• 제목/요약/키워드: Temperature monitoring system

검색결과 1,135건 처리시간 0.034초

광학특성을 가진 수질변수를 활용한 하구 담수호 내 TOC 농도 추정 (Estimating TOC Concentrations Using an Optically-Active Water Quality Factors in Estuarine Reservoirs)

  • 김진욱;장원진;신재기;강의태;김진휘;박용은;김성준
    • 한국물환경학회지
    • /
    • 제37권6호
    • /
    • pp.531-538
    • /
    • 2021
  • In this study, the TOC in six estuarine reservoirs in the West Sea (Ganwol, Namyang, Daeho, Bunam, Sapkyo, and Asan) was estimated using optically-active water quality factors by the water environment monitoring network. First, specification data and land use maps of each estuarine reservoir were collected. Subsequently, water quality data from 2013 to 2020 were collected. The data comprised of 11 parameters: pH, dissolved oxygen, BOD, COD, suspended solids (SS), total nitrogen, total phosphorus, water temperature, electrical conductivity, total coliforms, and chlorophyll-a (Chl-a). The TOC in the estuarine reservoirs was 4.9~7.0 mg/L, with the highest TOC of 7.0 mg/L observed at the Namyang reservoir, which has a low shape coefficient and high drainage density. The correlation of TOC with water quality factors was also analyzed, and the correlation coefficients of Chl-a and SS were 0.28 and 0.19, respectively, while the correlation coefficients of these factors in the Namyang reservoir were 0.42 and 0.27, respectively. To improve the estimation of TOC using Chl-a and SS, the TOC was averaged in 5 mg/L units, and Chl-a and SS were averaged. Correlation analysis was then performed and the R2 of Chl-a-TOC was 0.73. The R2 of SS-TOC was 0.73 with a non-linear relationship. TOC had a significant non-linear relationship with Chl-a and SS. However, the relationship should be assessed in terms of the spatial and temporal variations to construct a reliable remote sensing system.

사물인터넷 프로토콜 기반의 미세먼지 측정 플랫폼 설계와 기능해석 (Design and Function Analysis of Dust Measurement Platform based on IoT protocol)

  • 조용찬;김정호
    • Journal of Platform Technology
    • /
    • 제9권4호
    • /
    • pp.79-89
    • /
    • 2021
  • 본 논문은 사물인터넷 국제 표준 oneM2M을 활용하여 미세먼지(PM10)와 초미세먼지(PM2.5) 측정 플랫폼을 이동식과 고정식으로 설계하였다. 미세먼지 측정 플랫폼은 미세먼지 측정 디바이스, 에이전트, oneM2M 플랫폼, oneM2M IPE, 모니터링 시스템으로 구성하고 설계하였다. 이동식과 고정식의 주요 차이는 이동식은 LTE 연결을 기반으로 사각지대 없이 디바이스와 서비스간에 상호연결을 위해 MQTT 프로토콜을 사용하였고, 고정식은 저전력과 넓은 통신범위를 가진 LoRaWAN 프로토콜을 사용하였다. 미세먼지뿐만 아니라 일상생활과 연관된 온도, 습도, 대기압, 휘발성 유기화합물(VOC), 일산화탄소(CO), 아황산가스(SO2), 이산화질소(NO2), 소음 데이터를 수집하였다. 수집된 센서 값들은 에이전트와 oneM2M IPE를 통해 oneM2M이 제공해주는 공통 API를 활용하여 관리하였고, AE, container 등 4가지 리소스 타입으로 설계하였다. 미세먼지 측정 플랫폼 설계를 통해 동작성, 유연성, 편의성, 안전성, 개방성, 확장성의 6가지 기능을 해석하였다.

