• Title/Summary/Keyword: Input Power measurement

Search Result 334, Processing Time 0.025 seconds

A Study on Improvement of Linearity and Efficiency Compensation in a Power Amplifier Using Asymmetical Doherty Structure (비대칭 Doherty 구조를 이용한 전력 증폭기의 선형성 개선과 효율 보상에 관한 연구)

  • Kang, Dong-Jin;Han, Ki-Kwan;Lee, Ho-Woong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.1
    • /
    • pp.63-69
    • /
    • 2010
  • In this paper, a new design method of asymmetrical configuration of main amplifier and peaking amplifier using changed bias point is proposed for excellent linearity, instead of the conventional Doherty structure. We have utilized the uneven wilkinson power divider for the unequal power drive at the input network of amplifiers. And we proposed a compensating method of the decreasing efficiency due to improving linearity using 3-stage Doherty structures. From the simulation results of asymmetrical Dohertry power amplifier and asymmetrical 3-stage Doherty power amplifier with uneven power drive are implemented. From the implementation and measurement results of the each amplifier, IMD characteristics have -55 dBc as the good efficiency of 13% compensates the decreased entire efficiency due to the improving linearity characteristics.

  • PDF

Design of High Efficiency and Linearity Doherty Power Amplifier Using Adaptive Bias Technique and DGS for Wibro Applications (적응형 바이어스 기법과 DGS를 이용한 와이브로용 고효율 고선형 도허티 전력증폭기 설계)

  • Oh, Chung-Gyun;Son, Sung-Chan
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.8 no.1
    • /
    • pp.12-17
    • /
    • 2009
  • In this paper, We play it for the purpose of study about the power amplifier which applied DGS and adaptive bias circuit structure to general Doherty amplifier for the efficiency of a RF power amplifier and a linearity improvement in the WiBro band. As for the IMD3, 3.4dBc was improved with -26.3dBc when we did the measurement result existing Doherty power amplifier and comparison of the Doherty power amplifier which applied an adaptive bias circuit and the DGS which proposed in this paper, and the mean power efficiency verified what was increased in 37%. Also, we were able to know PAE of 36.6% with output power 34.0dBm in P1dB when magnitude of an input signal was 25.6dBm. we did 6dB back off in output P1dB in order to confirm the ACPR which was a nonlinear characteristic and measured the ACPR. we showed the -34.55dBc which was a value of -34.5dBc or below in the 4.77MHz off-set that was a transmission standard. Therefore, we were able to know that we were satisfied with a spectrum mask standard.

  • PDF

A Study on Power Dissipation of The Microprocessor Based on Trace-Driven Simulation (명령어 자취형 모의실험을 기반으로 하는 마이크로프로세서의 전력 소비에 대한 연구)

  • Lee, Jongbok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.191-196
    • /
    • 2016
  • Recently, power dissipation is a very significant issue not only in embedded systems and mobile devices but also in high-end modern processors. Especially, by the prevalent use of smart phones and tablet PCs, low power consumption of microprocessors is requisite. In this paper, a fast power measurement tool for a high performance microprocessor based on the trace-driven simulator has been developed. The power model of the microprocessor consists of complex combinational circuits, array structures, and CAM structures. Using SPEC 2000 benchmarks as input, the trace-driven simulation has been performed to estimate the average power dissipation of each program.

A Study on Fault Diagnosis of Boiler Tube Leakage based on Neural Network using Data Mining Technique in the Thermal Power Plant (데이터마이닝 기법을 이용한 신경망 기반의 화력발전소 보일러 튜브 누설 고장 진단에 관한 연구)

  • Kim, Kyu-Han;Lee, Heung-Seok;Jeong, Hee-Myung;Kim, Hyung-Su;Park, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1445-1453
    • /
    • 2017
  • In this paper, we propose a fault detection model based on multi-layer neural network using data mining technique for faults due to boiler tube leakage in a thermal power plant. Major measurement data related to faults are analyzed using statistical methods. Based on the analysis results, the number of input data of the proposed fault detection model is simplified. Then, each input data is clustering with normal data and fault data by applying K-Means algorithm, which is one of the data mining techniques. fault data were trained by the neural network and tested fault detection for boiler tube leakage fault.

An Improved Feed-Forward Controller for the Parallel Operation of a Single-Phase PWM Converter in High-Speed Trains (고속철도용 단상 PWM 컨버터의 병렬운전을 위한 개선된 전향제어기)

  • Park, Byoung-Gun;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.226-234
    • /
    • 2010
  • This paper proposes an improved feed-forward controller that calculates the gain value by estimating the changed boost inductance in practical operating condition of transformer. The boost inductance is estimated by the measurement of input current and voltage. The estimated boost inductance is optimized by the least square method. The proposed feed-forward controller can be achieved the robust control through the gain value calculating the estimated boost inductance despite of the changed condition of transformer and can minimize the interference phenomenon by reducing the harmonics of input current. The validity of proposed technique is verified through the simulation and experiment.

