• Title/Summary/Keyword: Heat Insulation

Search Result 884, Processing Time 0.031 seconds

A Study on the Development of a Dry PFB Method with High Fire Resistance (고강도콘크리트 내화성능을 확보한 건식화 PFB 공법 개발에 관한 연구)

  • Kim, Woo-Jae;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.49-52
    • /
    • 2008
  • The present study was to develop a dry PFB method similar to the existing gypsum board construction method in order to apply the existing wet PFB method that uses fire-resistant adhesive. It was found that the existing wet method can produce concrete compressive strength of 80MPa and fire resistance of 3 hours with 30mm PF boards. The goal of development in this study was fire resistance of 3 hours through dry construction of 15mm fire-resistant boards. 1. Improved PF board was prepared by adding inorganic fiber to existing board and using aggregate with grain size of 3mm or less. Molding was done at temperature higher than that for existing PF board molding. While wet curing is used for existing PF boards, this study used dry curing in order to enhance heat insulation performance. 2. According to the results of fire resistance test, when the dry PF method was applied, the temperature of the main reinforcing bar was 116℃ in 15mm, 103.8℃ in 20mm, and 94℃ in 25mm, and these results satisfied the current standards for fire resistance control presented by the Ministry of Land, Transport and Maritime Affairs. When a 3-hour fire resistance test was performed and the external properties of the specimen were examined, the outermost gypsum board hardly remained and internal PF board maintained its form without thermal strain.

  • PDF

Fabrication and characterization of silicon-based microsensors for detecting offensive $CH_3SH\;and\; (CH_3)_3N$ gases

  • Lee, Kyu-Chung;Hur, Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.1
    • /
    • pp.38-42
    • /
    • 2008
  • Highly sensitive and mechanically stable gas sensors have been fabricated using the microfabrication and micromachining techniques. The sensing materials used to detect the offensive $CH_3SH$ and $(CH_3)_3N$ gases are 1 wt% Pd-doped $SnO_2$ and 6 wt% $Al_2O_3$-doped ZnO, respectively. The optimum operating temperatures of the devices are $250^{\circ}C$ and $350^{\circ}C$ for $CH_3SH$ and $(CH_3)_3N$, respectively and the corresponding heater power is, respectively, about 55mW and 85mW. Excellent thermal insulation is achieved by the use of a double-layer membrane: i.e. $0.2{\mu}m$-thick silicon nitride and $1.4{\mu}m$-thick phosphosilicate glass. The sensors are mechanically stable enough to endure the heat cycles between room temperature and $350^{\circ}C$, at least for 30 days.

A Study on the Insulation and Electrical Degradation Properties of Heat Resistance Epoxy Powder for Busduct (부스닥트용 내열성 에폭시 분체도료의 절연 및 열화 특성 연구)

  • Kang, Cheolhwa;Park, Ji-Koon;Park, Jong-Kyu;Ju, Hyun-Don;Kim, Hyun-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.662-668
    • /
    • 2013
  • Reported here are results of the mechanical and electrical properties of both of intact and thermally degraded epoxy-coated copper busducts that are made by fluidized bed process. To elucidate and compare the properties mentioned above, electrical breakdown by thermal and water aging, v-t characteristic, bending test, impact test and cross cut test are carried out. Although the performance of electrical and mechanical properties are gradually decreased in increasing the severe conditions such as temperature, aging time, and so forth, sample C has a better performance in both mechanical and electrical properties.

A Study on the Modeling of Vertical Spread Fire of Exterior Panel by Fire Dynamic Simulation (FDS) (FDS를 이용한 외장재의 수직 확산 화재의 모델링에 관한 연구)

  • Min, Seh-Hong;Yoon, Jung-En
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.77-85
    • /
    • 2009
  • Considering heat insulation and beautiful sight of construction, making use of exterior panels is increasing. Recently the exterior panels now are weak very much, and so in consequence of the weakness fire spreads rapidly. Compared with internal fire, external vertical fire spread rate goes rapidly and it is extensive in spread range, therefore it is dangerous very much. Accordingly, under present condition of poor standard of exterior panels, it is required to take measure to meet the appropriate situation. In this study, by making use of FDS(Fire Dynamic Simulation) program about external vertical fire of high rise building, fire behavior is searched by computer. It is important that realizing by computer fire modeling about external vertical fire must be included certainly in procedure of fire performance design in the future. In modeling program, FDS version 5 is available, and aluminium composite panel is applied in external panels. In this study, for realizing of actual fire condition, FDS is applied by details of fire scenarios considering influence of wind.

Thermal performance evaluation of Temperable Low-e glass window through Heating Energy consumption Analysis (난방에너지 사용량 분석을 통한 후강화 로이유리 창호의 단열성능 평가)

  • Jang, Cheol-Yong;Kim, Jeong-Gook;Ahn, Byung-Lip;Kim, Jun-Sup;Haan, Chan-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.200-205
    • /
    • 2012
  • In the high oil price age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating in large percent of whole building loads, and are regarding as the primary target of energy efficiency. In this study, in order to reduce heat loss of buildings, we investigate the thermal performance properties of Temperable Low-e glazing coated Ag membrane that has high electrical conductivity. The Temperable Low-e glazing windows has high insulation and shading properties, and it has strength that can supply various product which consumers want. In order to evaluate thermal performance of temperable windows, we install single low-e windows and double low-e windows in the experimental chamber and analysis the comparison heating energy consumption between single and double Low-e glazing windows. performance evaluation was conducted.

