• Title/Summary/Keyword: Korean medical student

Search Result 738, Processing Time 0.025 seconds

Study on Attitude of the Elderly among College Students in Physical Therapy through social science convergence (사회과학적 융합을 통한 물리치료학과 학생들의 노인에 대한 태도 조사)

  • Moon, So-Ra;Kim, Myung-Chul;Lee, Min-Su;Kim, Nam-Jae
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.157-163
    • /
    • 2015
  • Purpose is the purpose of this study is to develop medical services for the elderly and qualitatively enhance physical therapy for them by analyzing Korean students' attitudes of the elderly through social science convergence. Methods is a total of 1027 male/female undergraduate students majoring in physical therapy were selected to examine the attitudes of the elderly. T-test, One-way-ANOVA and Scheff test were used. Result is positive attitudes toward the elderly was 46.0%. 51.48% in the population over 30, and 47.52% in the male group was more positive. In addition, when the elderly with no experience in the relevant lecture course (t = -2.035, p = 0.0042) in elderly and when the living experience more positive attitudes (t = 2.951, p = 0.003). Conclusion is education of students in the process of aging of the elderly in a positive standpoint, lectures and hands-on so that you can see the need to change direction.

Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography (CT 검사에서 유리선량계를 이용한 수정체의 비스무트 차폐 효과)

  • Jung, Mi-Young;Kweon, Dae-Cheol;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.307-312
    • /
    • 2009
  • The purpose of our study was to determine the eyeradiation dose when performing routine multi-detector computed tomography (MDCT). We also evaluated dose reduction and the effect on image quality of using a bismuth eye shield when performing head MDCT. Examinations were performed with a 64MDCT scanner. To compare the shielded/unshielded lens dose, the examination was performed with and without bismuth shielding in anthropomorphic phantom. To determine the average lens radiation dose, we imaged an anthropomorphic phantom into which calibrated photoluminescence glass dosimeter (PLD) were placed to measure the dose to lens. The phantom was imaged using the same protocol. Radiation doses to the lens with and without the lensshielding were measured and compared using the Student t test. In the qualitative evaluation of the MDCT scans, all were considered to be of diagnostic quality. We did not see any differences in quality between the shielded and unshielded brain. The mean radiation doses to the eyewith the shield and to those without the shield were 21.54 versus 10.46 mGy, respectively. The lens shield enabled a 51.3% decrease in radiation dose to the lens. Bismuth in-plane shielding for routine eye and head MDCT decreased radiation dose to the lenswithout qualitative changes in image quality. The other radiosensitive superficial organs specifically must be protected with shielding.

  • PDF

Factors Affecting Beneficiary Satisfaction on Financial Aid Program for Cancer Patients in Korea (암환자 의료비 지원사업 대상자의 만족도 관련 요인)

  • Sim, Ju-Ho;Park, Jong-Hyock;Lee, Jung-A;Kim, So-Young;Park, Bo-Ram;Park, Eun-Cheol
    • Health Policy and Management
    • /
    • v.21 no.1
    • /
    • pp.61-76
    • /
    • 2011
  • Limited research has investigated the satisfaction of patients with cancer. This study was performed to explore patients' satisfaction and the related factors. The data were collected by telephone survey for the participants who were beneficiaries on the national financial aid program for cancer patients between January and October in 2009. Student's t-tests and analysis of variance were performed first to determine if the mean satisfaction score differed by the characteristics of study objects, followed by stepwise multiple regression analyses to examine the factors affecting satisfaction. When comparing the relating factors with patients' satisfaction according to the sociodemographic characteristics, the male, old-aged, higher educated, lower cancer stage, lung cancer group showed a significantly higher level of recognition for satisfaction. A public health center, better public relations, recognized more helpful, don't have expectation, put a person to expense, and don't feel pressured for medical cost groups were showed a higher level of recognition for satisfaction. The result of the multiple regression analysis, short waiting time, well known program policy, recognized helping of policy and had the financial burden had significantly influence on the satisfaction of patients with cancer.

