Abstract

The supply rate of renewable energy has been increasing under the influence of an energy scarcity. Government has supported the use of renewable energy by government subsidies. The operation of renewable may not been operating appropriately, although increasing the use of renewable energy. We found out some problems of the operation of renewable energy and offered some improvements. This research proposes the efficient operation method for the solar thermal system, and proposed operation method was compared and evaluated with existing operation strategy after selecting one building installed solar thermal system. Recently, the interest to renewable energy has increased because of the environmental issues and energy crisis. However the utilization of the renewable energy system is low because of the use of renewable energy system and existing renewable energy system independently, although supply rate of renewable system is increasing. Especially, in the case of solar thermal system heating load is not responsible for the load of hot water supply in many cases. Therefore, suggesting efficient operation plans and evaluations of the energy consumption and efficiency of a solar thermal system is needed.

Keywords

References

  1. Yu S. W., Jung Y. J., Kim S. H., Jo J. H. and Kim Y. S., A study on the optimized control strategies of geothermal heat pump system and absorption chiller-heater, International Journal of Energy Research, 2013
  2. Yu S. W., Jo J. H., Kim Y. S., and Cho Y. H., A study on efficient complex operation of Geothermal Heat pump system and Absorption chiller-heater, Proceedings of the Korean Solar Energy Society, 2012
  3. Kwak H. Y., Kim J. B., Joo H. j., and Kim J. B., Demonstration study on Heating and Hotwater According to Control Condition of Solar System, Journal of the Korean Solar Energy Society, Vol. 26 No. 4, pp. 119-126, 2006
  4. Kwak H. Y and Joo H. J, Thermal Performance of Space heating and Hotwater for Solar System. Proceedings of the Korean Solar Energy Society, 2007
  5. Kang S. H., LeeY. H., Hwang J. H. and Cho Y. H., Theanalysis of the renewable energy supply ratio for the school building applied PV system, Journal of the Korean Solar Energy Society, Vol. 32, No. 2, pp. 55-57, 2012
  6. Kim H. J., Jung Y. J., Seo D. H. and Cho Y. H., A study on the Selection of the VAV System and Proper Minimum Airflow to Improve Energy Efficiency, J. Korean Soc. Living Envirion. Sys, Vol. 20, No. 7, pp. 906-912, 2013
  7. Shin U.C., Baek N.C., Kwak H.C. and Ju H.L., An experimental study on the solar hot water heating system for the dormitory of universuty, Journal of the Korean Solar Energy Society, Vol. 26, No. 2, pp. 103-109, 2006
  8. ASHRA's GUIDELINE 14, For Measurement of energy and demand savings : How to determine what was really saved by the retrofit, Energy Systems Laboratory, Texas A&M University, 2005
  9. TRNSYS 17 Reference Manual, University of Wiconsin Madison, 2010