  • PDF

The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio (차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가)

  • Jang, Cheol-Yong;Han, Hye-Sim;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

of Renovation for Green Building of Public BuildingA Study on Adequacy (공공 건축물의 그린빌딩화를 위한 리노베이션수법의 타당성 연구)

  • Hyun, Gun-Chul;Kim, Tae-Il;Yang, Gun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.1-10
    • /
    • 2010
  • The aims of this study is to analyze that the double-skinned outer surface of building will be the effective measure to improve the use of space and save energy through the evaluation of the buildings renovation. In other words, it is significantly effective to increase the insulation of the outer surface where the most heat loss occurs; it is also energy-saving to convert the space created by pilotis in the southern and northern parts of the buildings into an double-skinned atrium. Research methods of this study are consisted with two steps, situation analysis and simulation analysis. IRISYS 1000 Series Imager was used for research of situation analysis and Visual DOE 4.0 was used for simulation analysis with the 1st Buildings of Jeju Special self-Governing Province. As results of simulation, it was proved that Double skin Method is more effective for green building than basic model. it was predicted to save 8.6% of energy by Double skin Method. Especially, in case of using of ventilation within double-skinned atrium, it was predicted that saving of energy was most effective than other method.

A Study on the Development of BIPV Module Equipped with Vacuum Glass for Improved Thermal Performance (단열성능 개선을 위한 진공유리가 부착된 BIPV Module 개발에 관한 연구)

  • Eom, Jae-Yong;Lee, Hyun-Soo;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.2
    • /
    • pp.44-52
    • /
    • 2014
  • The main purpose of this paper is to develop the new BIPV module equipped with vacuum glass. Beacuse BIPV module has a function of architectural materials, thermal and PV performance should be simultaneously evaluated. To improve the thermal performance of BIPV module, this study developed BIPV module equipped with a vacuum glass. Those BIPV module was tested with a variety of encapsulants. The results are as follows. When a vacuum glass is laminated with EVA or PVB, it was broken. The reason seems to be bending by unbalance of heat expansion with center and edge of vacuum glass. In case of lamination with resin, there is no breakage and no bending of vacuum glass. Because production was conducted in low pressure & low temperature conditions. And it was also found that vacuum glass does not interfere with the UV curing process.

The Air Leakage Characteristics and Airtightness Performance of a Newly Built Apartment (신축 공동주택의 누기특성 및 기밀성능 분석에 관한 연구)

  • Lee, Yun Gyu;Shin, Cheol Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.11
    • /
    • pp.606-611
    • /
    • 2013
  • In responding to the recent framework convention on climate change, and the rise of the need for energy efficient buildings, such as Zero Energy Buildings (ZEB), domestic insulation standards and energy conservation regulations are being reinforced, to prevent heat loss. Accordingly, the Ministry of Land, Infrastructure and Transport have made amendments in Chapter 21 "Enforcement regulations for building facilities standards etc.", and Chapter 22 "Energy conservation standard", to reflect these changes. To effectively implement these regulations, it is required to propose air-tightness test methods, and establish air-tightness standards, based on the air leakage characteristics of domestic apartment housings. This research has been done primarily to collect basic technical data, to provide guidance for the establishment of domestic air-tightness standards for new apartment housing, through studying air-tightness test methods, field measurement on air-tightness of new apartment housings, and air leakage characteristics of major developed countries.

Finite Element Analysis of Adiabatic Properties for the Wall System in Wood Frame House (유한요소법을 이용한 벽체의 단열 성능 분석)

  • Shim, Kug-Bo;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.48-57
    • /
    • 1995
  • 본 연구에서는 경골 목조 주택 (2${\times}$4 주택, 2${\times}$6 주택), 통나무 주택 및 콘크리트 주택(내단열, 중단열, 외단열) 벽체에 대하여 유한 요소 해석으로 단열 성능을 평가하였고, 표면 결로 현상을 분석하여 다음과 같은 결론을 얻었다. 1. 벽체의 단열 성능은 정량 골조 2${\times}$6를 사용한 주택이 가장 우수하였고, 경량 골조 2${\times}$4 주택, 통나무 주택, 콘크리트 주택의 순으로 감소하는 것으로 나타났다. 2. 콘크리트 벽체의 내단열, 중단열, 외단열의 벽체 구성법에 따른 단열 성능의 차이는 없었으며, 콘크리트 주택에서 단열재의 사용이 필수적이었다. 3. 내부 결로의 경우 콘크리트 벽체의 외단열이 가장 우수한 결로 예방성을 보였다. 이는 외부에 설치된 단열층이 외부의 낮은 온도를 차단해 벽체 전체의 온도를 높게 유지하기 때문이었다. 표면 결로는 모든 벽체에서 나타나지 않았지만, 실내 습도가 높아진다면 콘크리트 주택의 벽체에서 발생할 가능성이 가장 높았다. 본 연구는 벽체내의 단열 성능에 관하여만 분석을 하였고, 열전달 외에 축열성능 등에 관한 고려는 하지 않았으므로 추후에는 여러 가지 복합적인 열적 성능에 관한 연구가 수행되어야 하리라고 생각한다.

  • PDF