How does duration of curing affect the radiopacity of dental materials?

  • Bejeh Mir, Arash Poorsattar;Bejeh Mir, Morvarid Poorsattar
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.89-93
    • /
    • 2012
  • Purpose : Clinicians commonly encounter cases in which it is difficult to determine whether adjacent radiopacities are normal or pathologic. The ideal radiopacity of composite resin is equal to or higher than that of the same thickness of aluminum. We aimed to investigate the possible effects of different curing times on the post-24-hour radiopacity of composite resins on digital radiographs. Materials and Methods : One mm thick samples of Filtek P60 and Clearfil resin composites were prepared and cured with three regimens of continuous 400 mW/$cm^2$ irradiance for 10, 20 and 30 seconds. Along with a 12-step aluminum step wedge, digital radiographs were captured and the radiopacities were transformed to the equivalent aluminum thicknesses. Data were compared by a general linear model and repeated-measures of ANOVA. Results : Overall, the calculated equivalent aluminum thicknesses of composite resins were increased significantly by doubling and tripling the curing times (F(2,8)=8.94, p=0.002). Notably, Bonferroni post-hoc tests confirmed that the radiopacity of the cured Filtek P60 was significantly higher at 30 seconds compared with 10 seconds (p=0.04). Although the higher radiopacity was observed by increasing the time, other comparisons showed no statistical significance (p>0.05). Conclusion : These results supported the hypothesis that the radiopacity of resin composites might be related to the duration of light curing. In addition to the current standards for radiopacity of digital images, defining a standard protocol for curing of dental materials should be considered, and it is suggested that they should be added to the current requirements for dental material.

Usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases

  • Ogura, Ichiro;Nakahara, Ken;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.161-165
    • /
    • 2018
  • Purpose: To evaluate the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Materials and Methods: Ten patients with oral and maxillofacial diseases and 28 volunteers drawn from our student doctors were examined by shear wave elastography with a 14-MHz linear transducer using an Aplio 300 apparatus (Canon Medical Systems, Otawara, Japan). A statistical analysis of the shear elastic modulus(kPa) of healthy tissue (the sublingual gland, submandibular gland, anterior belly of the digastric muscle, and geniohyoid muscle) in the 28 volunteers was performed using 1-way repeated measures analysis of variance with the Tukey honest significant difference test. The maximum shear elastic modulus(kPa) of 8 patients with squamous cell carcinoma (SCC) and 2 patients with benign lesions was evaluated with the Mann-Whitney U test. The analysis used a 5% significance level. Results: The mean shear elastic modulus of the sublingual gland ($9.4{\pm}3.7kPa$) was lower than that of the geniohyoid muscle ($19.2{\pm}9.2kPa$, P=.000) and the anterior belly of the digastric muscle ($15.3{\pm}6.1kPa$, P=.004). The maximum shear elastic modulus of the SCCs($109.6{\pm}14.4kPa$) was higher than that of the benign lesions($46.4{\pm}26.8kPa$, P=.044). Conclusion: Our results demonstrated the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Shear wave elastography has the potential to be an effective technique for the objective and quantitative diagnosis of oral and maxillofacial diseases.

The Relationship Between Addiction to Online Games and Carpal Tunnel Syndrome in College Students (대학생의 온라인게임 중독과 수근관증후군과의 상관성)

