• Title/Summary/Keyword: Standard pattern

Search Result 1,490, Processing Time 0.04 seconds

Preliminary Research for Developing a Pattern Identification Tool for Idiopathic Pulmonary Fibrosis (특발성 폐섬유화증 변증 도구 개발을 위한 기초연구)

  • Hong, Sung-eun;Park, Ji-won;Shin, Jeong-won;Kil, Jung-eun;Kim, Kwan-il;Bu, Yung-min;Jung, Hee-jae;Lee, Beom-joon
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.327-343
    • /
    • 2022
  • Objective: The purpose of this study was to develop a standard tool for identifying idiopathic pulmonary fibrosis patterns. Methods: Textbooks, published literature, and references with comments on patterns were reviewed. Using the Delphi method, we determined pattern identification based on the advice of a committee consisting of 11 Korean respiratory internal medicine professors. Results: Four pattern identifications were selected by the Delphi method: qi difficiency (氣虛), yin difficiency (陰虛), phlegm dampness (痰飮), blood stasis (瘀血). The tool was developed in a question-and-answer format containing 38 questions. Conclusions: An IPF pattern identification tool that can analyze IPF patterns for standardized diagnostics was developed with the consent of experts. Further research is needed on its reliability.

Quantitative X-ray Diffraction Analysis of Synthetic Mineral Mixtures Including Amorphous Silica using the PONKCS Method (PONKCS 방법을 이용한 비정질 실리카 함유 인공광물혼합시료의 정량 X-선회절 분석)

  • Chon, Chul-Min;Lee, Sujeong;Lee, Sung Woo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.27-34
    • /
    • 2013
  • X-ray powder diffraction is one of the most powerful techniques for qualitative and quantitative analysis of crystalline compounds. Thus, there exist a number of different methods for quantifying mineral mixtures using X-ray diffraction pattern. We present here the use of Rietveld and PONKCS (partial or no known crystal structure) methods for quantification of amorphous and crystallized mineral phases in synthetic mixtures of standard minerals (amorphous silica, quartz, mullite and corundum). Pawley phase model of amorphous silica was successfully built from the pattern of 100 wt% amorphous silica and internal standard-spiked samples by PONKCS approach. The average of absolute bias for quantities of amorphous silica was 1.85 wt%. The larger bias observed for lower quantities of amorphous silica is probably explained by low intensities of diffraction pattern. Averages of absolute bias for minerals were 0.53 wt% for quartz, 0.87 wt% for mullite and 0.57 wt% for corundum, respectively. The PONKCS approach achieved improved quantitative results compared with classical Rietveld method by using an internal standard.

Analysis of Non-Point Source Pollution Discharge Characteristics in Leisure Facilities Areas for Pattern Classification (패턴분류를 위한 위락시설지역의 비점오염원 유출특성분석)

  • Kim, Yong-Gu;Jin, Young-Hoon;Park, Sung-Chun;Kim, Jung-Min
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.12
    • /
    • pp.1029-1038
    • /
    • 2010
  • In meteorology Korea has 2/3 of rain of annual total rainfall at the month of Jun through Sept and it has possibility to have serious flood damage because geographically it is composed of mountainous area with steep slope which account for 70% of its country. Also, the increase of impervious layer due to industrialization and urbanization causes direct runoff, which deteriorates contamination of rivers by moving the contaminated material on the surface at the beginning of rain. In particular, the area of leisure facilities needs the management of water quality absolutely because dense population requires space of park function and place to relax and increases moving capability of non-point pollution source. For disposition of rainfall & runoff, the standard of initial rainfall, which is to be used for the computation of disposition volume, is significant factors for the runoff study of non-point pollution source, Until now, a great deal of study has been done by many researchers. However, it is the current reality that the characteristics of runoff varies according to land protection comprising river basin and the standard of initial rainfall by each researcher is not clearly defined yet. Therefore, in this research, it is suggested that, with the introduction of SOM (Self-Organizing Map), the standard of initial rainfall be determined after analyzing each sectional data by executing pattern classification about runoff and water quality data measured at the test river basin for this research.

