• 제목/요약/키워드: Electrokinetic effect

검색결과 59건 처리시간 0.023초

Phenanthrene으로 오염된 Kaolinite에 Electrokinetic-Fenton 기법 적용시 묽은 산의 주입에 따른 효과

  • 김정환;김기년;한상재;김수삼
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.318-321
    • /
    • 2003
  • This study explored the feasibility of applying Electrokinetic-Fenton process(EK-Fenton process) to remediation of contaminant sorbed on the soil possessed low-permeability. The addition of 0.01 N H$_2$SO$_4$ in the anode reservoir for the $H_2O$$_2$stabilization improved the stabilization of $H_2O$$_2$and the treatment effect of phenanthrene across the entire soil specimen. The use of $H_2O$$_2$and dilute acid as anode purging solution is a promising method treating of HOCs in low-permeability subsurface environments.

  • PDF

계면활성제를 이용한 향상된 EK 정화 시 PAH의 제거

  • 김강호;한상재;김수삼
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.127-130
    • /
    • 2001
  • This paper presented to phenanthrene removal of electrokinetic(EK) remediation and enhanced EK remediation with bench scale test. The experiments were carried out on mixture soil with phenanthrene as the test compound. The EK remediation experiments were conducted under controlled voltage. Surfactant solution was constantly supplied at the anode reservoir with constant concentration. Results showed that phenanthrene was removed little in EK remediation. Surfactant helped phenanthrene moving and cumulated in cathode region. Moving effect was increased with surfactant concentration.

  • PDF

불포화토의 동전기 정화 특성 II : 수치 해석적 연구 (The Characteristics of Electrokinetic Remediation of Unsaturated Soil II : Numerical Analysis)

  • 김병일;한상재;김수삼
    • 대한토목학회논문집
    • /
    • 제26권1C호
    • /
    • pp.9-17
    • /
    • 2006
  • 불포화 자연토에서의 E/K 영향 인자별 정화 특성을 예측하기 위해 지배방정식을 확립하였고, 유한차분해석 기법의 적용을 위한 정식화를 수행하였다. 유한차분화된 지배방정식을 사용하여 HERO를 개발하였고, 개발된 프로그램을 기존 문헌에 제시된 결과에 대하여 검증하였다. 검증 완료된 HERO를 이용하여 불포화 자연토의 E/K 정화 특성을 예측한 결과, 전압경사 1V/cm의 조건에서 전류효율의 변화로 인하여 포화도에 따른 양극(兩極) 저수조 전해질의 pH에는 큰 변화가 없었다. 포화도가 증가할수록 산전선의 이동거리는 증가하는 것으로 나타났지만, 염기전선의 이동은 큰 변화를 보이지 않았다. 또한, 시료내 잔류 납 농도로부터 산정된 포화도별 제거율은 포화도가 증가할수록 감소하는 것으로 나타났지만, 포화도가 최적 함수비에 해당되는 약 83% 이상이 되면 큰 변화를 보이지 않는 것으로 예측되었다.

마이크로 PTV 기법을 이용한 미세채널 내부 계면의 electrokinetic 효과 해석 (Micro-PIV Measurements of interfacial electrokinetic effects in a microchannel)

  • 김국배;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.49-50
    • /
    • 2002
  • In micro-channels, the electro-viscous effect is caused by the electrical double layer on pressure-driven liquid flow. Velocity fields of flow inside micro-channels were measured using micro-PIV system for investigating the electro-viscous effect. De-ionized water and aqueous NaCl solutions with four different concentrations were used as working fluid in a PDMS micro-channel of $100{\mu}m$ width and $66{\mu}m$ height. The pressure gradient, dP/dx, was determined from the pre-determined input flow rate Q of syringe pump. The mean velocity $u_m$ used for calculating Reynolds number was obtained from the PIV velocity field data. These are used to plot the pressure gradient as a function of Reynolds numbers. The pressure gradient far lower concentration solution $(10^{-5}\;M)$ was higher than that for the higher concentration solution. The increase of flow resistance was about $30\%\;and\;37.5\%$ at Re=0.02 and 0.06, respectively.

