• Title/Summary/Keyword: Imaging equipments

Search Result 72, Processing Time 0.025 seconds

The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC (자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향)

  • Yoon, Seok-Hwan;Choi, Jun-Gu;Han, Dong-Kyoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.23-30
    • /
    • 2007
  • This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detertor acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AWC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used,the dose necessary for image acquisition decreased as the grid ratio became higher and the distance became further. but detector acquisition dose was not reduced when in applied AEC. When purchasing digiral medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the equipments. Radiography error made by radiation technologist and unnenessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

  • PDF

The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System (적외선 열화상 카메라를 이용한 수전설비 온도분포해석)

  • Jeong, Seung-Cheon;Lim, Yeung-Bae;Kim, Jong-Seo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF

Development of Remote Data Analysis System for the Joint Use of Equipments (분석기기지원을 위한 원격 데이터 분석 시스템 개발)

  • 최인식
    • Journal of Korea Technology Innovation Society
    • /
    • v.2 no.3
    • /
    • pp.94-106
    • /
    • 1999
  • In Korea Basic Science Institute(KBSI) the remote data analysis system is developed for the joint use of advanced equipments. This system enables the researchers to access the datas which are produced at KBSI and analyse them by Java program on the Web,. Except Web browser such as Internet Explorer or Netscape Navigator no additional softwares are required for analysing data. We have developed remote data analysis systems for five major equipments which KBSI supports for the researchers, The systems which are developed are those for NMR spectrometer High Reso-lution Tandem mass Spectrometer Microscopic Imaging System DNA Sequencer and Natural Ra-dioactivity Measruement System, These programs work on any computer platform and any operat-ing system only if the internet is available. This remote data analysis system will be served as a part of Collaboratory the remote collaborative system.

  • PDF

Manufacture of Versatile Phantom for the Daily Quality Assurance of Radiation Therapy Equipments (방사선치료 장비들의 매일 정도관리를 위한 다용도 모형의 제작)

  • Cha, Dong-Soo;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.59-64
    • /
    • 2010
  • We examined the accuracy and efficiency of phantom by applying the designed phantom in order to check daily quality assurance easily by objective criteria and to confirm daily quality assurance of linear accelerator, simulator, and CT-simulator. The results of 10 weeks of linear accelerator output dose using American Association of Physicists in Medicine(AAPM) daily quality assurance guide were measured within ${\pm}1%$ of error. Mechanical check of laser alignment, optical distance indicator(ODI), CT scanner laser and alignment of gantry lasers with the center of imaging plane were measured within ${\pm}1mm$. Daily average working time for daily quality assurance of radiation therapy equipments was 38 minutes. The designed phantom was easy to install and daily quality assurance was possible with only one installation. The aspects reproducibility and efficiency as well as accuracy of quality assurance were excellent.

  • PDF

The Relationship of Radiation Dose and Image Quality According to the Condition of Chest PA

  • Son, Jin-Hyun;Min, Jung-Whan;Kang, Byung-Sam;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.165-169
    • /
    • 2011
  • The purpose of this study is to compare the measurement result of radiation dose by using standard thoracic phantom and ionization chamber to advice proposal in the shooting condition of chest PA projection at hospitals recently. And to understand the change between radiation dose and resolution in different conditions. The period this study was from August 2010 to September 2010 and the subjects of the study was 3 general hospitals, 4 personal hospitals and 1 laboratory at the college. Finally we study with 6 DR, 1 CR, and 4 F/S equipments. Most hospitals met advice proposal, but some of the hospitals exceed advice dose from the result of our study. We can lower radiation dose about 25% when kVp is lowered about 20% in DR equipment. And we can lower radiation dose about 50% when mAs is lowered about 35%. The image quality was similar to the original in the study. Most hospitals which exceed advice dose were personal hospitals. The reason why it happened is that radiation dose for chest PA projection at personal hospitals is higher than general hospitals and the personal hospitals' equipments are older than general hospitals' equipments. We guess that patients' radiation dose of chest PA projection can be lowered from the result.

  • PDF

A Study on Improving the Position Accuracy of the Magnetic North used in Surveillance Imaging Equipments (통합형 구조의 감시정찰 영상장비에서 자북의 위치 정확도 개선에 관한 연구)

  • Shin, Young-Don;Lee, Jae-Chon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.219-228
    • /
    • 2013
  • The surveillance imaging equipments are functioning to observe the shape of the target in real time or to measure its location precisely. The roles of such equipments are becoming more important in today's weapon systems.The aforementioned imaging equipments can be classified based on the modes of operations such as fixed, installed on cars, or composite of those. Also, according to different concepts of sensor operation, a separate type uses independent housing for each sensor whereas in a composite type a set of multiple sensors are housed into a unit altogether. The sensors in general have magnetism, thereby introducing the possible negative effects, particularly in the composite types, in locating the reference position, which is carried out by the digital compass. The use of shielding material/housing could be an option but results in increased weight and reduced portability, restricting its use in composite type equipments. As such, the objective of this paper is to study on how to reduce such magnetic effects on the position location. To do so, in the absence of magnetic shielding, a variety of sensor positions were first modeled. By combing the result with the fact that the functions of PAN & Tilt are used in the equipments, a new position location algorithm is proposed. The use of the new algorithm can automate the position location process as compared to the manual process of the existing approach. In the algorithm developed, twelve locations are measured in connection with both the azimuth and elevation angles in comparison to the six locations alone around the azimuth angle. As a result, it turns out that the measurement range has been widened but the measurement time reduced. Also, note that the effect of errors the operators may make during measurement could be reduced.