스마트팜 센서 처리용 MCU 모듈 설계 (MCU Module Design for Smart Farm Sensor Processing)

  • 김관형
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.285-286
    • /
    • 2021
  • 최근 IoT(Internet of Things) 기술의 발전으로 스마트화 기술이 농업, 축산업, 수산업 분야로 확장되어 스마트화가 진행되고 있다. 이러한 스마트화 기술은 현장의 데이터를 어떻게 계측하여 관리 시스템으로 전송하는가가 무엇보다 중요하다. 현재 스마트팜 및 기타 축사 및 양식장 구축에 활용되는 센서는 온도, 습도, CO 가스, CO2, 수소(Hydrogen), O2 등 다양한 센서를 통하여 스마트팜 및 기타 환격을 계측하고 모니터링하고 있다. 이러한 센서들과 스마트팜을 제어하고 관리하는 HMI(Human Machine Interface) 모듈과의 통신방식은 아직 까지는 RS-485 기반의 모드버스(modbus-RTU) 방식을 주로 활용하고 있다. 본 논문에서는 스마트팜 구축에 필요한 센서 데이터를 HMI 모듈에서 관리할 수 있도록 RS-485 기반의 모드버스 방식을 통하여 데이터를 관리할 수 있도록 다양한 센서 모듈을 연결할 수 있도록 HMI용 MCU 모듈을 설계하고자 한다.

  • PDF

고준위방사성폐기물 처분장 모니터링용 피에조센서의 온도 스트레스에 관한 가속수명시험 설계 (Design of accelerated life test on temperature stress of piezoelectric sensor for monitoring high-level nuclear waste repository)

  • 황현중;박창희;홍창호;김진섭;조계춘
    • 한국터널지하공간학회 논문집
    • /
    • 제24권6호
    • /
    • pp.451-464
    • /
    • 2022
  • 고준위방사성폐기물 처분장은 심지층 처분시스템으로 사용후핵연료를 취급하는 특성상 고온, 방사선 및 지하수 등의 복합적인 환경조건에 노출되어 있다. 지속적인 노출에 의해 시간이 지남에 따라 구조물의 균열 및 열화가 발생할 수 있다. 한편 고준위방사성폐기물 처분장은 초장기 기대수명이 요구되며 이에 따른 장기적인 구조물 건전성 모니터링이 필수적이다. 구조물 건전성 모니터링에는 가속도계, 토압계, 변위계 등 다양한 센서들이 활용될 수 있으며, 이 중 일반적으로 피에조센서가 사용된다. 따라서 피에조센서의 내구성 평가를 바탕으로 고내구성 센서를 개발할 필요가 있다. 본 연구에서는 피에조센서의 내구성 평가 및 수명예측을 위한 가속수명시험을 설계하였다. 문헌연구를 바탕으로 단일 스트레스 인자에 대한 가속 스트레스 수준 수 및 각 수준 별 시료 수를 선정하였다. 또한 고준위방사성폐기물 처분장 환경조건에서 발생할 수 있는 피에조센서의 고장모드 및 고장메커니즘을 분석하였다. 온도 스트레스 인자에 대한 최대 가혹조건 탐색 실험을 두 가지 방법으로 제안하였으며 피에조센서의 신뢰도 높은 동작한계를 도출하였다. 이를 이용하여 가속수명시험의 합리적인 가속 스트레스 수준을 설정하였다. 본 연구에서 제시된 최대 가혹조건 탐색 실험방법은 경제적이며 실용적인 아이디어를 담고 있으며, 추후 피에조센서의 가속수명시험 설계에 널리 활용될 수 있을 것으로 판단된다.

공주 청량사지 오층석탑 및 칠층석탑의 정밀 계측모니터링과 미세거동 해석 (Interpretation of Microscale Behaviors and Precision Measurement Monitoring for the Five-story and Seven-story Stone Pagodas from Cheongnyangsaji Temple Site in Gongju, Korea)

