References
- Yoo BC, Kweon DC, Lee JS, Jang KJ, Jeon SH, Kim YS : Comparison radiation dose of z-axis automatic tube current modulation technique with fixed tube current multi-detector row CT scanning of lower extremity venography, J Radiat Prot, 32(3), 123-133, 2007
- Tweed JJ, Davies ML, Faulkner K, Rawlings DJ, Forster E : Patient dose and associated risk due to radiological investigation of the internal auditory meatus, Br J Radiol, 64, 447-451, 1991 https://doi.org/10.1259/0007-1285-64-761-447
- Lund E, Halaburt H : Irradiation dose to the lens of the eye during CT of the head, Neuroradiology, 22, 181-184, 1982 https://doi.org/10.1007/BF00341246
- Geleijns J, Van Unnik JG, Zoetelief J, Zweers D, Broerse JJ : Comparison of two methods for assessing patient dose from computer tomography, Br J Radiol, 67, 360-365, 1994 https://doi.org/10.1259/0007-1285-67-796-360
- Poletti JL : Patient doses from CT in New Zealand and a simple method for estimating effective dose, Br J Radiol, 69, 432-436, 1996 https://doi.org/10.1259/0007-1285-69-821-432
- Maclennan AC, Hadley DM : Radiation dose to the lens from computed tomography scanning in a neuroradiology department, Br J Radiol, 68, 19-22, 1995 https://doi.org/10.1259/0007-1285-68-805-19
- Nishizawa K, Maruyama T, Takayama M, Okada M, Hachiya J, Furuya Y : Determinations of organ doses and effective dose equivalents from computed tomographic examination, Br J Radiol, 64, 20-28, 1991 https://doi.org/10.1259/0007-1285-64-757-20
- Dalrymple GV, Goulden ME, Kollmorgen GM, Vogel H : Medical Radiation Biology, Philadelphia, WB Saunders, 235, 1973
- Nishizawa K, Maruyama T, Takayama M, Okada M, Hachiya J, Furuya Y : Determinations of organ doses and effective dose equivalents from computed tomographic examination, Br J Radiol, 64, 20-28, 1991 https://doi.org/10.1259/0007-1285-64-757-20
- Rothenberg LN, Pentlow KS : Radiation dose in CT, Radiographics, 12, 1225-1243, 1992 https://doi.org/10.1148/radiographics.12.6.1439023
- Rah JE, Shin DO, Hong JY, Kim HS, Lim CI, Jeong HG, Suh TS : Study on dosimetric properties of radiophotoluminescent glass rod detector, J Korea Asso Radiat Prot, 31(4), 181-186, 2006
- Technical report : Explanation material of RPL glass dosimeter : small element System, Tokyo, Japan ; 2000
- European Commission. European Guidelines on quality criteria for computed tomography. Report EUR 16262EN. Luxembourg : Office for official publications of the European Commission, 66-78, 1999
- Fricke BL, Donnelly LF, Frush DP, Yoshizumi T, Varchena V, Poe SA, Lucaya J : In-plane bismuth breast shields for pediatric CT : effects on radiation dose and image quality using experimental and clinical data, AJR Am J Roentgenol, 180(2), 407-11, 2003 https://doi.org/10.2214/ajr.180.2.1800407
- Yilmaz MH, Albayram S, Yasar D, Ozer H, Adaletli I, Selcuk D, Akman C, Altug A : Female breast radiation exposure during thorax multidetector computed tomography and the effectiveness of bismuth breast shield to reduce breast radiation dose, J Comput Assist Tomogr, 31(1), 138-42, 2007 https://doi.org/10.1097/01.rct.0000235070.50055.e6
- Hopper KD, Neuman JD, King SH, Kunselman AR : Radioprotection to the eye during CT scanning, AJNR Am J Neuroradiol, 22(6), 1194-8, 2001
- Geleijns J, Van Unnik JG, Zoetelief J, Zweers D, Broerse JJ : Comparison of two methods for assessing patient dose from computed tomography, Br J Radiol, 67, 360-365, 1994 https://doi.org/10.1259/0007-1285-67-796-360
- Hidajat N, Maurer J, Schroder RJ et al. : Relationship between physical dose quantities and patient dose in CT, Br J Radiol, 72, 556-561, 1999 https://doi.org/10.1259/bjr.72.858.10560337
- Hopper KD, Neuman JD, King SH, Kunselman AR : Radioprotection to the eye during CT scanning, AJNR Am J Neuroradiol, 22(6), 1194-1198, 2001
- Yeoman LJ, Howarth L, Britten A, Cotterill A, Adam EJ : Gantry angulation in brain CT : dosage implications, effect on posterior fossa artifacts, and current international practice, Radiology, 184, 113-116, 1992 https://doi.org/10.1148/radiology.184.1.1609066
- McLaughlin DJ, Mooney RB : Dose reduction to radiosensitive tissues in CT. Do commercially available shields meet the users' needs? Clin Radiol, 59, 446-450, 2004 https://doi.org/10.1016/j.crad.2003.10.016