An Analysis of Critical Management Factors for Construction Failure on the Apartment Structural Framework using FMEA (FMEA 기법을 활용한 공동주택 골조공사의 건설실패 핵심관리요인 분석)

  • Oh, Chi-Don;Park, Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.3
    • /
    • pp.78-88
    • /
    • 2012
  • Previous construction failure researches were focused on the utilization plan based on failure information and development of failure classification. However, it has limitation to set up the plan for prevention of construction failure due to the lack of the number of on-site staffs. In order to prevent effectively construction failure, a prevention plan should be established through quantitative evaluation of failure causes. The purpose of this study is to suggest the assessment method for selection Critical Management Factor(CMF) and to analyze the CMF on the apartment structural framework using FMEA(Failure Mode and Effective Analysis) which is one of the methods of quantitative evaluation. The element of risk evaluation separated degree of failure risk and prevention respectively. The assessment method for selection of CMF can be utilized for planning proactive solutions on the failure, and it can be also selected critical factors about each project phases, type of facility and construction work.

Spalling of Concrete with Compressive strength and heating rates (압축강도 및 가열속도에 따른 콘크리트의 폭렬성상)

  • Choe, Gyeong-Choel;Kim, Gyu-Yong;Yoon, Min-Ho;Lee, Young-Wook;Hwang, Ui-Chul;Yoo, Jae-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.43-44
    • /
    • 2015
  • In this study, spalling property were evaluated from concrete with compressive strengths of 30MPa, 90MPa, 180MPa, applied with fast heating condition(ISO-834 standard heating curve) and slow heatign condition(1℃/min). As a result, the spalling property of concrete was shown differently with compressive and heatign rate. And It could be separated three as non spalling, surface spalling and explosive spalling.

  • PDF

A Study on the Quantifying of Rural Landscape Picture by Fractal Index (프랙탈 지수를 이용한 농촌 경관사진의 정량화 방안 연구)

  • Jeong, Ho-Hyun;Jung, Nam-Su
    • Journal of Korean Society of Rural Planning
    • /
    • v.16 no.3
    • /
    • pp.11-17
    • /
    • 2010
  • With international attention to the rural landscape, there have been landscape management and conservation efforts. Because it contains characteristics of rural area, rural landscape has been recognized as an important component of rurality. With rural amenity resources survey projects launched since 2005, rural landscape categorization and evaluation such as resource value, use value, beauty, originality, traditionality, maintenance are performed by expert questionnaire survey and 100 rural amenity resources are selected. In this study, we performed fractal analysis for developing evaluation system of the rural landscape photographs. In evaluating processes, main and surrounding landscape are separated and fractal indexes are calculated and analyzed with beauty value scoured by experts. Results show that beauty value is not significantly related with fractal index but differences of main and surrounding landscape fractal index.

Cost Breakdown Structure for Reasonable Maintenance of Educational Facilities (교육시설물의 합리적인 유지관리를 위한 비용분류체계)

  • Jeong, Jae-Hyuk;Shin, Han-Woo;Kim, Tae-Hui
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.65-67
    • /
    • 2011
  • It is necessary to the development of the best maintenance system for applying the long-term maintenance plan using the cost breakdown structure in the educational facilities. This study developed the cost breakdown structure for the best maintenance system using the delphi method. For the convenience of maintenance, the maintenance cost breakdown structures are separated into building exterior wall, building inside wall, electric installation, heating installation and outdoor facilities. And these results atomized in each parts. And this study constructed the cost breakdown structure to maintenance's practicality and effectiveness through the expert analysis.

  • PDF

A Study on the Structural Strength Analysis according to the Core Shapes of Aluminum Sandwich Panels (알루미늄 샌드위치패널의 심재 형상에 따른 구조강도해석)

  • 배동명;손정대
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.277-284
    • /
    • 2001
  • Recently, with development of mechanics of materials, as pursuing the high speed of the ships, a demanding of composite construction which satisfies high strength and low weight at the same time is iner casing. A sandwich element is a type of composite construction, which is composed of thin, strong, stiff and relatively high density faces and a think, light, and weaker core material. As 2nd moment is increased by faces is separated from the neutral axis farther, a sandwich element is most effective light structural form. In this paper, the make a comparative study Aluminum Honeycomb Sandwich Panel(AHSP) and Aluminum Pyramid Sandwich Panel(APSP).