Study on Performance Evaluation of Dental X-ray Equipment (치과 방사선 발생기의 성능평가에 관한 연구)

  • Jung, Jae-Eun;Jung, Jae-Ho;Kang, Hee-Doo;Lee, Jong-Woong;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

Study on Electrical Resistivity Pattern of Soil Moisture Content with Model Experiments (토양의 함수율에 따른 전기비저항 반응 모형 실험 연구)

  • Ji, Yoonsoo;Oh, Seokhoon;Lee, Heui Soon
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.2
    • /
    • pp.79-90
    • /
    • 2013
  • Geophysical investigation in non-destructive testing is economically less expensive than boring testing and providing geotechnical information over wide-area. But, it provides only limited geotechnical information, which is hardly used to the design. Accordingly, we performed electrical resistivity experiments on large scale of soil model to analyze the correlation between electrical resistivity response and soil water contents. The soils used in the experiments were the Jumunjin standard sand and weathered granite soil. Each soil particle size distribution and coefficient of uniformity of experimental material obtained in the experiments were maintained in a state of the homogeneous. The specifications of the model used in this study is $160{\times}100{\times}50$(cm) of acrylic, and each soil was maintained at the height 30 cm. The water content were measured using the 5TE sensors (water contents sensors) which is installed 7 ~ 8 cm apart vertically by plugging to floor. The results of the resistivity behavior pattern for Jumunjin standard sand was found to be sensitive to the water content, while the weathered granite soil was showing lower resistivity over the time, and there was no significant change in behavior pattern observed. So, it results that the Jumunjin standard sand's particle current conduction was better than the weathered granite soil's particle through contact with the distilled water. This lab test was also compared with the result of a test bed site composed of similar weathered soil. It was confirmed that these experiments were underlying research of non-destructive investigation techniques to improve the accuracy to estimate the geotechnical parameter.

A Study on Floor Impact Sound due to Resilient Materials in Apartment Buildings (공동주택의 소음 저감재 설치로 인한 바닥 충격음에 관한 연구)

  • 김병길;김수련;곽규성;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.5-10
    • /
    • 2004
  • Apartment Buildings have particularity to cluster together, especially, floor is close to resident, it is subject to dissatisfaction about impact noise between up and down floors. However, we require standard for counterplan to reduce the impact noise of floor. In point of fact, it difficult to objective evaluate for performance sound insulation that not physical sound volume but orignal form, means and effect of sound caused to complex noise in apartment house. Unique type of dwelling and structure pattern cause to noise of floor impact which is established by law for standard regulation. It is object to analysis and compare the result of performance sound insulation of upper floor impact and sample construct the subject resilient material of sound insulator

  • PDF

Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea (부산 해안지역의 고농도 오존 발생 특성에 관한 연구)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

A Study on the Characteristics of Surface Ozone Concentration at Dongsamdong, Pusan (부산 동삼동 지역의 지표오존농도 특성 연구)

  • Jeon, Byung Il
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.2
    • /
    • pp.21-29
    • /
    • 1999
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone and meteorological data of 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was highest in Spring(35.4ppb) and lowest in Winter(22.2ppb). Relative standard deviation indicating clearness of observation site was 0.42 that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong showed maximum at 15~16LST and minimum 07~08LST that typical pattern of ozone concentration. In ozone episode period(May 18~23, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface.

  • PDF

Development of Portable Electronic Tongue using Fuzzy clustering algorithm (Fuzzy Clustering 알고리즘을 이용한 휴대용 전자 혀 개발)

  • Kim, Joeng-Do;Ham, Yu-Kyung;Jung, Woo-Suk;Jung, Young-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.602-604
    • /
    • 2004
  • A portable electronic tongue(E-Tongue) system using an array of ion-selective electrode(ISE) and personal digital assistants(PDA) for recognizing and analyzing food and drink have been designed. By the employment of PDA, the complex algorithm such as fuzzy c-means algorithm(FCMA) could be used in E-Tongue, FCMA could iteratively solve the cluster centers of pre-determined standard patterns. And the membership between the standard patterns and unknown pattern could be analyzed easily by the present E-Tongue combined with PDA.

  • PDF

Detection and Classification of Bearing Flaking Defects by Using Kullback Discrimination Information (KDI)

  • Kim, Tae-Gu;Takabumi Fukuda;Hisaji Shimizu
    • International Journal of Safety
    • /
    • v.1 no.1
    • /
    • pp.28-35
    • /
    • 2002
  • Kullback Discrimination Information (KDI) is one of the pattern recognition methods. KDI defined as a measure of the mutual dissimilarity computed between two time series was studied for detection and classification of bearing flaking on outer-race and inner-races. To model the damages, the bearings in normal condition, outer-race flaking condition and inner-races flaking condition were provided. The vibration sensor was attached by the bearing housing. This produced the total 25 pieces of data each condition, and we chose the standard data and measure of distance between standard and tested data. It is difficult to detect the flaking because similar pulses come out when balls pass the defection point. The detection and classification method for inner and outer races are defected by KDI and nearest neighbor classification rule is proposed and its high performance is also shown.