Abstract

In responding to the recent framework convention on climate change, and the rise of the need for energy efficient buildings, such as Zero Energy Buildings (ZEB), domestic insulation standards and energy conservation regulations are being reinforced, to prevent heat loss. Accordingly, the Ministry of Land, Infrastructure and Transport have made amendments in Chapter 21 "Enforcement regulations for building facilities standards etc.", and Chapter 22 "Energy conservation standard", to reflect these changes. To effectively implement these regulations, it is required to propose air-tightness test methods, and establish air-tightness standards, based on the air leakage characteristics of domestic apartment housings. This research has been done primarily to collect basic technical data, to provide guidance for the establishment of domestic air-tightness standards for new apartment housing, through studying air-tightness test methods, field measurement on air-tightness of new apartment housings, and air leakage characteristics of major developed countries.

Keywords

References

  1. Lee, Y., 1998, A study on prediction model of ventilation performance for multi-family housings using airflow analysis, Ph.D. thesis, Yonsei University.
  2. KICT, 2011, A research on standard of ventilation and air tightness performance in buildings.
  3. AIVC, 2011, Towards optimal airtightness performance, AIVC.

Cited by

  1. A Study on the Analysis of Airtightness Performance of Dilapidated Dwelling According to the Application of Windbreak vol.865, pp.1662-7482, 2017, https://doi.org/10.4028/www.scientific.net/AMM.865.200