• 제목/요약/키워드: E-J power

검색결과 823건 처리시간 0.028초

이종매질에서의 이종전력케이블에 대한 은도 및 허용전류 계산 (The Ampacity of Dissimilar Power Cables Installed in Thermally Dissimilar Soil Materials)

  • 정성환;최상봉;남기영;류희석;이재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.399-401
    • /
    • 2005
  • When power cables cross regions with unfavorable thermal conditions, conductor temperatures higher than the design value can occur. This paper proposes the calculation algorithms of the permissible current-carrying capability of dissimilar power cables installed in thermally dissimilar soil materials.

  • PDF

Corrosion Properties of Duplex Stainless Steels - STS329LD and STS329J3L - for the Seawater Systems in Nuclear Power Plant

  • Chang, Hyun-Young;Park, Heung-Bae;Kim, Young-Sik;Ahn, Sang-Kon;Jang, Yoon-Young
    • Corrosion Science and Technology
    • /
    • 제10권2호
    • /
    • pp.60-64
    • /
    • 2011
  • Lean duplex stainless steels have been developed in Korea for the purpose of being used in the seawater systems of industry. There are also many important seawater systems in nuclear power plants. These systems supply seawater to cooling water condenser tubes, heat exchanger tubes, related pipes and chlorine injection systems. The flow velocity of some part of seawater systems in nuclear power plants is high and damages of components from corrosion are severe. The considered lean duplex stainless steels are STS329LD (20.3Cr-2.2Ni-1.4Mo) and STS329J3L (22.4Cr-5.7Ni-3Mo) and PRENs of them are 29.4 and 37.3 respectively. Physical, mechanical and micro-structural properties of them are evaluated, and electrochemical corrosion resistance is measured quantitatively in NaCl solution. Critical Pitting Temperatures (CPT)s are measured on these alloys and pit depths are evaluated using laser microscope. Long period field tests on these alloys are now being performed, and some results are going to be presented in the following study.

Design Consideration for Structure of 2500-4500V RC-GCT

  • Kim E. D.;Kim S. C.;Zhang C. L.;Kim N. K.;Bai J. B.;Li J. H.;Lu J. Q.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.36-38
    • /
    • 2001
  • A basic structure of 2500V-4500V reverse-conducting GCT (RC-GCT) is given in this paper. The punch-through type (PT) is adopted for narrow N-base with high resistivity so that the fast turn-off and low on-state voltage can be achieved. The photo mask design was made upon the both turn-off performance and solution of separation between GCT and integrated freewheeling diode (FWD) part. The turn-on and turn-off characteristics for reserve-conducting gate commutated thyristors (RC-GCTs) were investigated by ISE simulation. Additionally, the local carrier lifetime control by proton irradiation was adopted so as not only to obtain the reduction of turn-off losses of GCT but also to reach a soft reverse recovering characteristics of FWD

  • PDF

계통연계형 연료전지시스템 (The utility interactive fuel cell power system)

  • 손경종;송성근;이상훈;조수억;박성준;김광헌;문채주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.536-538
    • /
    • 2006
  • In this paper, an DC/DC converter system has been proposed, which is suitable for fuel cell based power generation systems. The proposed converter system has outstanding advantages over the conventional dc-dc converters with respect to high efficiency and high power density. The developed converter system has been experimentally tested with using DSP PWM controller so that the performance of the proposed converter could be effectively examined and the validity of the converter could be verified.

  • PDF

풍력발전단지가 도입되는 한전 실배전계통의 전압변동에 대한 분석 (A Study on Voltage Variation in KEPCO Distribution System by Introducing the Wind Power Plant)

  • 황진수;정원재;강성수;김병숙;강흥식;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.16-18
    • /
    • 2001
  • Recently, a study on operation in parallel between Distributed Generation(DG) unit and power distribution system has been growing interest in power distribution system. But, introducing the DG unit causes the problem due to rising the voltage variation on power distribution system. So, This paper presents the effect of introducing DG unit on distribution system. For this simulation, KEPCO distribution system is used.

  • PDF

66kV XLPE Cable용 조립형 접속함의 개발 (Development of Prefabricated Joint for 66kV Cross Linked Polyethylene Cable.)

  • 오응종;김기영;이준용;박정기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2123-2125
    • /
    • 1999
  • In recent the XLPE cable has been applied more widely because of its advantages, such as the low-cost and simple installation. For a prefabricated joint, its working time is short, its jointing procedures aγe simple, and its quality control is easy. Electrical performance targets of our developed 66kV cable accessories has been approved through the type test in accordance with IEC publication 840. This paper describes the developmental effort in terms of the design, structure and results of performance verification tests for 66kV XLPE cable system.

  • PDF

온라인 무정전전원장치의 병렬운전 제어기술 (Parallel Operation Control Technique of On-line UPS System)

  • 조준석;강병희;고재석;최규하;김진홍;정석언
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.501-505
    • /
    • 2001
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.

  • PDF

Fast Component Placement with Optimized Long-Stroke Passive Gravity Compensation Integrated in a Cylindrical/Tubular PM Actuator

  • Paulides, J.J.H.;Encica, L.;Meessen, K.J.;Lomonova, E.A.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.275-282
    • /
    • 2013
  • Applications such as vibration isolation, gravity compensation, pick-and-place machines, etc., would benefit from (long-stroke) cylindrical/tubular permanent magnet (PM) actuators with integrated passive gravity compensation to minimize the power consumption. As an example, in component placing (pick-and-place) machines on printed circuit boards, passive devices allow the powerless counteraction of translator including nozzles or tooling bits. In these applications, an increasing demand is arising for high-speed actuation with high precision and bandwidth capability mainly due to the placement head being at the foundation of the motion chain, hence, a large mass of this device will result in high force/power requirements for the driving mechanism (i.e. an H-bridge with three linear permanent magnet motors placed in an H-configuration). This paper investigates a tubular actuator topology combined with passive gravity compensation. These two functionalities are separately introduced, where the combination is verified using comprehensive three dimensional (3D) finite element analyses.

Simulation Tool을 이용한 어레이 설치 방법에 따른 태양광발전시스템 비교 (Comparison Photovoltaic Power System for Installation Method of the Array using Simulation Tool)

  • 임지혜;문은아;박정민;김대곤;조금배;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1396-1397
    • /
    • 2011
  • The world has problem of petrifaction energy exhaustion and environment pollution. We are looking up various solution plans regarding this problem. Solar power is one of the solution to solve the energy shortage problem. But solar power is affected by insolation. So we study tracking solar power system for the generation of electricity more. In this paper, we compared fixed solar power system with horizontal and vertical tracking solar power system. Two method were on he Maximum Power Point(MPP) using Solar pro.

  • PDF