Study on the Performance of the Flat-Plate Solar Collectors (평면식 태양열 집열기의 성능에 관한 연구)

  • 장규섭;김만수
    • Journal of Biosystems Engineering
    • /
    • v.2 no.2
    • /
    • pp.37-45
    • /
    • 1977
  • Solar energy is a potential source of power that offers much promise being used for low-temperature applications like drying farm crops, space heating, and water heating for domestic uses. Already much of it are being used for those purpose in foreign countries. However, very little research has been done to determine the possibility of using the solar energy in Korea. This study was conducted to develop the general prediction equation of the total radiation on a horizontal surface in Daejeon area based on 5 years 91972, Jun.1-1976. Dec.31) meteorological data (bright sunshine hours, average total horizontal radiation), and to obtain experimentally the thermal efficiency of solar air and water collectors, which will be used as a basic data of designing flat-plate solar collector system.In addition to the thermal efficiency of the collectorsthe relationship among those factors affecting it such as weather condition, orientation factor, and tilted angle of collector was analyzed. The results of this study were as follows. 1. The general predicted equation of the total radiation on a horizontal surface in Daejeon area based on bright sunshine hours was developed as $H_{av} =(1.546\frac{n}{N}-0.582)H_o$. Predicting the total radiation on a horizontal surface by the above equation was thought to be possible because to values of 0.882 was smaller than any t values at above 0.05 level on the basis of two tailed test of the difference between the calculated and the recorded values. 2.It was observed that optimum tilt angle of the collector in the summer and the autumn drying season was 13 degrees and 51 degrees respectively, these values could be obtained by adding or substracting approximately 25 degrees from the latitude of this area $(36.3^{\circ}N)$ .The relationship between orientation factor and declination of sun at suitable tilt angle of 33 degrees $(s=0.9\O)$ was shown at Fig.4. 3.The thermal efficiency of solar wdter collector was shown 13.4-51. 6% on Aug. 15 (the minimum radiation recorded) and 43.8 ~537% Aug.20 (the maximum radiation recorded), and 13.8~ 46.6 and 44.3~ 49.7 were shown on each corresponding day. 4.The thermal efficiency of the collectors according to the weather condition was shown a big difference of about 10% between the day of the maximum radiation recorded and the minimum, but the differen of efficiency between the air and the water collector was at most 2 ~ 3%. 5. Even if the efficiency of the solar water collector was a little higher than the solar air collector, for drying farm products, the solar air collector was thought to be more effective because the air heated by collector could be directly used for drying them.

  • PDF

Floor Heating Characteristics of Latent Heat Storage-Bioceramic Ondol(II) - Focused on Theoretical Analysis - (잠열 축열-바이오 세라믹 온돌의 난방 특성(II) - 이론적 분석을 중심으로 -)

  • Song, Hyun-Kap;Ryou, Young-Sun
    • Solar Energy
    • /
    • v.15 no.2
    • /
    • pp.13-24
    • /
    • 1995
  • Korean traditional Ondol with the sensible heat storage medium has been for a long time used as residential heating system, in these days the concrete Ondol without the heat storage medium was realized as the heating system in the private houses and the apartments. This floor heating system is good for our health. But the concrete Ondol is not desirable for the energy saving and for the maintenance of comfortable room temperature because the heat storage medium is not employed in the concrete Ondol. And as the hot water circulating pipes are buried under the concrete floor, the concrete Ondol system has some kind of problems to be improved. Therefore the new type of Ondol system was developed in this study. And the new Ondol was consisted of latent heat storage material as heat storage medium with a great heat capacity and bioceramics as medium to maintain comfortable room temperature. In this study, the heat transfer characteristics of latent heat storage-bioceramic Ondol was analyzed theoretically.

  • PDF

A Study on the Energy Efficiency Improvement according to Operation Condition of Solar Thermal System in Office Buildings (사무소 건물의 태양열 시스템 운영조건 변화에 따른 에너지 효율 향상에 관한)

  • Jung, Young-Ju;Kim, Seok-Hyun;Lee, Yong-Ho;Hwang, Jung-Ha;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.109-115
    • /
    • 2014
  • The supply rate of renewable energy has been increasing under the influence of an energy scarcity. Government has supported the use of renewable energy by government subsidies. The operation of renewable may not been operating appropriately, although increasing the use of renewable energy. We found out some problems of the operation of renewable energy and offered some improvements. This research proposes the efficient operation method for the solar thermal system, and proposed operation method was compared and evaluated with existing operation strategy after selecting one building installed solar thermal system. Recently, the interest to renewable energy has increased because of the environmental issues and energy crisis. However the utilization of the renewable energy system is low because of the use of renewable energy system and existing renewable energy system independently, although supply rate of renewable system is increasing. Especially, in the case of solar thermal system heating load is not responsible for the load of hot water supply in many cases. Therefore, suggesting efficient operation plans and evaluations of the energy consumption and efficiency of a solar thermal system is needed.

