• Title/Summary/Keyword: Frequency Response function

Search Result 1,051, Processing Time 0.027 seconds

Analysis of Dynamic Characteristics on Condenser for the Control of Air Conditioning Systems (공조기 제어를 위한 응축기의 동특성 해석)

  • Kim, J.D.;Yoon, J.I.;Higuchi, K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.386-396
    • /
    • 1996
  • The dynamic characteristics of a condenser are numerically studied for the control of air-conditioning systems. The important factors, such as the refrigerant flow rate and refrigerant temperature, air velocity and air temperature at the condenser inlet, are incorporated into the analysis. This study was focused on the analysis of dynamic responses by transfer function method in the condenser. Block diagrams were made through analytic transfer function, and dynamic responses are evaluated on Bode diagrams in the frequency response. These results may be used for determining an optimum design parameters in an actual component and total systems. Also, the mathematical models, frequency response and steady state response may be used to increase understanding, to obtain useful information for its commercialization, to evaluate the hardware and the optimum design parameters, the design control system and to determine the best controller setting for the refrigeration and air conditioning systems.

  • PDF

A Study on the Frequency Response Signals of a Servo Valve (서보밸브의 주파수 응답 신호에 관한 연구)

  • Yun, Hongsik;Kim, SungDong
    • Journal of Drive and Control
    • /
    • v.18 no.1
    • /
    • pp.17-23
    • /
    • 2021
  • The flow signal or spool position signal is used to determine the dynamic characteristics of directional control valves. Alternatively, the signal of spool position or flow can be replaced with the velocity of a low friction, low inertia actuator. In this study, the frequency response of the servo valve equipped with a spool position transducer is measured with a metering cylinder. The input signal, spool displacement, load pressure, and velocity of the metering cylinder are measured, and the theoretical results from the transfer function analysis are verified. The superposition rule for magnitude ratio and phase angle was found to be always applicable among any signal type, and it was found that the load pressure signal is not appropriate for use as the signal for measuring the frequency response of a servo valve. It was confirmed that the frequency response of a servo valve using metering cylinder was similar to the results from a spool displacement signal. The metering cylinder used for measuring the frequency response of a servo valve should be designed to have sufficiently greater bandwidth frequency than the bandwidth frequency of the servo valve.

Analysis of added resistance of a ship advancing in waves (파랑중에서 전진하는 선박의 부가저항 해석)

  • 이호영;곽영기
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.91-99
    • /
    • 1997
  • This paper presents theoretical formulations and numerical computations for predicting first-and second-order hydrodynamic force on a ship advvancing in waves. The theoretical formulation leads to linearized radiation and diffration problems solving the three-dimensional Green function integral equations over the mean wetted body surface. Green function representing a translating and pulsating source potantial for infinite water depth is used. In order to solve integral equations for three dimentional flows using Green function efficiently, the Hoff's method is adopted for numerical calculation of the Green function. Based on the first-order solution, the mean seconder-order forces and moments are obtained by directly integrating second-order pressure over the mean wetted body surface. The calculated items are carried out for analyzing the seakeeping characteristics of Series 60. The calculated items are hydrodynamic coefficients, wave exciting forces, frequency response functions and addd resistance in waves.

  • PDF

Estimation of Pump Induced Vibration Force Using Transfer Function (전달함수를 이용한 펌프(50Hp)의 진동가진력 산정)

  • 노병철
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.157-162
    • /
    • 1998
  • Dynamic loads may arise from rotating parte of pump if they are insufficiently balanced. The magnitude of pump induced vibrations varies according to the weight, eccentricity, and unbalanced mass of pump. This is a study to estimate the pump induced vibration in time and frequency domain by transfer function. The transfer function has real and imaginary information of signals, and response function has also real and imaginary information. So the vibration force can be obtained from the response and transfer function by complex calculation. The amplitudes and components of 50Hp pump vibration force are suggested.

  • PDF

Development of 3-ch. Vibration Generator S/W for Virtual Test (가상시험을 위한 소프트웨어 기반 3채널 가진기 개발)

  • Kim, Kwang-Suk
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.205-210
    • /
    • 2021
  • In this study, I studied how to generate input values to achieve the same value as the target value. The general procedures are explained to regenerate the excitation input, which is made by using the frequency response function between input-output. In this study, a mount model connected by a bushing was used as a numerical model. The response value for the excitation input was compared with the target value. The excitation input was corrected to obtain the same response as the target value. Through the iterative process, the reconstructed input value was obtained to have the same response as the test.