  • PDF

방사성오염토양 제염을 위한 동전기세정장치 개발 (Development of Electrokinetic-Flushing Equipment for a Remediation of Soil Contaminated with Radionuclides)

  • 김계남;정윤호;이정준;문제권;정종헌;정운수
    • 방사성폐기물학회지
    • /
    • 제6권1호
    • /
    • pp.1-9
    • /
    • 2008
  • 투수성이 높은 토양에 대한 동전기세정 제염의 영향을 평가했다. 실험토양은 많은 모래를 함유하여 수리전도도가 높은 연구 원자로 주변부지로부터 채취했다. 세정용액의 방출속도는 제염시간 경과와 함께 감소했다. 시트릭산을 사용했을 때, 세정용액의 방출속도는 78.7 ml/day로 가장 빨랐다. 세정용액으로 초산을 사용하였을 때, 토양으로부터 코발트와 세슘의 제거효율은 가장 높은 값인 95.2%와 84.2%를 나타냈다. 동전기제염 시 발생된 토양 폐액부피는 토양세척제염시보다 1/20으로 감소했다. 반면에 동전기세정방법은 토양으로부터 코발트와 세슘 제거효율을 동전기방법 보다 각각 6%와 2%로 향상시켰다. 그러므로 동전기세정방법은 투수성이 높은 토양제염 시 좀 더 효과적이다.

  • PDF

Evaluation of Electrokinetic Remediation of Arsenic Contaminated Soils

  • Kim, Won-Seok;Kim, Soon-Oh;Kim, Kyoung-Woong
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.72-75
    • /
    • 2004
  • The potential of electrokinetic (EK) technology has been successfully demonstrated for the remediation of heavy metal contaminated fine-grained soils through laboratory scale and field application studies. Arsenic contamination in soil is a serious problem affecting both site use and groundwater quality. The EK technology was evaluated for the removal of arsenic from two soil samples: kaolinite clay artificially contaminated with arsenic and arsenic-bearing tailing soil taken from the Myungbong (MB) mining area. The effect of cathodic electrolyte on the process was investigated using three different types of electrolyte: deionized water (DIW), potassium phosphate (KH$_2$PO$_4$) and sodium hydroxide (NaOH). The result of experiments on the kaolinite clay shows that the potassium phosphate was most effective in extracting arsenic, probably resulting from anion exchange of arsenic species by phosphate. On the contrary, the sodium hydroxide seemed to be most efficient in removing arsenic from the tailing soil, and it is explained by the fact that sodium hydroxide increased the soil pH and accelerated ionic migration of arsenic species through increase in desorption and dissolution of arsenic species into pore water.

  • PDF

고전압 이용한 준설퇴적토 유효성 및 중금속 변화에 관한 연구 (Study of Effectiveness of using higher voltages in analysis of dredged sediments and heavy metal concentration)

  • 권기범;김상근;;유준;정하익
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1446-1451
    • /
    • 2008
  • The clay found in the river or in any waste water treatment plant usually have a very high content of water. A large amount of sediments hinder the navigation in river. In waste water treatment plant, there is requirement of settling the thick sludge. These problems are overcome by using rapid means of sedimentation and settling. This paper focus on how method of Electrokinetic sedimentation can be made faster. Sedimentation using Electrokinetic phenomenon has been discussed with varied voltage applied and effect and dose of coagulant in increasing the process. The experimental test has been carried out at water content that are generally present in the case of river and small canals carrying waste water. This paper also focus on different heavy metals concentration during the process and the power aspects of process. A series of experiment were done to support the proposed theory and how a bubble formation could hinder the purpose of experiment.

