• Title/Summary/Keyword: Water adsorption

Search Result 1,592, Processing Time 0.026 seconds

Adsorptive and kinetic studies of toxic metal ions from contaminated water by functionalized silica

  • Kumar, Rajesh;Verma, Sunita;Harwani, Geeta;Patidar, Deepesh;Mishra, Sanjit
    • Membrane and Water Treatment
    • /
    • v.13 no.5
    • /
    • pp.227-233
    • /
    • 2022
  • The objective of the study, to develop adsorbent based purifier for removal of radiological and nuclear contaminants from contaminated water. In this regard, 3-aminopropyl silica functionalized with ethylenediamine tetraacetic acid (APS-EDTA) adsorbent prepared and characterized by Fourier Transform Infrared Spectroscopy (FT-IR), Scanning Electron Microscopy (SEM) and X-ray Diffraction (XRD). Prepared APS-EDTA used for adsorptive studies of Cs(I), Co(II), Sr(II), Ni(II) and Cd(II) from contaminated water. The effect on adsorption of various parameters viz. contact time, initial concentration of metal ions and pH were also analyzed. The batch method has been employed using metal ions in solution from 1000-10000 ㎍/L, contact time 5-60 min., pH 4-10 and material quantities 50-200 mg at room temperature. The obtained adsorption data were used for drawing Freundlich and Langmuir isotherms model and both models were found suitable for explaining the metal ions adsorption on APS-EDTA. The adsorption data were followed pseudo second order reaction kinetics. The maximum adsorption capacity obtained 1.3037-1.4974 mg/g for above said metal ions. The results show that APS-EDTA have great potential to remove Cd(II), Co(II), Cs(I), Ni(II) and Sr(II) from aqueous solutions through chemisorption and physio-sorption.

Adsorption of THMs and THM Precursors on Activated Carbon Fibers (섬유상활성탄에 의한 THMs 및 THMs 전구물질의 흡착특성)

  • Han, Myung-Ho;Lee, Jin-Sik;Yoon, Yi-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.1
    • /
    • pp.121-130
    • /
    • 1996
  • Adsorption isotherms of three trihalomethanes(THMs: $CHCl_3$, $CHBrCl_2$ and $CHBr_2Cl$) and the other organics(p-chlorophenol and sucrose)on activated carbon fibers(ACFs) were measured. Adsorption capacities of the ACFs for these THMs were found to be comparable with or slightly larger than those of granular activated car bons(GACs) which have been widely used for trihalomethanes control in drinking water. Also, the breakthrough curve prediction was successfully carried out using a mathematical model on basis of the assumption that the adsorption equilibrium is instantaneously established when a THM solution contacts the ACF. In practice, THM removal from drinking water was investigated at water works using benchscale ACF adsorptJOn columns. The volume of water treated at a space velocity(SV) of about $100h^{-1}$ was approximately 40 l/g-ACF. The practical adsorption capacities of PCP and sucrose in column adsorption were in good agreement with those of theoretically calculated results using the batch adsorption measurments. And the saturation time model of these substrates in the columns was also agreed succesfully with practical measurments.

  • PDF

A Study of Adsorption Characteristics of Uranium ion Using Amidoximated PP-g-AN Fibrous ion-exchanger in Brine Water (AOPP-g-AN 섬유이온교환체를 이용한 간수로부터 우라늄 이온 흡착특성에 관한 연구)

  • 황택성;최재은;이재천
    • Polymer(Korea)
    • /
    • v.26 no.1
    • /
    • pp.121-127
    • /
    • 2002
  • We investigated uranium adsorption and adsorption process characteristics in brine water, changing column bed height packed with amidoximated polypropylene-g- acrylonitrile (AOPP-g-AN) fibrous ion-exchanger. Swelling ratios of AOPP-g-AN in fibrous ion-exchanger were 8.54g/g $H_2O_2$ and 8.87 g/g for $H_2O_2$ solvent respectively. Ion exchange capacity increased with degree of graft and showed the maximum, 3.99 meq/g at 100% degree of graft. In batch process, uranium adsorption had reached an initial equilibrium in 10 min with the adsorption rate of 9.5 mg/min. Finial adsorption capacity was 3.95 meq/g, and pH effect could not be observed. In continuous process, adsorption capacity depended on various packing ratios and showed the maximum, 3.92 meq/g at L/D=1. In L/D<2, breakthrough curve was shown two step by channeling flow and ununiform adsorption. Breakthrough time and adsorption capacity were 26 min and 3.63 meq/g, respectively, in brine water adsorption. When compared with actual brine water and model solution, there was no significant difference of adsorption characteristics.