  • PDF

A Study on the Adhesion Performance of Acrylate Using Tack Rolling Ball Test (Tack Rolling Ball Test를 활용한 아크릴레이트의 점착 성능에 대한 연구)

  • Yoon, Jun-No;Park, Wan-Goo;Park, Jin-Sang;Choi, Su-Young;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.173-174
    • /
    • 2018
  • In this study, the objective of this study was to evaluate the adhesive characteristics of existing self-adhesive rubber asphalt sheet, butyl sheet and acrylate sheet in a low temperature environment through Tack Rolling Ball Test to obtain basic data on acrylate. As a result of this experiment, in the case of the self-molding rubber asphalt sheet and the butyl rubber sheet, the compound of the sheet was frozen in the low temperature environment and the iron bead was separated. On the other hand, the acrylate sheet did not freeze the acrylate even at 0 ℃, It is confirmed that the measured value is shown by Ball Test.

  • PDF

A Basic Study of the Calculation Model for Shear Connectors of Composite Precast Concrete Beams (합성 PC 보를 위한 전단 보강 계산 모형 기초 연구)

  • Lim, Chaeyeon;Lee, Dong Hoon;Kim, Sun Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.19-20
    • /
    • 2013
  • Green Frame is a column-beam system constructed by composite precast column and beam connected by embedded steel of their. From when the precast concrete beam of Green Frame is installed, until the concrete of slab and connection joint is cured, the self load of beam shall be supported by the embedded steel of it. Therefore, the concrete of beam could be separated from the embedded steel if the shear connector of beam of Green Frame is designed by the code on Structural standard. So, this study suggest an equation for the shear connection of composite precast concrete beams of Green Frame. The result of this study will be used as the main equation of the calculation model for shear connectors of composite precast concrete beams.

  • PDF

Rapid microcement and glycidylacrylate a Case Study on the Improvement of Water Leakage Site Applied to Mixed-use (급결마이크로시멘트 및 글리시딜아크릴레이트를 복합 적용한 누수현장 보수사례)

  • Cho, Il-Kyu;Yuh, Jae Hyung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.241-242
    • /
    • 2019
  • This technology is a water leak repair technology using composite materials of concrete structures that block leakage of structures by injecting rapid microcement into the face of underground concrete to block water and injecting flexible glycidylacrylate. Rapid micro cement system repair materials are mixed with fine fibers to improve the flexural sensitivity of the material and to form a layer that blocks stabilized water at the back of the structure by allowing rapid and tight spatial filling during injection with high cohesion The glycidylacrylate repair material can control the expansion rate, and the external stress also has the characteristic that the form of the material is not destroyed or separated, which can also be applied to vibrating induced structures that produce repetitive fatigue loads, and has an effective durability in saline, alkali, acid (chloric acid, sulfuric acid, nitric acid).

  • PDF

The Bond Strength of Super Retarding Concrete According to Delay Time of Placement (타설지연시간 변화에 따른 초지연제 사용 콘크리트의 부착강도)

  • Han, Soo-Hwan;Sin, Se-Jun;Choi, Yoon-Ho;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.75-76
    • /
    • 2020
  • In this study, in order to check whether the adhesion strength can be secured when installing concrete by mixing super-retarding agents, the splitting tensile strength of the joints of each mold was measured and then analyzed. The results of the experiment showed that the bonding performance of the joint is adversely affected if the installation delay is delayed for more than 24 hours, and that the attachment performance can be secured if the installation is delayed within about 24 hours.

  • PDF

BIM Application Process for Facility Condition Assessment Documentation Work

  • Yoo, Seung Eun;Yu, Jung Ho
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.268-270
    • /
    • 2015
  • Overseas countries' government and facility management industries make efforts to ensure precise and fluent data from building information modeling (BIM). In facility management, a large amount of data and information are necessary to continue the process activities. Facility condition assessment, which is performed to make budget plan for the maintenance and operation requires the related facilities' documentation and information. However, it depends on the owner and the user of the facility to provide accurate and complete information to consultant. The problems as follows: (1) owner and user should provide documents and information, and (2) the consultant cannot verify the provided information. To solve these problems, we suggest a methodology to produce the information for FCA through BIM. First, all of the essential documentation and assessment elements are listed. Next, the documents and elements are separated out, whether they are able to be extracted from BIM or not. Then, the list indicates only the data that is linked with BIM. The suggestion is expected to provide the required information through the connection to BIM with accuracy and completeness and to present another BIM application use for facility management.

  • PDF