• 제목/요약/키워드: closed filter

검색결과 227건 처리시간 0.027초

Derivation of Recursive Relations in Markov Parameter for the Closed-Loop Identification

  • Lee, Hyun-Chang;Byun, Hyung-Gi;Kim, Jeong-Do
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.335-339
    • /
    • 1998
  • This paper presents a closed loop identification algorithm in time domain. This algorithm can be used for identification of unstable system and for model validation of system which is difficult to derive analytical model. In time domain, projection filter, which projects a finite number of input output data of a system into its current space, is used to relate the state space model with a finite difference model. Then recursive relations between the Markov parameters and the ARX model coefficients are derived to identify the system, controller and Kalman filter Markov parameters recursively, which are finally used to identify the system, controller and Kalman filter gains. The NASA LAMSTF is used to validate the algorithms developed.

  • PDF

유전체 공진기 필터의 결합창 특성해석 (Analysis of Coupling Windows of the Dielectric Resonator Filter)

  • 김병욱;윤두일;윤상원
    • 한국전자파학회논문지
    • /
    • 제13권1호
    • /
    • pp.101-105
    • /
    • 2002
  • 본 논문에서는 결합창으로 결합을 구현한 유전체 공진기 필터의 결합창 특성을 해석하였다. 결합창의 특성을 결합계수로 표현하였으며, 간단한 표현식으로 유도하였다. 결합창의 크기를 변화시키면서 해석 방법을 적용하여 결합계수를 계산하였고, 측정결과와 비교하여 해석의 유효성을 증명하였다. 본 논문에서 제안한 방법은 적용이 간단할 뿐 아니라, 결합창의 제작 및 측정오차 범위에서 정확한 결과를 보였다. 본 논문에서 제안한 방법은 유전체 공진기 필터의 설계 및 유전체 공진기와 Varactor diode로 이루어지는 동조필터가 동조주파수 대역에서 일정한 통과대역폭을 가지기 위한 최적화된 결합창의 설계 적용이 가능하다.

Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석 (Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff)

  • 이준호;방기웅;홍성철
    • 대한환경공학회지
    • /
    • 제31권11호
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone은 높은 수면적부하율 운전이 가능하고, 구동부분이 없고, 운전 및 유지관리비가 적게 소요되어 미세입자물질제거에 효과적인 장치로 다양한 산업 분야에서 활용되고 있다. Hydrocyclone에 나선형 유입부를 통해 직각으로 유입되어 중력이 아닌 원심력에 의해 입자물질이 하부배출구로 분리되고 처리수는 vortex finder를 통해 배출된다. 입자분리에 hydrocyclone은 많은 장점을 가지고 있음에도 불구하고 도시지역 강우유출수 처리사례는 드문 실정이다. 본 연구에서는 변형된 hydrocyclone과 perlite 여재를 조합한 hydrocyclone filter (HCF)을 이용하여 강우유출수내 미세입자의 제거능을 분석하였다. 입자물질들은 인공입자들을 이용하여 강우유출수내 입자농도를 모의 실험하였다. 인공입자들을 물에 분산시켜 강우유출수를 재현하였는데 사용한 입자들은 이온교환 수지, 도로측구 퇴적물질, 상업지역 맨홀퇴적물질, 그리고 실리카겔 등이다. 하부배출부와 vortex finder 구조를 달리하여 HCFopen system과 HCF-closed system으로 구분하여 처리능을 분석하였다. HCF장치는 아크릴 수지를 이용하였는데 hydrocyclone의 직경은 120 mm이고 여과조의 직경은 250 mm이고 전체적인 높이는 800 mm로 제작하였다. 운전조건별 유입수 농도와 입경을 다양하게 적용하였고 SS와 COD농도를 분석하여 처리효율을 산정하였다. HCF-open system의 경우 운전 가능한 최대 수면적부하율은 700 $m^3/m^2$/day이었고 HCF-closed system의 경우 수면적부하율 1,200 $m^3/m^2$/day까지이다. HCF-open system 운전결과 HCFclosed system에 비교하여 평균 수면적부하율은 2배 이상 높게 운전이 가능하며 처리효율도 8~20% 이상 향상되는 것으로 분석되었다. 또한 유입수 SS농도가 높을수록 처리효율이 증가하며, 입경이 클수록 수면적부하율의 변화에 대한 처리효율의 영향이 적은 것으로 분석되었다. HCF-closed system의 실험을 통한 수면적부하율 변화에 대한 실리카겔입자의 제거 효율과 CFD입자추적기법을 이용한 예측 처리효율을 비교한 결과 CFD에 예측효율이 실제실험결과와 비교하여 다소 높게 나타나지만 처리효율의 경향은 매우 유사하게 나타나 CFD추적기법을 이용한 HDS유형 처리장치 설계 시 유용한 도구로 활용될 수 있을 것으로 판단된다.

Improved Modification of the Closed-Loop-Controlled AC-AC Resonant Converter for Induction Heating

  • Dhandapani, Kirubakaran;Sathi, Rama Reddy
    • ETRI Journal
    • /
    • 제31권3호
    • /
    • pp.298-303
    • /
    • 2009
  • A single-switch parallel resonant converter for induction heating is implemented. The circuit consists of an input LC-filter, a bridge rectifier, and a controlled power switch. The switch operates in soft commutation mode and serves as a high frequency generator. The output power is controlled via the switching frequency. A steady state analysis of the converter operation is presented. A closed-loop circuit model is also presented, and the experimental results are compared with the simulation results.

