• 제목/요약/키워드: Reactive silencer

검색결과 10건 처리시간 0.027초

고전압 COS 퓨즈로부터 방사된 충격성 소음 저감용 반사형 소음기의 설계 (Reactive Silencer Design for Suppressing Impulse Noise from a High Voltage Cut Out Switch Fuse)

  • 송화영;김덕한;이종석;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.951-954
    • /
    • 2006
  • This Study introduces the design of a reactive type silencer for reducing impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level above 150dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study. the reactive type silencers have been utilized. The performance of noise reduction for them can be expressed by insertion loss. The reactive silencers have been tested for 23 different types with each different porosity, hole diameter and depth. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise. The one-stage, two-stage and three-stage reactive type silencers have been shown to have the insertion losses of about from 35dB (A) to 25dB(A).

  • PDF

고전압 COS 퓨즈용 소음기의 소음저감 및 전류차단 성능에 관한 실험적 연구 (An Experimental Study on the Noise Reduction and the Feasibility of Short Current of a Silencer for a High Voltage COS Fuse)

  • 이동훈;송화영
    • 한국소음진동공학회논문집
    • /
    • 제18권7호
    • /
    • pp.783-789
    • /
    • 2008
  • This experimental study describes the noise reduction and the feasibility of short current of a silencer for a high voltage COS(cut out switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the strong impulse noise over 150 dB(A) is generated. For the purpose of the reduction of impulse noise, in this study, the diffuser type and the reactive type silencers have been designed and tested, respectively. And also the electrical test on the short current is performed. From the experimental results, the well designed reactive type silencer has been shown to have the noise reduction of about 20 dB(A). It has been found that the feasibility of short current for the COS fuse is closely related to the porosity of the silencer.

다공판이 내장된 반사형 소음기의 소음저감 성능 (Noise Reduction Performance of a Reactive type Silencer with Perforated Panels)

  • 이선기;이영철;송화영;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1415-1418
    • /
    • 2007
  • When a high voltage COS fuse becomes a short circuit by the over current, the impulse noise over 150 dB(A) with the strong pulse jet is radiated from the COS fuse of an electric transformer. For the purpose of the impulse noise reduction, in this study, a reactive type silencer with perforated panels are considered. The transmission loss of the silencer are calculated by transfer matrix method. The effect of the porosity, the distance between panels, and the number of perforated panel on the sound transmission loss is investigated and discussed.

  • PDF

복합형 반사형 소음기의 음향학적 특성과 설계방법 (Design Methodology of Composite Reactive Silencer Based on Acoustic Analysis)

  • 김양한;최재웅;김영
    • 소음진동
    • /
    • 제1권1호
    • /
    • pp.29-38
    • /
    • 1991
  • The performance of silencer system is controlled by the geometrical parameters such as the relative location of inlet and outlet ports, size of main chamber, and cross sectional geometry of inlet-outlet ports and main chamber of silencer. In addition to these parameters, the presence of mean flow and temperature gradient along the silencer also affects the acoustic characteristics of silencer system. Due to the complexity of silencer, it is not straight forward to design the appropriate silencer system. In this paper, a design methodology based on an oustic analysis of silencer system is proposed ; low frequency and high frequency tuning method.

  • PDF

고전압 COS 퓨즈로부터 방사된 충격성 소음의 전파특성과 저감에 관한 실험적 연구 (An Experimental Study on the Propagation Characteristics and Reduction of Impulse Noises from a High Voltage COS Fuse)

  • 송화영;주경민;이동훈;강내국;정낙헌
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.71-74
    • /
    • 2005
  • This experimental study describes the propagation characteristics and reduction of impulse noises emitted from a high voltage COS(Cut Out Switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current. The peak sound Pressure above 150dB(A) is generated. In this study, an impulse noise generator is designed for generating the impulse noises similar to the noise level of COS fuse, which is utilized to test the noise reduction of a reactive silencer. The reactive silencers have been tested for 10 different types with each different porosity, hole diameter and length. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise and that its performance is closely connected with the porosity and hole diameter.

  • PDF

고전압 COS 퓨즈로부터 방사된 충격성 소음의 지속시간 제어에 관한 실험적 연구 (An Experimental Study on the Control of Duration time of Impulse Noise from a High Voltage COS Fuse)

  • 송화영;김덕한;이종석;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.258-261
    • /
    • 2006
  • This study introduces the control of duration time of impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level over 150 dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study, the reactive type silencer has been utilized. And also electrical interrupting test was experimented. From the experimental results, the reactive type silencer has been shown to have the noise reduction of about 13 dB(A). It has been found that the electrical interception performance of the COS fuse was related to the control of the duration time of impulse noise.