  • Park, So-Yeon;Lim, Woo-Teak;Kim, Yu-Jung;Lee, Sung-Woong;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.16 no.1
    • /
    • pp.61-69
    • /
    • 2009
  • The objective of this study was to investigate the relationship between addiction to online games and carpal tunnel syndrome (CTS) in college students. A total of 377 (205 male and 172 female) college students completed an online game addiction scale, a Symptom Severity Scale (SSS), and a Function Status Scale (FSS) for CTS. It was found that five (1.3%) students were diagnosed with an online game addiction, 74 (19.6%) students were diagnosed with a pre-addiction to online games, and 298 (79.0%) students were diagnosed as being average users. The pre-addiction group had significantly higher scores on the SSS than did the average user group (p<.05). The average user group scored significantly lower than did the online game addiction group (p<.05). Symptoms of wrist pain and hand numbness in the daytime were common in the addiction group. There were statistically significant but poor positive relationships between the online game addiction scale and the SSS (r=.312, p<.01), and between the online game addiction scale and the FSS (r=.149, p<.01). The information about online game addiction and CTS identified in this study could contribute to the prevention of online game addiction and CTS in college students.

  • PDF

Unconstrained REM Sleep Monitoring Using Polyvinylidene Fluoride Film-Based Sensor in the Normal and the Obstructive Sleep Apnea Patients (PVDF 필름 기반 센서를 이용한 정상인 및 폐쇄성 수면 무호흡증 환자에서의 무구속적인 렘 수면 모니터링)

  • Hwang, Su Hwan;Yoon, Hee Nam;Jung, Da Woon;Seo, Sang Won;Lee, Yu Jin;Jeong, Do-Un;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.55-61
    • /
    • 2014
  • In sleep monitoring system, polysomnography (PSG) is the gold-standard but previous studies revealed that attaching numerous amount of sensors disturb sleep during the test which is the fundamental disadvantage of PSG. We suggest an unconstrained rapid-eye-movement (REM) sleep monitoring method measured with polyvinylidene (PVDF) film-based sensor for the normal and the obstructive sleep apnea (OSA) patients. Nine normal subjects and seventeen OSA patients have participated in the study. During REM sleep, rate and variability of respiration are known to be greater than in other sleep stages. Based on this phenomena, respiratory signals of participants were unconstrainedly measured using the PVDF-based sensor with the PSG and REM sleep were extracted from the average rate and variability of respiration. In epoch-by-epoch REM sleep detection, proposed method classified REM sleep with an average sensitivity of 72.3%, specificity of 92.5%, accuracy of 88.9%, and kappa statistic of 0.60 compared to the results of PSG. Student's t-test showed no significant difference between the results of normal and OSA group. This method is potentially applicable to REM sleep detection in homing environment or ambulatory monitoring.

The Effect of the Weight of a Backpack on Craniovertebral Angle and Neck Muscle Activities on Some University Students (백팩 무게가 일부 대학생의 머리척추각과 목 근활성도에 미치는 영향)

  • Park, Cheon-jun;An, Duk-hyun
    • Physical Therapy Korea
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2020
  • Background: A backpack is available equipment for moving some objects. Most studies have found that the appropriate weight limit of backpack for students is between 10% to 15% of their body weight (BW). However, Some students should carry a backpack heavier than 15% of BW. Therefore, It is associated with abnormal shoulder and neck posture on students. Objects: This study tested the effects that various amounts of weight carried by university students in their backpacks had on their cervical posture and electromyography of neck muscle. Methods: The subjects consisted of 12 students (6 male, 6 female) in university. There were three loading conditions tested: no backpack, a backpack that weighed 10% and 15% of the student's BW. The dependent variables were the craniovertebral angle (tragus to C7) and the neck muscle activities (sternocleidomastoid, upper trapezius). All 12 subjects were asked to walk while wearing a backpack for 5 minutes and were then instructed to rest for 2 minutes. Results: When assessing the craniovertebral angle, the results of this study were significantly decreased in the order of 0%, 10%, and 15%. And then, there were significantly increased electromyography of neck muscles that comparison of the weight of 10% and 15% on 0%. It was found that as the weight of the backpack increased, the craniovertebral angle decreased (p < 0.05) and the muscle activities increased (upper trapezius p = 0.012, sternocleidomastoid p = 0.013). Conclusion: Our study recommended that some students shouldn't carry on over the 15% backpack of own weight, and also they should distribute backpack load to equal on body for optimal posture.