  • PDF

밀폐박스 상태의 가상 라우드스피커 매개변수 규명법 및 개선된 밀폐박스 모델링 (Parameters Estimation for Pseudo Loudspeaker attached to Closed-Box and Enhanced Closed-Box Modeling)

  • 박석태
    • 한국소음진동공학회논문집
    • /
    • 제17권10호
    • /
    • pp.983-992
    • /
    • 2007
  • It was proposed to identify Thiele Small Parameters for loudspeaker attached to closed-box using known dynamic mass of moving parts. Also, enhanced PSPICE circuit model for closed-box loudspeaker system was proposed to more accurately simulate real closed-box loudspeaker system. Frequency dependent parameters were used to model voice coil inductor. Acoustic pressure response curves and electrical impedance curves were simulated and investigated by PSPICE circuit model according to compensation filter's parameters. Finally, proposed method is expected to be utilized for identification of pseudo Thiele Small parameters of microspeaker.

주파수영역 오차함수의 모델링과 분석을 통한 제로위상 FIR 필터 설계 (Design of Zero-phase FIR Filters Through the Modeling and Analysis of A Frequency-domain Error Function)

  • 전준현
    • 한국통신학회논문지
    • /
    • 제36권7C호
    • /
    • pp.451-458
    • /
    • 2011
  • MAXFLAT(maximally flat) FIR필터 설계는 폐쇄형 솔루션을 제공하는 장점이 있으나 설계의 정확성을 위하여 평탄차수를 정확하고 효율적으로 결정하는 문제가 아직 남아 있다. 본 논문에서는 폐쇄형 솔루션에서 주파수영역 오차함수를 모델링하고 분석하므로 써 직접적이고 정확하게 평탄차수를 결정하는 방법을 제안하였다. 마지막으로 주피수영역 오차함수를 바탕으로 제안한 차단주파수와의 최소거리 방식이 기존의 Herrmann 방식에 비해 매우 정확하고 효율적이라는 것을 입증하였다.

주파수 영역에서 최대평탄과 하프대역 특성을 갖는 폐쇄형 QMF 필터들의 설계 (Design of Closed-Form QMF Filters with Maximally Flat and Half-Band Characteristics in the Frequency Domain)

  • 전준현
    • 대한전자공학회논문지SP
    • /
    • 제44권4호통권316호
    • /
    • pp.70-77
    • /
    • 2007
  • JPEG2000 국제표준에서는 QMF 왜곡을 갖지 않는 2가지 필터 쌍(pare)을 제시하였다. 그러나 사용된 QMF 필터들은 완만한 롤오프율을 갖을 뿐만 아니라 통과대역에서 리플(ripple)이 존재하고 비동등대역분할 구조를 갖는 치명적인 단점이 있다. 따라서 본 논문에서는 최대평탄 및 가파른 롤오프율(roll-off rate) 응답특성을 갖는 일반화된 폐쇠형 공식을 이용하여 하프대역 이득의 최대평탄 QMF 필터들을 제시하였다. 기존의 JPEG2000의 QMF 필터들과 제안된 최대평탄 QMF 필터들의 주파수 응답을 비교한 결과 제안된 QMF 필터들은 통과대역에서 리플이 없고, 개선된 롤오프율(roll-off rate) 및 중첩대역폭을 갖는 것을 확인하였다. 더욱이 제안된 최대 평탄 QMF 필터들은 저지대역 감쇠가 최대 200dB를 초과하는 응답 특성을 나타내었다.

${\gamma}$-FUZZY FILTER AND LIMIT STRUCTURE

  • Lee, Yoon-Jin
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1998년도 The Third Asian Fuzzy Systems Symposium
    • /
    • pp.219-224
    • /
    • 1998
  • We introduce the notion of ${\gamma}$-fuzzy filter and ${\gamma}$-limit structure to L-fuzzy point. We show that the category ${\gamma}$Lim of ${\gamma}$-limit spaces is a cartesian closed topological construct containing the category LFTop of stratified L-fuzzy topological spaces as a bireflective subcategory.

  • PDF

Robust Guaranteed Cost Filtering for Uncertain Systems with Time-Varying Delay Via LMI Approach

  • Kim, Jong-Hae
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제3권1호
    • /
    • pp.27-31
    • /
    • 2001
  • In this paper, we consider the guaranteed cost filtering design method for time-varying delay system with parameter uncertainties by LMI(Linear Matrix Inequality) approach. The objective is to design a stable guaranteed cost filter which minimizes the guaranteed cost fo the closed loop systems in filtering error dynamics. The sufficient conditions for the existence of filter, the guaranteed cost filter design method, and th guaranteed cost upper bound are proposed by LMI technique in terms of all finding variables. Finally, we give an example to check the validity of the proposed method.

  • PDF

모달필터 성능을 고려한 센서의 최적위치 (Sensor Placement in Structural Vibration Control For the Performance of Modal Filter)

  • 황재혁;김준수;백승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.308-315
    • /
    • 1997
  • In this study, the effect of modal filter error on the vibration control characteristics of flexible structures is analyzed for IMSC(Independent Modal Space Control), and optimal sensor placement in the structural vibration control with consideration of performance of modal filter has been studied. An Lyapunov asymptotic stability condition has been derived, which depends on the magnitude of the modal filter errors. The extent of the response deviation of the closed-loop system is also derived and evaluated using operator techniques. A sensor placement technique has also been suggested to maximize the performance of the modal filter. It has been found by a series of simulation that the suggested sensor placement technique is very effective on the determination of the number and placement of sensors of modal filter in the structural vibration control.

  • PDF