In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The design trend implemented the energy insulation, solar PV panels, energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated the physical performance, insulation, airtightness. The second step, we was evaluated energy performance building to design heating and cooling system to combined PV system. As a results, the insulation performance wall was $0.18W/(m^2{\cdot}K)$. The results of air-tightness was 12.13 ACH@50 (1/h). The building energy demand ratings and solar energy generation has the possible to be ballanced.

Keywords

References

  1. Disaster Year Book 2017, Ministry of the Interior and Safety, 2018.
  2. Statistical Yearbook of Natural Disaster 2017, Ministry of the Interior and Safety, 2018.
  3. Misfortune and the safety supervision law, Low No. 15764, Ministry of the interior safety, 2018.
  4. Ryan E. S., Prefab Architecture a Guide to Modular Design and Construction, p. 5. 2010.
  5. Jo, B-H. and Lee, W. I., Global Research - Overcome Market of Modular Architecture (England), Korea Institute of Construction Engineering and Management, Vol. 15, No. 4, p.17, 2014.
  6. Kim, K.H., A Study on the Architectural Responses on the Post-disaster Refugees Housing - Especially on the Open System Modular Housing, Decree of the Inha-university, 2005.
  7. Moon, J. I., A Study on the Planning Method of Temporary Dwellings for Sufferers from a Disaster, Decree of the Yonsei University, 2007.
  8. Infrastructure and Transport R&D Report, Development of a Temporary Living Space Systems Against Disasters, The Ministry of Land, 2014.
  9. Wang, W. C. and Lim, S. H., A Study on the Space Expansion of Temporary Housing to Utilize Modular mock-up, Journal of the Architectural Institute of Korea Planning & Design, Vol. 30, No. 4, pp. 103-111, 2014. https://doi.org/10.5659/JAIK_PD.2014.30.4.103
  10. Standard of Construction Housing Low No. 362, Ministry of the Interior and Safety, 2016.
  11. KS L ISO 9972 Thermal Insulation-Determination of Building Airtightness-Fan Pressurization Method, Korea Agency for Technology and Standards, 2016.
  12. KS F 2278 Standard Test Method for Thermal Resistance for Windows and Doors, Korea Agency for Technology and Standards, 2017.
  13. ISO 10211 Thermal Bridges in Building Construction - Heat Flows and Surface Temperatures - Detailed Calculations, International Standards, 2007.
  14. Building Airtightness Criteria, Korean Institute of Architectural Sustainable Environment and Building Systems, Appendix 2, p. 8, 2013.
  15. Kim, M. K., 2014, Development of Building Energy Standard Model for Home and Business Sector in Seoul, The Seoul Institute.
  16. Kim, M. K., 2013, An Estimation Model of Residential Building Energy Consumption in Seoul, The Seoul Institute.