  • 이정은;박석태;이찬희
    • 헤리티지:역사와 과학
    • /
    • 제56권4호
    • /
    • pp.132-158
    • /
    • 2023
  • 공주 청량사지 오층 및 칠층석탑은 계룡산 삼불봉 아래에 있으며, 고려 중기에 창건한 것으로 알려진 탑으로 한 시대에 두 유형의 백제계 석탑이 공존하는 쌍탑으로서 역사적 및 학술적 가치를 인정받고 있다. 두 탑은 1944년 도굴로 칠층석탑이 전도되고 그 영향으로 오층석탑에 기울어짐이 발생하였다. 1961년에 석탑을 복원하였으나 구조적 불안정성은 지속적으로 제기되었다. 따라서 이 연구에서는 2021년 5월부터 2022년 3월까지 계측자료를 축적하고 계절적 특성을 검토하여, 동일 기간의 기온변화와 강수량에 따른 석탑의 미세거동을 해석하였다. 이 결과, 모든 계측기에서 일간 기온변화에 따라 미세한 열탄성거동을 반복하였으며, 경사와 변위 모두 미세거동이 나타났다. 경사계에서는 기온변화에 따라 석재의 표면과 내부에 포함된 수분이 팽축을 반복하며 미세한 움직임을 보였고, 변위계에서도 시계열에 따라 기온이 상승하면서 모두 이격거리가 감소하였다. 특히 오층석탑 상부는 북서쪽으로 최대 3.89° 거동하였으며, 칠층석탑은 북동쪽으로 최대 0.078° 기울었다. 최대 변위는 오층석탑과 칠층석탑에서 각각 0.127 및 0.149mm로 기록되었다. 이 값들은 계측 종료시점에 원래 상태로 회귀하는 경향은 있으나 완전히 회복하지 못하여 면밀한 감시가 필요한 상태를 지시하였다. 이 연구를 통해 획득한 결과는 두 석탑의 안정적 보존을 위한 기초자료로 활용될 수 있다. 이를 기반으로 다양한 환경요소를 고려한 거동특성이 분석되어야 하며, 계측시스템의 유지관리를 통한 예방보존이 지속되어야 할 것이다.

충남지역 다중이용시설의 환경수계에서 분리한 레지오넬라균의 특성 분석 (Characterization of Legionella Isolated from the Water System at Public Facilities in Chungcheongnam-do Province)

  • 천영희;이현아;남해성;최지혜;이다연;고영은;박종진;이미영;박준혁
    • 한국환경보건학회지
    • /
    • 제47권5호
    • /
    • pp.472-478
    • /
    • 2021
  • Background: The Legionella case detection and notification rate have increased in public artificial water environments where people visit, including large buildings, public baths, and hospitals. Objectives: In this study, the distribution of Legionella and its epidemiologic characteristics were analyzed in the water systems of public facilities in Chungcheongnam-do Province in South Korea. Methods: Culture and PCR analysis were performed on 2,991 environmental water system samples collected from 2017 to 2019, and associations with year, facilities, seasons, and temperature of water system were statistically analyzed by using R-Studio for Windows. Descriptive data was compared using chi-square tests and independent t-tests. Results: The detection rate of Legionella increased from 3.1% in 2017 to 10.3% in 2019, appearing most frequently in the order of public baths, large-scale buildings, hospitals, and apartments. It was detected mainly in summer from June to August, over 1.0×103 CFU/L on average in 133 cases (66.5%). Lots of germs were detected in bathtub water, cooling tower water, and warm water (p<0.001), and it was detected at higher rates in the cities where multipurpose facilities were concentrated than in rural areas (p=0.018). Conclusions: This study suggests that continuous monitoring and control are required for Legionella in the water system environment of high risk facilities. Moreover, these results will be helpful to prepare efficient management plans to prevent the Legionellosis that occurs in Chungcheongnam-do Province.

