DOI QR코드

DOI QR Code

Assessment of radiopacity of restorative composite resins with various target distances and exposure times and a modified aluminum step wedge

  • Received : 2012.04.12
  • Accepted : 2012.07.23
  • Published : 2012.09.30

Abstract

Purpose: ANSI/ADA has established standards for adequate radiopacity. This study was aimed to assess the changes in radiopacity of composite resins according to various tube-target distances and exposure times. Materials and Methods: Five 1-mm thick samples of Filtek P60 and Clearfil composite resins were prepared and exposed with six tube-target distance/exposure time setups (i.e., 40 cm, 0.2 seconds; 30 cm, 0.2 seconds; 30 cm, 0.16 seconds, 30 cm, 0.12 seconds; 15 cm, 0.2 seconds; 15 cm, 0.12 seconds) performing at 70 kVp and 7 mA along with a 12-step aluminum stepwedge (1 mm incremental steps) using a PSP digital sensor. Thereafter, the radiopacities measured with Digora for Windows software 2.5 were converted to absorbencies (i.e., A=-log (1-G/255)), where A is the absorbency and G is the measured gray scale). Furthermore, the linear regression model of aluminum thickness and absorbency was developed and used to convert the radiopacity of dental materials to the equivalent aluminum thickness. In addition, all calculations were compared with those obtained from a modified 3-step stepwedge (i.e., using data for the 2nd, 5th, and 8th steps). Results: The radiopacities of the composite resins differed significantly with various setups (p<0.001) and between the materials (p<0.001). The best predicted model was obtained for the 30 cm 0.2 seconds setup ($R^2$=0.999). Data from the reduced modified stepwedge was remarkable and comparable with the 12-step stepwedge. Conclusion: Within the limits of the present study, our findings support that various setups might influence the radiopacity of dental materials on digital radiographs.

Keywords

References

  1. International Organization for Standardization. ISO 4049: 2009. Dentistry-Polymer based restorative materials, 4th ed. Geneva: ISO; 2009.
  2. Sur J, Endo A, Matsuda Y, Itoh K, Katoh T, Araki K, et al. A measure for quantifying the radiopacity of restorative resins. Oral Radiol 2011; 27 : 22-7. https://doi.org/10.1007/s11282-010-0055-4
  3. Wenzel A, Hintze H, Hørsted-Bindslev P. Discrimination between restorative dental materials by their radiopacity measured in film radiographs and digital images. J Forensic Odontostomatol 1998; 16 : 8-13.
  4. Pedrosa RF, Brasileiro IV, dos Anjos Pontual ML, dos Anjos Pontual A, da Silveira MM. Influence of materials radiopacity in the radiographic diagnosis of secondary caries: evaluation in film and two digital systems. Dentomaxillofac Radiol 2011; 40 : 344-50. https://doi.org/10.1259/dmfr/93764866
  5. Martinez-Rus F, Garcia AM, de Aza AH, Pradies G. Radiopacity of zirconia-based all-ceramic crown systems. Int J Prosthodont 2011; 24 : 144-6.
  6. Wadhwani C, Hess T, Faber T, Piñeyro A, Chen CS. A descriptive study of the radiographic density of implant restorative cements. J Prosthet Dent 2010; 103 : 295-302. https://doi.org/10.1016/S0022-3913(10)60062-5
  7. Ergücü Z, Türkün LS, Onem E, Güneri P. Comparative radiopacity of six flowable resin composites. Oper Dent 2010; 35 : 436-40. https://doi.org/10.2341/09-340-L
  8. Tasdemir T, Yesilyurt C, Yildirim T, Er K. Evaluation of the radiopacity of new root canal paste/sealers by digital radiography. J Endod 2008; 34 : 1388-90. https://doi.org/10.1016/j.joen.2008.08.008
  9. Bodrumlu E, Gungor K. Radiopacity of an endodontic core material. Am J Dent 2009; 22 : 157-9.
  10. Rasimick BJ, Gu S, Deutsch AS, Musikant BL. Measuring the radiopacity of luting cements, dowels, and core build-up materials with a digital radiography system using a CCD sensor. J Prosthodont 2007; 16 : 357-64. https://doi.org/10.1111/j.1532-849X.2007.00209.x
  11. Gu S, Rasimick BJ, Deutsch AS, Musikant BL. Radiopacity of dental materials using a digital X-ray system. Dent Mater 2006; 22 : 765-70. https://doi.org/10.1016/j.dental.2005.11.004
  12. Tanomaru-Filho M, da Silva GF, Duarte MA, Gonçalves M, Tanomaru JM. Radiopacity evaluation of root-end filling materials by digitization of images. J Appl Oral Sci 2008; 16 : 376-9. https://doi.org/10.1590/S1678-77572008000600004
  13. Rasimick BJ, Shah RP, Musikant BL, Deutsch AS. Radiopacity of endodontic materials on film and a digital sensor. J Endod 2007; 33 : 1098-101. https://doi.org/10.1016/j.joen.2007.05.005
  14. Baksi BG, Ermis RB. Comparison of conventional and digital radiography for radiometric differentiation of dental cements. Quintessence Int 2007; 38 : e532-6.
  15. Catelan A, Padilha AC, Salzedas LM, Coclete GA, dos Santos PH. Effect of radiotherapy on the radiopacity and flexural strength of a composite resin. Acta Odontol Latinoam 2008; 21 : 159-62.
  16. Poorsattar Bejeh Mir A, Poorsattar Bejeh Mir M. How does duration of curing affect radiopacity of dental materials? Imaging Sci Dent 2012; 42 : 89-93. https://doi.org/10.5624/isd.2012.42.2.89
  17. Watts DC, McCabe JF. Aluminium radiopacity standards for dentistry: an international survey. J Dent 1999; 27 : 73-8. https://doi.org/10.1016/S0300-5712(98)00025-6
  18. Nomoto R, Mishima A, Kobayashi K, McCabe JF, Darvell BW, Watts DC, et al. Quantitative determination of radioopacity: equivalence of digital and film X-ray systems. Dent Mater 2008; 24 : 141-7. https://doi.org/10.1016/j.dental.2007.08.005
  19. Vivan RR, Ordinola-Zapata R, Bramante CM, Bernardineli N, Garcia RB, Hungaro Duarte MA, et al. Evaluation of the radiopacity of some commercial and experimental root-end filling materials. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108 : e35-8.
  20. White SC, Pharoah MJ. Oral radiology: principles and interpretation. 6th ed. St. Louis: Mosby-Elsevier; 2009. p. 84.

Cited by

  1. Evaluation of the Radiopacity of Contemporary Luting Cements by Digital Radiography vol.29, pp.4, 2013, https://doi.org/10.14368/jdras.2013.29.4.377
  2. A newin vitromethod to evaluate radio-opacity of endodontic sealers vol.44, pp.5, 2012, https://doi.org/10.1259/dmfr.20140422
  3. Evaluation of the Radiopacities of Bulk-fill RestorativesUsing Two Digital Radiography Systems vol.40, pp.5, 2012, https://doi.org/10.2341/14-074-l
  4. Mineral Trioxide Aggregate—A Review of Properties and Testing Methodologies vol.10, pp.11, 2012, https://doi.org/10.3390/ma10111261
  5. Effect of filler characteristics on radiopacity of experimental nanocomposite series vol.32, pp.14, 2012, https://doi.org/10.1080/01694243.2018.1433117
  6. A Radiolucent Electromagnetic Tracking System for Use with Intraoperative X-ray Imaging vol.21, pp.10, 2021, https://doi.org/10.3390/s21103357