Adsorption Characteristics of BTEX on Dust Collecting Electrode Coated with Activated Carbon (활성탄으로 코팅된 집진전극의 BTEX 흡착특성)

  • Nam, Sangchul;Kim, Hyun Jung;Kim, Kwang Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.773-779
    • /
    • 2013
  • This study was performed to provide the basic data for the function of BTEX removal for compact electrostatic precipitator which are applicable to indoor environment (or closed spaces). For this purpose, the adsorption equilibrium test was conducted for BTEX of activated carbon sheet (ACS) and activated carbon (AC), and the adsorption characteristics of AC and ACS were evaluated using the Langmuir constant which was obtained from the adsorption characteristics, adsorption capacity and regression calculation. The surface area and adsorption pore volume of ACS reduced by 70% and 86%, respectively, as compared to those of AC, and the adsorption capacities of BTEX also showed a similar level. Thus, it is considered that ACS applied electrostatic precipitator is able to remove dust and BTEX simultaneously.

Factors Affecting Protein Adsorption at the Air-Water Interface (계면에서의 단백질 흡착에 끼치는 영향인자)

  • Song, Kyung-Bin
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.521-525
    • /
    • 1993
  • To elucidate adsorption of proteins and examine the molecular behavior of protein molecules at interfaces, various proteins at the air-water interface were studied. The adsorption data of bovine serum albumin intermediates indicated that the conformational state of a protein played an important role in adsorption of proteins at interfaces. The adsorption behavior of succinylated beta-lactoglobulin indicated that the increase in the net negative charge of the protein significantly inflenced both the kinetics and thermodynamics of adsorption. The adsorption kinetics of beta-casein showed that the salt that induced break-down of water structure decreased the rate of adsorption.

  • PDF

Numerical Analysis of the Heat and Mass Transfer in a Fin Tube Type Adsorber (핀튜브형 흡착탑에서 열 및 물질전달 수치해석)

  • Kwon, Oh Kyung;Chung, Jae Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.457-463
    • /
    • 2013
  • Nowadays, adsorption chillers have been receiving considerable attention, as they are energy saving and environmentally benign systems. A fin tube type heat exchanger in which adsorption/desorption takes place is required with more compact size. The adsorption chiller is expected to have high energy efficiency in utilizing the waste heat exhausted from a process. The objectives of this paper are to scrutinize the effect of design parameters on the adsorption performance, especially the fin pitch of the fin tube, and to develop an optimal design fin tube heat exchanger in a silica gel/water adsorption chiller. From the numerical results, the fin pitch of 2.5 mm shows the highest adsorption rate, compared to other fin pitches, such as 5 mm, 7.5 mm and 10mm. Also, the adsorption rate is affected by the cooling water and hot water temperature.

Kinetics of Water Vapor Adsorption by Chitosan-based Nanocomposite Films

  • Seog, Eun-Ju;Zuo, Li;Lee, Jun-Ho;Rhim, Jong-Whan
    • Food Science and Biotechnology
    • /
    • v.17 no.2
    • /
    • pp.330-335
    • /
    • 2008
  • Water vapor adsorption kinetics of 3 different types of chitosan-based films, i.e., control chitosan, chitosan/montmorillionite (Na-MMT), and chitosan/silver-zeolite (Ag-Ion) nanocomposite films, were investigated at temperature range of $10-40^{\circ}C$. In all the films, water vapor is initially adsorbed rapidly and then it comes slowly to reach equilibrium condition. Reasonably good straight lines were obtained with plotting of 1/($m-m_0$) vs. l/t. It was found that water vapor adsorption kinetics of chitosan-based films was accurately described by a simple empirical model and the rate constant of the model followed temperature dependence according to Arrhenius equation. Arrhenius kinetic parameters ($E_a$ and $k_o$) for water vapor adsorption by chitosan-based films showed a kinetic compensation effect between the parameters with the isokinetic temperature of 315.52 K.