Assessment of radiopacity of restorative composite resins with various target distances and exposure times and a modified aluminum step wedge

  • Mir, Arash Poorsattar Bejeh;Mir, Morvarid Poorsattar Bejeh
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.163-167
    • /
    • 2012
  • Purpose: ANSI/ADA has established standards for adequate radiopacity. This study was aimed to assess the changes in radiopacity of composite resins according to various tube-target distances and exposure times. Materials and Methods: Five 1-mm thick samples of Filtek P60 and Clearfil composite resins were prepared and exposed with six tube-target distance/exposure time setups (i.e., 40 cm, 0.2 seconds; 30 cm, 0.2 seconds; 30 cm, 0.16 seconds, 30 cm, 0.12 seconds; 15 cm, 0.2 seconds; 15 cm, 0.12 seconds) performing at 70 kVp and 7 mA along with a 12-step aluminum stepwedge (1 mm incremental steps) using a PSP digital sensor. Thereafter, the radiopacities measured with Digora for Windows software 2.5 were converted to absorbencies (i.e., A=-log (1-G/255)), where A is the absorbency and G is the measured gray scale). Furthermore, the linear regression model of aluminum thickness and absorbency was developed and used to convert the radiopacity of dental materials to the equivalent aluminum thickness. In addition, all calculations were compared with those obtained from a modified 3-step stepwedge (i.e., using data for the 2nd, 5th, and 8th steps). Results: The radiopacities of the composite resins differed significantly with various setups (p<0.001) and between the materials (p<0.001). The best predicted model was obtained for the 30 cm 0.2 seconds setup ($R^2$=0.999). Data from the reduced modified stepwedge was remarkable and comparable with the 12-step stepwedge. Conclusion: Within the limits of the present study, our findings support that various setups might influence the radiopacity of dental materials on digital radiographs.

Effects of a Sensory Stimulation on Weight Gain in Premature Infants (감각자극이 미숙아의 체중증가에 미치는 영향)

  • Lee Kun Ja;Cho Kyoul Ja
    • Child Health Nursing Research
    • /
    • v.5 no.3
    • /
    • pp.250-261
    • /
    • 1999
  • This study has been conducted on the nonequivalent control group Pretest-posttest design in quasi experimental basis and newly born premature infants from intensive care unit of G Medical University Hospital in Inchon Metropolitan were selected in two groups of 21 infants each. The first group for experimental and the other for control. Data has been collected form October 30, 1997 to August 29, 1998. For the experimental group tactile and kinesthetic stimulation was applied 2 times a day for 10 days(10:00~ll:00 hours in the morning and 17:00~18:00 in the afternoon). As, a weight weighing instrument, electronic indicator scale(Cas Co. korea) was used. Collected data were analyzed with the SAS program using x²-test, student t-test, repeated measures ANOVA, Pearson correlated coefficient and Stepwise multiple regression. The result were as follow. 1. As for the daily weight gain, the experimental group showed first change in weight and this group also showed higher weight in the average weight than the control group. Statistically, however. there was no significant factor between the two groups. 2. In the correlation between general characteristics and weight gain, gestation Period. apgar score, admission Period before study, N.P.O. period after birth, recovery Period to birth weight showed statistical significance negative correlation with weight gam in the experimental group than control group. 3. In the factor with affected the weight gain by general characteristics showed recovery period to birth weight and head circumference in the experimental group, control group showed recovery period to birth weight, N. P. O. period after birth. admission period before study, feeding amount, weight of study. In conclusion. the sensory stimulation in this study showed a Positive aspect through there was no statistical significance in the weight gam. Tn the correlation of general characteristics and weight gam showed statistical significance negative correlation The main factor which affected the weight gain by general characteristics showed recover period to birth weight.

  • PDF