스웨덴 고준위방사성폐기물 심층처분시설의 설계 사례 분석 (Case Study of Deep Geological Disposal Facility Design for High-level Radioactive Waste)

  • 임주휘;정재훈;전석원;송기일;신영진
    • 터널과지하공간
    • /
    • 제33권5호
    • /
    • pp.312-338
    • /
    • 2023
  • 고준위방사성폐기물 심층처분시설은 고온의 사용후핵연료에서 핵종 누출을 막기 위해 열적, 역학적, 수리적 안전성이 장기적으로 확보되도록 일반적인 지하터널과는 다른 특별한 설계가 필요하다. 스웨덴 SKB는 고준위방사성폐기물 처분시설의 설계 기준을 수립하고 포쉬마크 지역에 대해 실제 설계를 수행하였다. 그리고 지반 불확실성에 대응하기 위해 모니터링과 그에 따른 설계 변경이 가능한 관찰 기법과 단계별 개발법을 제안하였다. SKB는 지반 유형과 지반 거동을 분류하고 포쉬마크 지역에 존재하는 지반유형과 거동의 조합에 적절한 지보 유형을 대응시키는 독자적인 지보 시스템을 개발하였고 기존 지보 시스템과 비교를 통해 안전성을 확인하였다. POSIVA는 SKB와 유사한 방식으로 온칼로 지역에 대해 지보시스템을 개발하였으나 포쉬마크와는 상이한 지반 특성을 반영하였다. 이를 참고하여, 국내 고준위방사성폐기물 심층처분시설 건설을 위한 설계가 이루어질 수 있을 것이며 국내 특성에 맞는 지보 시스템 또한 수립될 수 있을 것이다.

절화장미의 수분관계와 노화에 대한 용기내 수온과 엽수의 효과 (Effect of Vase Water Temperature and Leaf Number on Water Relations and Senescence of Cut Roses)

  • 인병천;장명갑;변혜진;손기철
    • 원예과학기술지
    • /
    • 제28권4호
    • /
    • pp.609-617
    • /
    • 2010
  • 절화 장미의 수분관계와 노화반응에 대한 용기내 수온과 엽수의 효과를 조사하였다. 신선한 상태로 수확된 'Red Sandra' 장미의 줄기는 상위엽 2매 또는 4매와 함께 길이 50cm로 정리되었다. 절화는 상온증류수($23^{\circ}C$; AT-DW), 저온증류수 ($7^{\circ}C$; LT-DW), 또는 저온보존용액(LT-PW)이 포함된 용기에 침지된 상태로 환경제어실에서 유지되었다. 처리간의 효과는 절화수명, 화경, 생체중 및 수분흡수량의 변화에 의하여 평가되었다. 수분관계에 있어서 차이는 $CO_2$동화율, 기공전도, 그리고 줄기수분유속(SFR)을 측정함으로써 판단되었다. 수분흡수율은 LT-DW 장미에서 현저하게 증가되었고, LT-PW 장미에서 감소되었다. LT-PW 장미는 실험기간 동안 낮은 용액흡수량을 보였음에도 불구하고, 높은 생체중, 가장 긴 정의 수분균형기간, 그리고 가장 큰 화경을 나타냈다. 2매엽의 장미는 높은 생체중과 향상된 수분 균형을 유지한 결과로 절화수명이 연장되었다. $CO_2$동화율과 기공전도도는 LT-PW에 유지함으로써 현저하게 감소되었고, 엽수의 감소에 의하여 증가되었다. AT-DW장미의 경우, 줄기상부에 비하여 줄기하부의 SFR이 낮았으나, LT-DW 장미는 줄기하부의 SFR이 훨씬 컸다. 이것은 저온수가 줄기내의 수분전도율을 향상시킨다는 것을 나타낸다. 반면, LT-PW 장미는 실험기간 동안 안정된 SFR을 유지하였고, 줄기상부와 줄기하부에서 유사한 SFR 패턴을 나타냈다. 결과적으로 LT-PW와 LT-DW장미는 AT-DW 장미에 비하여 절화수명이 각각 8일과 4일 이상 연장되었다.

