 연직 분포 측정)

  • Eun, Hee Ram;Lee, Hong Ku;Lee, Yang Woo;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.253-260
    • /
    • 2013
  • For a vertical atmospheric aerosol distribution measurement, a very compact and light particle sampling package is developed. This package includes a compact optical particle counter (Hy-OPC), a light and small condensation particle counter (Hy-CPC), sensors (GPS, wind velocity, temperature, humidity), and a communication and system control board. This package is attached to He balloon and the altitude is controlled by a winch. Using this system the vertical particle size distribution was measured. The test results showed that the ground base atmospheric particle measurement result may be a lot different from that high above the ground.

A Technique for Vibration Measurement and Roundness Assessment of Rotating-axis using Camera Image (카메라 영상을 이용한 회전축 진동 측정 및 진원도 평가 방법)

  • Son, Ki-Sung;Jeon, Hyeong-Seop;Park, Jin-Ho;Park, Jong Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.2
    • /
    • pp.131-138
    • /
    • 2014
  • Vibration measurement of rotating shafts by installing sensors such as accelerometers or displacement sensors is costly and dangerous in some cases. As an alternative method, vibration measurement using camera images has been researched because sensor installation is not needed and displacement of a rotating shaft can be directly evaluated. This paper also suggests the enhanced technique applicable to the measurement of vibration of a large-scale rotating shaft. The concurrent methods based on camera images use marks, which are hardly applicable to rotating shafts. The proposed method measures vibration without any marks by evaluating shape errors. The working principle of the method is described and verified by a series of experiments.

Measurement of Rainfall Characteristics and Rain-Attenuation at 38 GHz in Worst Months Affected by El Nino Signal in 1998

  • Jang Won-Gyu;Choi Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.4
    • /
    • pp.189-192
    • /
    • 2005
  • The measurement of unique rainfall phenomenon and rain attenuation on 38 GHz terrestrial links at South Korea in 1998 is presented. It was one of the most severe rainfall years at the measured region due to increased EI Nino signal. The rainfall rate exceeded at $0.01\%$ was 97.4 mm/h during a worst month and annual rate was 63.5 mm/h. Experimentally measured results have been compared with some models and found that the rain attenuation by system level was underestimated by the existing prediction models. As it was measured only three months, further study and measurement of rainfall and rain attenuation in this region are needed for stable millimeter-wave system operation at all times.

Wireless Bio-signal Monitoring System (무선 생체신호 모니터링 시스템)

  • Kim, Do-Kyoung;Lee, In-Kwang;Cha, Eun-Jong;Kim, Kyung-Ah
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2055-2056
    • /
    • 2011
  • As rapid aging and high economic level, people are interested in their wellness. And it needs to examine the condition of their health constantly. Proposed device can measure bio-signal by connecting several measurement modules such as spirometric module, blood glucose measurement module, uro-flow measurement module and temperature measurement module. These modules can be chosen as occasion demands. In addition, developed user program enables patients to monitor bio-signal at their own place via the personal computer.

  • PDF

Static measurement of yield stress using a cylindrical penetrometer

  • Uhlherr, P.H.T.;Guo, J.;Fang, T.N.;Tiu, C.
    • Korea-Australia Rheology Journal
    • /
    • v.14 no.1
    • /
    • pp.17-23
    • /
    • 2002
  • A novel and simple method using a cylindrical penetrometer is being developed for the measurement of yield stress. The principle of this technique is based on the measurement of the static equilibrium of a falling penetrometer in a yield stress fluid. The yield stress is simply determined by a balance of forces acting on the penetrometer. The yield stress of Carbopol gels and $TiO_2$ suspensions has been measured using this method. The results are in reasonable agreement with the values from conventional methods. The effects of the dimensions and weight of the penetrometer have been examined. The long-term behaviour was also observed. No measurable creep was seen and equilibrium was found to be very quickly established. The cylindrical penetrometer technique promises to be a simple, quick and reliable static method for the measurement of yield stress.

Electrohydrodynamic Ink Jetting Monitoring based on Current Measurement (전류 측정을 이용한 수력학적 잉크젯 토출 모니터링)

  • Kwon, Kye-Si;Lee, Dae-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.4
    • /
    • pp.449-454
    • /
    • 2012
  • The method for spraying of liquid through an electrical filed has become a printing method since it can make very small droplet. To increase the reliability using the electro-hydrodynamic (EHD) jet printing, the jetting status needs to be monitored. Vision measurement techniques using high speed camera has been used to visualize the jet images. However, it requires image processing of a lot of images after image acquisitions. So, it is difficult to understand jet behavior such as jetting frequency, jet repeatability etc. In this work, a low cost electrical current measurement method was developed to measure electrical current from EHD jet printing. To verify the jetting monitoring capability of developed circuit, images from high speed camera were processed for comparison purpose.

Research of Detection Method for Cytotoxic Effects of Environmental Pollutants Using Atomic Force Microscopy (AFM) in HeLa Cells (원자현미경(AFM)을 이용한 환경오염물질에 노출된 HeLa 세포의 표면변화 연구)

  • Lee, Si-Won;Lee, Soo-Il;Choi, Jin-Hee
    • Environmental Analysis Health and Toxicology
    • /
    • v.23 no.1
    • /
    • pp.47-51
    • /
    • 2008
  • The toxicity of environmental pollutants was measured between a image of the surface topography in HeLa cells using atomic force microscopy for the possibility of toxic effect measurement and environmental monitoring. A image of the surface topography by AFM were estimated as toxic endpoints. The surface topography by AFM was observed a change of the cell surface in the environmental pollutants, but the standard of the measurement requires for the dose-effect degree. The overall results indicate that the possibility of measurement using AFM were confirmed a dose-effect degree related toxic effects, but it requres correlation between more various biomarker and AFM's measurements if the possibility of the toxic effect measurement was established.