  • PDF

모세관 전기영동 분석에서 계면 동전기 주입에 미치는 공존 이온의 영향 (Effect of Coexisting Ions on Electrokinetic Injection in Capillary Electrophoresis Analysis)

  • 이광우;전지영;이광필
    • 분석과학
    • /
    • 제9권1호
    • /
    • pp.35-42
    • /
    • 1996
  • 원자력 발전소의 배관 부식 등의 방지를 위하여 초순수에 첨가되는 고순도 시약 중의 미량 음이온 성분올 모세관 전기영동법에 의하여 정량하는 분석법을 개발하였다. 전해질은 5mM 크롬산염(pH=8.0)을, 캐필러리는 내경이 50 또는 $75{\mu}m$인 석영 캐필러리 내부를 염화 삼메틸 실란으로 처리하여 사용하였다. 기타 기기 조건은 전압 20kV, 검출은 254nm에서 간접 자외흡수법을 사용하였고 주요 정량 성분은 $Cl^-$, $NO{_3}^-$, $SO{_4}^{2-}$, $N{_3}^-$, $PO{_4}^{3-}$등이며, 시료 주입은 시료 농도가 1ppm 이상일 때는 유체역학적 주입법으로, 1ppm 이하는 계면 동전기 주입법을 적용하였다. 특히 본 연구에서는 시료 주입시 공존 이온의 영향을 조사한 결과 유체역학적으로 시료를 주입할 때는 시료 내 공존하는 음이온의 영향이 크게 없었으나, 계면 동전기적인 시료 주입시에는 공존하는 이온량과 전기영동적 이동도에 따라 분석 이온의 신호 크기가 크게 변함을 확인하였으며, 각 분석 성분 주입량, 즉 신호 크기는 시료 용액의 저항에 비례하였다. 따라서, 분석 이온보다 과량의 공존 이온 존재하에 계면 동전기 주입법으로 분석할 경우 시료 용액과 표준 용액의 전기 전도도 차이를 보상할 수 있는 표준물 첨가법 또는 내부 표준물법 등의 적절한 방법을 반드시 사용해야 한다.

  • PDF

Pnenanthrene-오염토양의 동전기 생물학적복원에서 제거효율에 대한 황산염원의 영향 (Effect of Sulfate Source on Removal Efficiency in Electrokinetic Bioremediation of Phenanthrene-Contaminated Soil)

  • 김상준;박지연;이유진;양지원
    • KSBB Journal
    • /
    • 제21권6호
    • /
    • pp.428-432
    • /
    • 2006
  • 본 연구는 미생물이 오염물 분해를 위해 황산염이 필요한 동전기 생물학적복원에서 황산염원의 종류가 제거효율에 미치는 영향을 조사하였다. 대표오염물과 적용 미생물은 각각 phenanthrene과 Sphingomonas sp. 3Y였다. Magnesium sulfate를 이용했을 때 Mg이온은 음극에서 전기적으로 생성되는 수산화이온과 결합하여 전해질 pH를 크게 감소시키고 미생물활성을 저해하는 현상이 관찰되었다. 따라서 ammonium sulfate와 disodium sulfate를 이용했을 때 전해질 및 토양 pH가 중성영역으로 유지되었으며 미생물 활성도 높게 유지되었다. 하지만 전자의 경우 ammonium이 미생물의 오염물 분해를 지연시켜 제거효율이 오히려 magnesium sulfate의 21.8%보다 12.0%로 더 낮게 나타났으며, 반면 후자의 경우 27.2%로 제거효율이 증가된 것을 관찰할 수 있었다. 이와 같은 제거효율의 차이는 장기간의 처리에서는 더욱 두드러질 것으로 예상된다.

동전기 기술과 계면활성제를 이용한 clay에서의 Phenanthrene 제거

  • 박지연;이현호;조현정;양지원
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 창립총회 및 춘계학술발표회
    • /
    • pp.121-124
    • /
    • 2000
  • In-situ soil remediation using electrokinetics has been investigated and the attempts for the removal of hydrocarbons have been continued. In this study, the electrokinetic remediation using three different kinds of surfactnats was conducted for the removal of phenanthrene from clay The used surfactnats were APG, Brij30 and SDS. In the solubility test for phenanthrene, the experimental result was APG

  • PDF