Analysis of Polarization Properties of Optical Isolator for Fiber Laser

  • Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil;Cho, Kyung-Jae;Kang, Sung-Hak
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.6
    • /
    • pp.241-244
    • /
    • 2011
  • An isolator transmits light in the forward direction and blocks light from passing in the reverse direction. It is regarded an essential optical component in medical, industrial, and research lasers for blocking reflection beams that cause optical damage and noise. It is also used as a communicative light intensifier to expand the lifespan of devices and enhance transmission quality. This study analyzed the characteristics of the core components in the construction of a polarization-independent isolator, namely, the walk-off polarizer and the Faraday rotator. Measurement of the extinction ratio of the resultant walk-off polarizer revealed that the ratio between the vertical and horizontal rays was 1,050:1 with a laser output of 0.032 W and 1,010:1 with a laser output of 2.68 W, thus presenting ratios similar to 1,000:1. In addition, the walk-off polarizer and Faraday rotator constructed in this study were used to compare output changes according to changes in power of input light and to check the penetration ratio. Results from the study presented variations in output value according to changes in power of input light. However, the average penetration ratio remained relatively consistent (~81.4%).

A Study on Accelerated Fatigue Life Testing for Industrial Inverter (산업용 인버터의 가속 피로수명 평가에 관한 연구)

  • Lee, Sanghoon;Kim, Won-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.6
    • /
    • pp.67-73
    • /
    • 2022
  • Industrial inverters are used in a variety of fields for electric power supply. They may be exposed to vibration and heat once they are installed. This study focused on a framework of accelerated life testing of an industrial inverter considering fatigue damage as the primary source of deterioration. Instead of analyzing detailed failure mechanisms and the product's vulnerability to them, the potential of fatigue failure is considered using the fatigue damage spectrum calculated from the environmental vibration signals. The acceleration and temperature data were gathered using field measurement and spectral analysis was conducted to calculate the vibration signal's power spectral density (PSD). The fatigue damage spectrum is then calculated from the input PSD data and is used to design an accelerated fatigue life testing. The PSD for the shaker table test is derived that has the equivalent fatigue damage to the original input signal. The tests were performed considering the combined effect of random vibration and elevated temperature, and the product passed all the planned tests. It was successfully demonstrated that the inverter used in this study could survive environmental vibration up to its guarantee period. The fatigue damage spectrum can effectively be used to design accelerated fatigue life testing.

Design & Fabrication of a Feedforward Power Amplifier for 900 MHz Band RFID Readers (900 MHz 대역 RFID 리더기용 Feedforward형 선형 전력 증폭기 설계 및 제작)

  • Jung, Byoung-Hee;Chae, Gyu-Sung;Kim, Chang-Woo
    • Journal of Advanced Navigation Technology
    • /
    • v.8 no.2
    • /
    • pp.184-190
    • /
    • 2004
  • A feedforward linear power amplifier (FLPA) has been developed for UHF-band RFID reader applications. The main and error amplifiers are composed of a 2 stage so that linearity of the FLPA can be improved. The FLPA has been implemented on an FR-4 substrate (Er=4.7 and thickness=0.8 mm) with 3-dB and 10-dB hybrid couplers for input/output power divider and combiner. For 2-tone measurement (input level=-11 dBm at $f_1$=915 MHz and $f_2$=916 MHz), the FLPA exhibits a -18.52 dBm of $IMD_3$, which indicates that $IMD_3$ cancellation with feedforward loop is more than 27 dB. From 890 to 960 MHz, 1-dB gain compression output power and power gain of the FLPA are higher than 30 dBm and 40 dB, respectively.

  • PDF

Parameter Measurement Method for Super Capacitor Failure Diagnosis and Application of Voltage Sag Compensation System Using Super Capacitor (수퍼 커패시터의 고장진단을 위한 파라미터의 측정기법과 순시전압강하 보상장치에의 응용사례)

  • Shon, Jin-Geun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.6
    • /
    • pp.173-179
    • /
    • 2009
  • Recently, the super capacitor(EDLC) which has drawn attention as a new energy storage element has a lot of advantage such as no maintenance, long lifetime and quick charge/discharge characteristics with large current. The objective of this paper is propose a parameter measurement method to detect the changes in equivalent series resistor (ESR) and the capacitance value of a super capacitor in order to analysis the internal characteristic and worn-out state of a super capacitor. For proposed method, only the capacitor voltage measurement using simple analog switch is required. In addition, experimental results of voltage sag compensation system in order to compensate the input voltage drop during short-term power interruption adopted super capacitor are presented.

  • PDF

CMOS Linear Power Amplifier with Envelope Tracking Operation (Invited Paper)

  • Park, Byungjoon;Kim, Jooseung;Cho, Yunsung;Jin, Sangsu;Kang, Daehyun;Kim, Bumman
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • A differential-cascode CMOS power amplifier (PA) with a supply modulator for envelope tracking (ET) has been implemented by 0.18 ${\mu}m$ RF CMOS technology. The loss at the output is minimized by implementing the output transformer on a FR-4 printed circuit board (PCB). The CMOS PA utilizes the $2^{nd}$ harmonic short at the input to enhance the linearity. The measurement was done by the 10MHz bandwidth 16QAM 6.88 dB peak-to-average power ratio long-term evolution (LTE) signal at 1.85 GHz. The ET operation of the CMOS PA with the supply modulator enhances the power-added efficiency (PAE) by 2.5, to 10% over the stand-alone CMOS PA for the LTE signal. The ET PA achieves a PAE of 36.5% and an $ACLR_{E-UTRA}$ of -32.7 dBc at an average output power of 27 dBm.