Micro-PIV Measurements of interfacial electrokinetic effects in a microchannel

마이크로 PTV 기법을 이용한 미세채널 내부 계면의 electrokinetic 효과 해석

  • 김국배 (포항공과대학교 기계공학과 대학원) ;
  • 이상준 (포항공과대학교 기계공학과)
  • Published : 2002.11.01

Abstract

In micro-channels, the electro-viscous effect is caused by the electrical double layer on pressure-driven liquid flow. Velocity fields of flow inside micro-channels were measured using micro-PIV system for investigating the electro-viscous effect. De-ionized water and aqueous NaCl solutions with four different concentrations were used as working fluid in a PDMS micro-channel of $100{\mu}m$ width and $66{\mu}m$ height. The pressure gradient, dP/dx, was determined from the pre-determined input flow rate Q of syringe pump. The mean velocity $u_m$ used for calculating Reynolds number was obtained from the PIV velocity field data. These are used to plot the pressure gradient as a function of Reynolds numbers. The pressure gradient far lower concentration solution $(10^{-5}\;M)$ was higher than that for the higher concentration solution. The increase of flow resistance was about $30\%\;and\;37.5\%$ at Re=0.02 and 0.06, respectively.

Keywords