Energy efficiency standard for imaging equipments using electrophotograph printing (전자사진 기술을 사용하는 이미징 장치의 에너지 효율 기준 연구)

  • Park, Jun-Young;Yoon, Wonsik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2433-2442
    • /
    • 2014
  • In this paper, an efficiency grade standard for imaging equipments using electrophotograph printing such as a printer, copier, fax, and MFD (Multi Function Device) is studied. By emphasizing domestic standby power reduction program's problem, and proposing the necessity of efficiency management, the efficiency standard is developed by reliable data registered in domestic standby power reducing program. To find an efficiency indication for grade, correlation analysis is used and as a result, printing speed has the biggest correlation coefficient. By applying the efficiency indication for grade, the proposed certification standard is established in 1st to 5th level products and super-high-efficiency product (energy frontier) which is better than 1st to 5th level products. If these efficiency standards are chosen by government policies, it is expected to save 65 billion won reduction of energy cost per year.

RNSXI(real-name shooting X-ray of inspector) Settlement Realization applying PACS Database, In Digital Medical environment (PACS Database를 활용한 촬영실명제 정착화 실현)

  • Kang, Ji-Youn;Lee, Lae-Gon;Kang, Doo-Hee;Lee, Hwa-Sun;Hwang, Sun-Gwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.5-9
    • /
    • 2007
  • As developing the medical treatment image portion with the change of these times, PACS, which is able to digitalize image portion data, has a lot of data-based image data. Applying this PACS, we would like to settle down RNSXI(real-name shooting X -ray of inspector) system. We interviewed with P ACS's operators of university hospitals which is using PACS in Seoul about the present conditions whether using of RNSXI or not. And we inquired the RNSXI equipments, applying PACS database, and Interface conditions undertook to do in our hospital. All university hospitals in Seoul are set up the P ACS system. But no hospital use the RNSXI. In our hospital, we can check inspector' name or initials who exposure x-ray with the PACS Viewer by looking over equipments(CR, DR, US, MG, MR, CT) and Interface of the DICOM Header data. However, some equipments like RF and Angio can not check inspector' name or initials. Under the Film/System environment, RNSXI system has been used frequently like that inspector's signature or initial added to a patient data. Though the digital medical treatment was developed, RNSXI system was declined. It is necessary to using RNSXI system in order to improving radiologists' rights, even if it is not under the application of the medical treatment image laws. If RNSXI system use, radiologists should specialize in their major and the Repeat rate should be reduced. In environment of PACS, RNSXI system can be used by linking both the equipments and the Interface with a production enterprise of P ACS. Therefore RNSXI system applying the P ACS datebase should settle down in our medical system for being provided lots of data.

  • PDF

IMAGING IN RADIATION THERAPY

  • Kim Si-Yong;Suh Tae-Suk
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.327-342
    • /
    • 2006
  • Radiation therapy is an important part of cancer treatment in which cancer patients are treated using high-energy radiation such as x-rays, gamma rays, electrons, protons, and neutrons. Currently, about half of all cancer patients receive radiation treatment during their whole cancer care process. The goal of radiation therapy is to deliver the necessary radiation dose to cancer cells while minimizing dose to surrounding normal tissues. Success of radiation therapy highly relies on how accurately 1) identifies the target and 2) aim radiation beam to the target. Both tasks are strongly dependent of imaging technology and many imaging modalities have been applied for radiation therapy such as CT (Computed Tomography), MRI (Magnetic Resonant Image), and PET (Positron Emission Tomogaphy). Recently, many researchers have given significant amount of effort to develop and improve imaging techniques for radiation therapy to enhance the overall quality of patient care. For example, advances in medical imaging technology have initiated the development of the state of the art radiation therapy techniques such as intensity modulated radiation therapy (IMRT), gated radiation therapy, tomotherapy, and image guided radiation therapy (IGRT). Capability of determining the local tumor volume and location of the tumor has been significantly improved by applying single or multi-modality imaging fur static or dynamic target. The use of multi-modality imaging provides a more reliable tumor volume, eventually leading to a better definitive local control. Image registration technique is essential to fuse two different image modalities and has been In significant improvement. Imaging equipments and their common applications that are in active use and/or under development in radiation therapy are reviewed.

DICOM-based Tele-radiology System (DICOM-based 원격 진단 시스템)

  • Lee, S.H.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.71-73
    • /
    • 1995
  • In this paper, we reviewed the ACR-NEMA Digital Imaging and Communications in Medicine (DICOM) standard that was developed for medical imaging equipments interconnected on the standard networks. We also built a simple system that can transmit JPEG compressed DICOM file on network environment and display this medical image on remote-machine.

  • PDF