• Title/Summary/Keyword: Energy linearity

Search Result 252, Processing Time 0.021 seconds

Design and Analysis of Fuzzy Control in a Variable Speed Refrigeration System

  • Hua, Li;Jeong, Seok-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.2
    • /
    • pp.61-69
    • /
    • 2007
  • This paper deals with fuzzy control with a feedforward compensator to progress both energy saving and coefficient of performance (COP) in a variable speed refrigeration system. Both the capacity and superheat are controlled simultaneously and independently in the system. By adopting the fuzzy theory, the controller design for the capacity and superheat is possible without depending on a dynamic model of the system. Moreover, the feedforward compensator of the superheat can reduce influence of the interfering loop between the capacity and superheat. Some experiments are conducted to design appropriate fuzzy controller by an iteration manner. The results show that the proposed fuzzy controller with the compensator can establish good control performances for the complicated refrigeration system in spite of its inherent strong non-linearity. Also, the fuzzy control performances were investigated by comparing to the model based PI control experimental results to evaluate transient behavior under the control.

Spectroscopic Properties of Gamma-ray Detector to Measure the Burnup of Spent Nuclear Fuel (사용후핵연료 연소도 측정을 위한 감마선 검출기의 분광특성 연구)

  • Hey Min Park;Tae Young Kim;Yang Soo Song;Un Jang Lee;Cheol Min Ham
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.119-125
    • /
    • 2023
  • Burnup of spent nuclear fuel should be determined accurately for the safety storage of spent nuclear fuel. In this study, a gamma detection system was developed as a part of basic research to measure the burnup of spent nuclear fuel, and its performance was evaluated using a calibration source. The prototype of the gamma detection system was based on a semiconductor sensor using a CZT (Cadmium Zinc Telluride). For quantitative evaluation, tests were conducted using 137Cs, 134Cs and 252Cf calibration source. In the performance evaluation, Its field applicability was verified by assessing the energy resolution, the detection linearity and the shielding attenuation according to the nuclide.

Design of an integrated multiple-single-channel analyzer

  • Jie Yang;Xiaofei Gu;Shuxiang Lu;Guoheng Zheng
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2557-2562
    • /
    • 2024
  • A type of integrated multiple-single-channel analyzer (IMSCA) is described. The IMSCA works with an input pulse of 2-20 pC, and it can be directly connected to a scintillation detector, which eliminates the need for a linear amplifier. It consists of 64 input ports, so 1-64 detectors can be set by users according to different requirements. Two energy regions for each input channel can be simultaneously analyzed. Another advantage of the IMSCA is that it integrates with a high-speed pulse signal acquisition card and transmits data to the computer through the network. The maximum pulse through-rate is 1.4 MHz, and linearity can reach 0.1%. This IMSCA has been successfully used in enrichment detecting of nuclear fuel rod.

A Study on the development and calibration method of a modular internal resistance meter to improve the safety of reusable batteries

  • Mi-Jin Choi;Sang-Bum Kim
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.228-235
    • /
    • 2024
  • Battery use is increasing worldwide to achieve carbon neutrality and improve energy efficiency, but batteries are a finite resource and their application is determined by capacity and specifications. Battery performance deteriorates as the number of uses increases. A certain level of battery performance degradation has become an issue in the field of reuse and recycling, and various studies are being conducted on reuse to solve power shortages. Waste batteries from electric vehicles are suitable for building ESS based on reusable batteries, and for stable use, technical skills are needed to accurately predict battery life and determine status information. Predicting battery life and determining status information are difficult due to non-linearity due to internal structure or chemical changes. In this paper, we manufactured a modular internal resistance measuring device and compared the measured values with Hioki equipment to minimize the error rate through a correction method. As a result of testing Hioki equipment and modular measuring instruments to ensure efficiency and safety based on reusable batteries, an accuracy of over 95% was confirmed.

Fabrication of Catalytic Conbustion type Sensor and its Measuring Characteristics (접촉 연소식 가스센서의 제조 및 계측특성)

  • Lee, D.S.;Han, S.D.;Myung, K.S.;Lee, S.H.;Son, Y.M.;Lee, J.D.
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.16-22
    • /
    • 1995
  • Catalytic combustion type gas sensor was fabricated by using ${\gamma}-Al_{2}O_{3}$, Pd catalyst and some binders for metane and propane detection. Using the gas sensor, digital gas meter was manufactured and tested for sensing performance. The fabricated sensor had power consumption of 700mW with applied voltage of dc 2V and the output voltage of the sensor was about 700mV for propane of 1,000ppm and 500mV for methane of 1,000ppm. In 10 cycle injection of the gases of 2,400ppm, The digital meter showed good sensitivity, linearity, and reproductivity with precision of ${\pm}25ppm({\pm}1%)$.