  • PDF

공동주택 화장실 층간 소음 저감기 개발 (Development of silencer for apartment floor between bathroom noise)

  • 김영수;이재국;김창열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.715-721
    • /
    • 2008
  • 공동주택에서의 음환경 성능은 실내환경의 질과 연관시켜 설계단계부터 충분한 검토가 필요한 성능항목이다. '국토해양부'는 '공통주택 성능등급 표시제도'에서 Air Duct를 통해 상하층간 전파되는 소음을 제어하기 위한 대책을 요구하고 있다. 이에 화장실에 적합한 구조 및 재질로 소음 저감기를 개발하고, 소음기 성능평가 장치를 구성하여 이론과 비교평가하고, 실제 현장에 설치 시 적용효과를 분석하였다.

  • PDF

입출구가 연장된 동심형 소음기의 음향해석 (Acoustic Characteristics of Mufflers with an Extended Inlet and Outlet)

  • 이준신
    • 한국음향학회지
    • /
    • 제21권5호
    • /
    • pp.503-509
    • /
    • 2002
  • 입력단 및 출력단이 동심을 이루어 원형 확장관 안으로 연장되어 있는 소음기가 관내 전달 소음저감을 위해 널리 사용되고 있다. 이 소음기의 저주파수 영역에서의 소음저감 효과는 음파 진행 단면의 확장-축소와 입력단 및 출력단의 상대적 위치 등으로 발생되는 소음기의 리액티브 성분에 의해 설명이 된다. 본 논문에서는 입력단 및 출력단에 동심으로 배치된 연장관이 단순 팽창형 소음기 내부에 삽입되어 있는 경우에 대한 음향해석을 수행하였다. 해석방법으로는 음장을 분리좌표계로 표현될 수 있는 몇개의 경계 표면으로 나누고, 각 표면에서의 음압 및 입자속도를 정규화 된 음향 고유 모드로 전개하여 간단한 대수식으로 표현하였다. 이 해석적인 방법을 사용하여 소음기의 투과손실을 예측하였으며, 실험과도 잘 일치함을 관찰할 수 있었다.

원형단순확장관의 입$\cdot$출구 위치와 단면 크기를 고려한 음향해석법 (Acoustic Analysis of Circular Simple Expansion Chamber with Arbitrary Location and Cross-Section Area of Inlet/Outlet)

  • 김봉준;정의봉;황상문
    • 소음진동
    • /
    • 제9권5호
    • /
    • pp.914-921
    • /
    • 1999
  • There are many theoretical investigations to analyze higher order mode of reactive type single expansion chambers with offset inlet/outlet locations. But the conventional method has the restriction that the ratio between the area of inlet(or outlet) pipe and that of chamber must be natural number. In the paper, a new method was suggested to apply the Kim's method to silencer with circular cross-section. Not only the offset location but also the magnitude of cross-section area of inlet/outlet pipe can be considered by the suggested method. The predictions by this new method also compared with those by the finite element method and Munjal's method in order to verify the accuracy of the suggested method presented here.

  • PDF

진동 벽면을 가진 단순 확장형 소음기 모델의 투과손실 특성 해석을 위한 DIRECT BEM-FEM 연성 모델의 적용 (The Application of a Direct Coupled BEM-FEM Model to Predict the TL Characteristics of Simple Expansion Silencers with Vibratory Walls)

  • 최창환;김호용
    • 한국자동차공학회논문집
    • /
    • 제6권6호
    • /
    • pp.24-30
    • /
    • 1998
  • A directly coupled Boundary Element and Finite Element Model was applied to the dynamic analysis of a coupled acoustic silencer with vibratory wall. In this cupled BEM-FEM muffler model, the BEM model was used to discretize the acoustic cavity and the FEM model was used to discretize the vibratory wall structure. Then the BEM model was coupled with the FEM model. The results of the coupled BEM-FEM model for the dynamic analysis of the simple expansion type reactive muffler configurations with flexible walls were verified by comparing the predicted results to analytical solutions. In order to investigate the effects of the muffler's structural flexibility on its transmission loss(TL) characteristics, the results of the coupled BEM-FEM model in conjunction with the four-pole parameter theory were utilized. The muffler's TL characteristics using the BEM-FEM coupled model with flexible walls as compared to other muffler configurations was studied. Finally the muffler's TL values with respect to different wall's thickness are predicted and compared.

  • PDF