A Study on the Performance of Ground Source Heat Pump System (지중열원 열펌프시스템의 성능해석)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.69-76
    • /
    • 2005
  • The performance of water-to-water heat pump system coupled with the ground source vertical heat exchanger is presented in this paper. The CAP program of Florida Heat Pump Co. is used to predict the heat pump performances while the EED program calculates the borehole fluid temperature. It is shown that COPH increases with decreasing the temperature of output water for the operation of heating mode and COPR increases with increasing temperature of output water for the operation of cooling mode. The value of specific heat extraction rate must be moderate to insure the reasonable installation cost of borehole system. With $1^{\circ}C$decrease of $T_{wo}$ the average COPH increase is estimated as about $0.06/^{\circ}C$(for $T_{wo}\;=\;45{\sim}60^{\circ}C$ range) while with $1^{\circ}C$ increase of $T_{wo}$ the estimation of COPR increase is about $0.13/^{\circ}C$(for $T_{wo}\;= \;5{\sim}11^{\circ}C$ range) at the specific heat extraction rate of 30W/m.

Evaluation of Residential Performance in Commercialization of Flexible Unit Infra Free Residential for Disaster (재난 시 대응을 위한 Flexible-Unit형 인프라 프리(임시)주거의 성능평가)

  • Park, Beungyong;Cho, Jinkyun;Jeong, Yongdae;Lee, Wonhak
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.6
    • /
    • pp.37-49
    • /
    • 2018
  • In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The design trend implemented the energy insulation, solar PV panels, energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated the physical performance, insulation, airtightness. The second step, we was evaluated energy performance building to design heating and cooling system to combined PV system. As a results, the insulation performance wall was $0.18W/(m^2{\cdot}K)$. The results of air-tightness was 12.13 ACH@50 (1/h). The building energy demand ratings and solar energy generation has the possible to be ballanced.

The Study Of Optimum Method About The Architecture, Construction, And Maintenance Through The Construction Of Zero Energy House (제로 에너지 하우스 구축을 통한 설계, 시공, 유지관리 최적 방안에 관한 연구 및 제안)

  • Kim, Sun-Geun;Kwon, Soon-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.42-50
    • /
    • 2014
  • In the thesis, the case of zero energy house construction applied with various Active factors and Passive factors which is the real residence as a standard not a normal experimental residence was evaluated, analyzed, and organized. The thesis can be the base data to construct another similar case of zero energy house.

The Study on Activity Star Problem and Optimum Construction Method Through the Defect Case of Zero Energy House in the Existing Building (기축건물의 제로에너지 하우스 하자 사례를 통한 공종별 문제점 및 최적구축 방안에 관한 연구)

  • Kim, Sun-Geun;Kwon, Soon-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.4
    • /
    • pp.262-270
    • /
    • 2015
  • In this paper existing buildings, not a new buildings and house for living people not just a displaying and a viewing, created by the imagine effect or virtual simulation was applied various Active and Passive elements. After constructing zero-energy houses, through default case happened during operation period it is described problems and solutions about field part, work classification, installation by Location part, and Installation equipment part. Since then, to take advantage of this thesis, it's the purpose of this paper using as the baseline data for building a zero-energy house in another similar case.

Study on the Regenerating Performance of Liquid Desiccant in the Cooling/Dehumidification System able to use a Solar Water Heater in Summer(On the Analysis of Source Effect by the Design of Experiments) (여름철 냉방/제습시스템 중 태양열 온수기를 적용할 수 있는 액체흡수제의 재생성능에 관한 연구(실험계획법에 의한 요인효과 분석에 관하여))

  • Choi, K.H.;Kim, B.C.;Kim, B.J.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • With the possibility of hot water being able to be used as a heating source in a liquid desiccant system, an experimental apparatus for regeneration of the liquid desiccant was set up and series of experiments were conducted in a climate-controlled chamber. This study was performed to ascertain the influences of experimental factors on regenerating performance and to suggest the optimal combination of factors affecting regeneration rate. Furthermore. in order to figure out the contribution ratio of the factors on regenerating performance, a multi-way factorial design among the design of experiments was adopted. According to experimental results, the most influential factor on regenerating performance was temperature of the liquid desiccant and its contribution ratio was about 79.4%. In addition. the optimal operating combination was as follows; $60^{\circ}C$ of solution temperature, $14\ell$/min of solution flow rate, and 190m3/h of air volume.

The Analysis of Energy Consumption Characteristics of the Apartment (공동주택 에너지 소비 경향 분석에 관한 연구)

  • Lee, Hyun-Jung;Park, Sun-Hyo;Bae, Sang-Hwan;Lee, Byung-Seok;Kim, Yang-Sub
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.305-310
    • /
    • 2012
  • In 2009, The Ministry of Land, Transport and Maritime Affairs, Korea opens apartment maintenance fee to public in "Apartment Management Info System". The high energy consumption component of apartment, which is hot water, water, electricity and heating, is released to public on this system. Through this system, apartment energy consumption and greenhouse gas emissions data can be compiled and expected to be accurately analyzed. Energy consumption and greenhouse gas emissions statistics of the apartment are collected being made to reduce energy and gas emissions. However, The accurate survey of energy consumption trends have not been accomplished. The energy consumption and greenhouse gas emissions survey in Apartment should be made first in order to reduce energy consumption. and then the correlation factors analysis which is affecting energy consumption is required. The purpose of this study is to analyze energy consumption characteristics of apartment in Bundann-gu, Seongnam, Korea in monthly, unit area and building built year basis. And then the research can be used as the basis of policy to Reduce energy consumption and greenhouse gas emissions.

  • PDF