  • PDF

Comparison of Estimated and Measured Doses of Dual-energy Computed Tomography (Dual-energy 컴퓨터단층촬영에서 장비 제공선량과 측정선량 비교)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.405-411
    • /
    • 2018
  • We will provide basic data on the evaluation of patient dose in terms of DECT quality control by comparing the equipment-provided dose with the measured dose according to the configuration method of the X-ray generator by the manufacturer of the dual-energy CT unit. For computed tomography (CT) equipment, Discovery 750HD, Aquilion ONE GENESIS Edition, and Somatom Definition Flash were used. The $CTDI_{vol}$ value was measured by inserting the Unfors Xi ion chamber into a 32 cm PMMA acryl Phantom. The results of estimated $CTDI_{vol}$ DECT and measured $CTDI_{vol}$ showed that the dose difference between DECT 80 + 140 kVp of G company was at least 0.51% and -1.90% max, and measured $CTDI_{vol}$ was slightly lower (p<0.05). The difference of 80 + 140 kVp of S company was the minimum of 5.84% and the maximum of 7.52% (p<0.05). The measured $CTDI_{vol}$ was less than estimated $CTDI_{vol}$. The C company's 80 + 135 kVp showed a difference of at least 7.58% and a maximum of 13.58% (P<0.05), and all of measured $CTDI_{vol}$ was less. The linearity of exposure dose for all DECT equipment was very linearly reflected with $R^2$ being 0.97 or above, and the measured dose of the ionization chamber was less than the predicted dose of the monitor.

Measurements of Transient Mixing Concentrations between Solid Powder and Liquid Fuel (고체분말/액체연료의 과도혼합 농도 분포 측정)

  • Doh, Deoghee;Yum, Jooho;Cho, Gyeongrae;Min, Seongki;Kim, Myungho;Ryu, Gyongwon;Yoo, Namhyun
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.6
    • /
    • pp.678-687
    • /
    • 2012
  • Concentration fields of solid powder in a liquid fuel were quantitatively measured by a visualization technique. The measurement system consists of a camcoder and three LCD monitors. The solid powder (glass powder) were filled in a head tank which was installed over a main mixing tank ($D{\times}H$, $310{\times}370mm$). The main mixing tank was filled with JetA1 fuel oil. With a sudden opening of the upper tank by pressurized nitrogen gas with 1.9 bar, the solid powder were poured into the JetA1 oil. An impeller type agitator was being rotated in the mixing with 700 rpm for the enhancements of mixing. Uniform visualization for the mixing flow field was made by the light from the three LCD monitors, and the visualized images were captured by the camcoder. The color images captured by the camcoder The color information of the captured images was decoded into three principle colors R, G, and B to get quantitattive relations between the concentrations of the solid powder and the colors. To get better fitting for the strong non-linearity between the concentration and the color, a neural network which has strong fitting performances was used. Analyses on the transient mixing of the solid powders were quantitatively made.

Characteristics of Power Amplifier for Energy Efficient Broadcasting Services (에너지 효율적 차세대 방송망 구축을 위한 증폭기 특성과 신호 모델)

  • Han, Jae-Shin;Jeon, Sungho;Choi, Jeong-Min;Seo, Jong-Soo
    • Journal of Broadcast Engineering
    • /
    • v.18 no.6
    • /
    • pp.884-894
    • /
    • 2013
  • In this paper, we investigate the characteristics of power amplifiers and simplified memoryless non-linear power amplifier models for energy efficient communication system. First, we present the transfer function of GaAs FET (Gallium Arsenide Field Effect Transistor) that is widely used for high power amplifier. From those investigations, we introduce the instantaneous efficiencies and methods of amplification by assuming that the saturated current is constant, while perfect linearity is exploited under knee voltage. Then, we discuss four non-linear power amplifier models in a baseband signal processing. Finally, we explain the specified total power consumption model in a base station to achieve the resonable analysis for energy efficient communication.

Fabrication and NOx sensing Characteristics of $WO_{3}$ doped with $SnO_{2}$ and Pt Thick Film Devices ($SnO_{2}$과 Pt를 첨가한 $WO_{3}$후막센서의 제조 및 NOx감응 특성)

  • Lee, D.S.;Han, S.D.;Park, K.B.;Sim, K.S.;Lee, D.D.;Son, Y.M.
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.47-54
    • /
    • 1996
  • Highly sensitive $WO_{3}$ doped with $SnO_{2}$ and Pt thick-film sensors for NOx gas were fabricated. The sensors had a maximum sensitivity at operating temperature of $250^{\circ}C$, but the optimum operation temperature, considering recovery desorption time, was at $330^{\circ}C$. These sensors improved sensitivity, response and recovery time, selectivity and stability, as compared to $WO_{3}$ sensors. The good linearity of sensitivity as a function of the gas concentration exhibited the possibility to be used for concentration meter.

  • PDF

Feasibility study of CdZnTe and CdZnTeSe based high energy X-ray detector using linear accelerator

  • Beomjun Park;Juyoung Ko;Jangwon Byun;Byungdo Park ;Man-Jong Lee ;Jeongho Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2797-2801
    • /
    • 2023
  • CdZnTeSe (CZTS) has attracted attention for applications in X- and gamma-ray detectors owing to its improved properties compared to those of CdZnTe (CZT). In this study, we grew and processed single crystals of CZT and CZTS using the Bridgeman method to confirm the feasibility of using a dosimeter for high-energy X-rays in radiotherapy. We evaluated their linearity and precision using the coefficient of determination (R2) and relative standard deviation (RSD). CZTS showed sufficient RSD values lower than 1.5% of the standard for X-ray dosimetry, whereas CZT's RSD values increased dramatically under some conditions. CZTS exhibited an R2 value of 0.9968 at 500 V/cm, whereas CZT has an R2 value of 0.9373 under the same conditions. The X-ray response of CZTS maintains its pulse shape at various dose rates, and its properties are improved by adding selenium to the CdTe matrix to lower the defect density and sub-grain boundaries. Thus, we validated that CZTS shows a better response than CZT to high-energy X-rays used for radiotherapy. Further, the applicability of an onboard imager, a high-energy X-ray (>6 MV) image, is presented. The proposed methodology and results can guide future advances in X-ray dose detection.