다중 반사파 중첩 자료의 상호상관을 이용한 엔지니어링 플라스틱 코어의 초음파속도 측정 (Ultrasonic Velocity Measurements of Engineering Plastic Cores by Pulse-echo-overlap Method Using Cross-correlation)

  • 이상규;이태종;김형찬
    • 지구물리와물리탐사
    • /
    • 제16권3호
    • /
    • pp.171-179
    • /
    • 2013
  • 여러 가지 초음파 속도 측정법 중 비교적 정확하고 다양한 목적에 활용될 수 있다고 알려진 반사파 중첩법(pulseecho-overlap method)에 의해 초음파의 전파시간을 자동으로 측정할 수 있는 시스템을 구축하고, 엔지니어링 플라스틱 시험편에 대한 초음파 속도를 초동발췌법(first arrival picking method)과 비교하였다. 다섯 가지 종류의 엔지니어링 플라스틱 코어에 대해 반사파 중첩법과 초동발췌법에 의해 초음파 속도를 측정한 결과, 반사파 중첩법은 초동발췌법보다 최소 4배로 긴 다중반사파 자료가 필요하므로 매질의 감쇠특성에 의해 측정가능한 시험편의 길이에 제약이 있다. 또한 측정되는 속도는 초동발췌법에 의한 속도보다 낮게 측정되는 경향을 보였으며, 수신된 파형을 분석한 결과, 이는 전파거리가 길어짐에 따른 매질의 감쇠 및 분산특성에 의한 영향으로 해석되었다. 상호상관을 이용하여 제1반사파가 제2반사파 및 제3반사파와 가장 잘 중첩되는 시간을 실시간으로 자동으로 발췌하도록 프로그램하여 실험자에 의한 측정 편차가 개입될 가능성을 배제함으로써 반복성과 재현성을 높였다. 또한, 실험의 조건이 변하지 않는 경우는 중합수를 늘림으로서 무작위 잡음에 의한 측정오차를 줄일 수 있으며, 실험 조건이 변하는 경우는 속도변화 모니터링에도 활용이 가능하다.

열전냉각방식의 범용 CCD 카메라 시스템 개발 II. 소프트웨어 (A DESIGN AND DEVELOPMENT OF MULTI-PURPOSE CCD CAMERA SYSTEM WITH THERMOELECTRIC COOLING II. SOFTWARE)

  • 오세헌;강용우;변용익
    • Journal of Astronomy and Space Sciences
    • /
    • 제24권4호
    • /
    • pp.367-378
    • /
    • 2007
  • 천체관측용 고효율 CCD 카메라 시스템과 제어소프트웨어의 독자 개발의 시도로, 우리는 범용 CCD 카메라 시스템을 제작하고, 이를 Linux 운영체제 기반의 PC에서 병렬포트를 이용하여 제어하는 소프트웨어를 개발 완료하였다. 이 소프트웨어는 우리가 개발한 카메라에 장착될 수 있는 KAF-0401E($768\;{\times}\;512$), KAF-1602E($1536\;{\times}\;1024$), KAF-3200E($2184\;{\times}\;1472$) 등 세 가지 모델의 CCD 칩에 대해 모두 사용될 수 있다. 제작된 CCD 카메라를 효율적으로 제어하기 위하여, 개발된 소프트웨어는 CCD를 제어하는 부분과 온도와 셔터를 제어하는 부분의 두가지 구성으로 되어 있다. 이 중, 온도와 셔터의 제어는 CCD 동작과 무관하게 작동될 수 있도록 독립적인 프로세스로 작동되며, 관측 시에는 Linux의 다중 프로세스를 제어하는 소프트웨어를 통하여 통합 제어된다. 개발된 소프트웨어는 CCD 카메라를 수동 혹은 자동으로 구동할 수 있으며, 전천을 탐사하는 자동관측 시스템의 기상 모니터나 일반 천체관측 등에 범용으로 사용할 수 있을 것이다. 시험 결과, KAF-0401E, KAF-1602E, KAF-3200E, 각각의 CCD에 대하여 약 15초, 64초, 134초 정도의 영상 읽기 시간이 소요되었으며, 이는 병렬포트 전송속도의 한계로 인한 것이다. 따라서 보다 넓은 수광영역을 가진 CCD를 사용하기 위해서는 입출력 속도를 높일 필요가 있으며, 이를 위하여 USB 포트를 이용한 제어를 고려하고 있다.