Effect of Packing Density of ion-Exchange on the Nickel Adsorption Column in Electroplating Rinse Water (이온교환 칼럼 충진비의 변화가 도금폐수 중 니켈이온 흡착에 미치는 영향)

  • 황택성;이진혁
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.551-558
    • /
    • 2002
  • It was observed that adsorption characteristics of sulfonated fabric ion-exchanger for separating nickel ion from electroplating rinse water. Swelling ratio was increased by increasing degree of sulfonation and polarity of solvent. Ion-exchange capacity was also increased by increasing degree of sulfonation and showed 3.38 meq/g at 16% sulfonated ion-exchanger. There was little effects of pH. Adsorption equilibrium was attained within 10 min, and adsorption rate was 7.5 mg/min. Adsorption capacity was not changed after 7 cycles of regeneration process. Regeneration adsorption capacity was slightly decreased to 2.01 meq/g. It confirmed that durability of sulfonated fabric ion-exchanger was suitable for adsorption process. Adsorption equilibrium time was linearly increased by increasing L/D and adsorption capacity showed the ion exchange capacity within the range of 2.71 ∼ 3.01 meq/g in continuous process. Design of adsorption column could be possible for L/D<2. Under constant L/D condition, there is no little pH effect when rinse water is acidic solution, and operation condition of adsorption process was optimized under pH 5.

Evaluation of Adsorption Characteristics of Radioactive Iodine (I-131) for Various Materials of Granular Activated Carbon (GAC) (입상활성탄 재질별 방사성 핵종(I-131) 흡착 특성 평가)

  • Park, Hong-Ki;Son, Hee-Jong;Yeom, Hoon-Sik;Kim, Young-Jin;Choi, Jin-Taek;Ryu, Dong-Choon
    • Journal of Environmental Science International
    • /
    • v.24 no.9
    • /
    • pp.1123-1129
    • /
    • 2015
  • This research was performed by means of several different virgin granular activated carbons (GAC) made of each coal, coconut and wood, and the GACs were investigated for an adsorption performance of iodine-131 in a continuous adsorption column. Breakthrough behavior was investigated that the breakthrough points of the virgin two coals-, coconut- and wood-based GACs were observed as bed volume (BV) 7080, BV 5640, BV 5064 and BV 3192, respectively. The experimental results of adsorption capacity (X/M) for iodine-127 showed that two coal- based GACs were highest (208.6 and $139.1{\mu}g/g$), the coconut-based GAC was intermediate ($86.5{\mu}g/g$) and the wood-based GAC was lowest ($54.5{\mu}g/g$). The X/M of the coal-based GACs was 2~4 times higher than the X/M of the coconut-based and wood-based GACs.

Adsorption Characteristics of Al (III), Ni (II), Sm (III) Ions on Resin with Styrene Hazardous Material in Reinforcement Water Fire Extinguishing Agent

  • Kim, Joon-Tae
    • Journal of Integrative Natural Science
    • /
    • v.6 no.3
    • /
    • pp.151-157
    • /
    • 2013
  • The ion exchange resins were synthesized from 1-aza-18-crown-6 macrocyclic ligand attached to styrene (2th petroleum in 4th class hazardous material) divinylbenzene (DVB) copolymer with crosslinks of 1%, 6%, and 15% by substitution reaction. These synthetic resins were confirmed by chlorine content, elementary analysis, surface area, and IR-spectrum. The object of this study was to seperate the metal ion absorbed in reinforcement water fire extinguishing agent. As the results of the effects of pH, equilibrium arrival time, and crosslink of synthetic resin on metal ion adsorption for resin adsorbent, the metal ions were showed high adsorption at pH 3 or over and adsorption equilibrium of metal ions was about 2 hours. In addition, adsorption selectivity for the resin in water was the order of Al (III) > Ni (II) > Sm (III) ions, adsorbability of the metal ions was in the crosslinks order of 1%, 6%, and 15%.