Updating of a Finite Element Model with a Damping Effect Using Frequency Response Functions (주파수응답함수를 이용한 감쇠가 있는 유한요소모형의 개선)

  • Lee, Geon-Myeong;Lee, Hyeong-Seok;Lee, Han-Hui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.5
    • /
    • pp.872-880
    • /
    • 2002
  • The finite element analysis is frequently used to predict dynamic responses of complex structures. Since the predicted responses often differ from experimentally measured ones, updating of the finite element models is performed to make the finite element results agree with the measured ones. Among several model updating methods, one is to use FRF(frequency response function) data without a modal analysis. This paper investigates characteristics of the model updating method in order to improve the method. The investigation is focused on how to obtain FRFs for unmeasured rotational displacements and how to consider damping. For the investigation simulated data and experimental data for a cantilever beam are used.

In-situ modal testing and parameter identification of active magnetic bearing system by magnetic force measurement and the use of directional frequency response functions (전자기력 측정과 방향성주파수 응답함수를 이용한 능동 자기베어링 시스템의 운전중 모드시험 및 매개변수 규명)

  • Ha, Young-Ho;Lee, Chong-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.7
    • /
    • pp.1156-1165
    • /
    • 1997
  • Complex modal testing is employed for the in-situ parameter identification of a four-axis active magnetic bearing system while the system is in operation. In the test, magnetic bearings are used as exciters as well as actuators for feedback control. The experimental results show that the directional frequency response function, which is properly defined in the complex domain, is a powerful tool for identification of bearing as well as modal parameters. It is also shown that the position and current stiffnesses can be accurately estimated using the relations between the measured forces, displacements, and currents.

A Structural Damage Identification Method Based on Spectral Element Model and Frequency Response Function

  • Lee, U-Sik;Min, Seung-Gyu;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.6
    • /
    • pp.559-565
    • /
    • 2003
  • A spectral element model-based structural damage identification method (SDIM) was derived in the previous study by using the damage-induced changes in frequency response functions. However the previous SDIM often provides poor damage identification results because the nonlinear effect of damage magnitude was not taken into account. Thus, this paper improves the previous SDIM by taking into account the nonlinear effect of damage magnitude. Accordingly an iterative solution method is used in this study to solve the nonlinear matrix equation for local damages distribution. The present SDIM is evaluated through the numerically simulated damage identification tests.

Identification of Structural Parameters from Frequency Response Functions (주파수 응답함수를 이용한 구조 파라메터 예측)

  • Kim, Kyu-Sik;Kang, Yeon-June
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.863-869
    • /
    • 2007
  • An improved method based on a normal frequency response function (FRF) is proposed to identify structural parameters such as mass, stiffness and damping matrices directly from the FRFs of a linear mechanical system. The method for estimating structural parameters directly from the measured FRFs of a structure is presented. This paper demonstrates that the characteristic matrices are extracted more accurately by using a weighted equation and eliminating the matrix inverse operation. The method is verified for a four degree-of-freedom lumped parameter system and an eight degree-of-freedom finite element beam. Experimental verification is also performed for a free-free steel beam whose size and physical properties are the same as those of the finite element beam. The results show that the structural parameters, especially the damping matrix, can be estimated more accurately by the proposed method.

  • PDF

Use of Higher Order Frequency Response Functions for Non-Linear Parameter Estimation (고차 주파수응답함수를 이용한 비선형 시스템의 매개변수 추정)

  • 이건명
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.40-45
    • /
    • 1994
  • 기계시스템의 비선형특성 해석을 위하여 여러가지 방법이 활용되고 있는데, 이들은 Nyquist 선도의 찌그러짐(distortion), Hilbert 변환, 복원력면(restoring force surface), NARMAX, 고차 주파수응답함수(higher order frequency response function), DPE(direct parameter estimation)를 이용한 방법등이다. 이들중 고차 FRF(frequency response function)는 그 개념이 선형시스템의 FRF와 유사하여 비선형시스템의 해석방법으로서 주목을 받고 있으나 아직은 고차 FRF의 특성에 대한 이론적 연구 단계이고, 고차 FRF로부터 비선형특성을 정량적으로 해석하는 연구는 거의 이루어지지 않고 있다. 다항식으로 표시되는 비선형성을 갖는 시스템이 정현파가진을 받을 때 그 응답의 가진주파수 성분은 가진력진폭과 고차 FRF의 무한급수로 나타낼 수 있다. 가진력의 진폭을 변화시켜가며 응답을 측정하고, 고차항을 무시하면 고차 FRF의 값을 근사적으로 구할 수 있다. 고차 FRF는 비선형 시스템의 매개변수의 식으로 나타낼 수 있으므로 이로부터 비선형 매개변수를 추정할 수 있다. 본 논문에서는 비선형강성과 비선형감쇠를 갖는 1자유도 시뮬레이션 시스템에 이 매개변수 추정법을 각각 적용함으로써 이 방법의 가능성을 고찰하였다.

  • PDF