• Title/Summary/Keyword: E test

Search Result 8,680, Processing Time 0.049 seconds

Evaluation of Dynamic Properties of Trackbed Foundation Soil Using Mid-size Resonant Column Test

  • Lim, Yujin;Nguyen, Tien Hue;Lee, Seong Hyeok;Lee, Jin-Wook
    • International Journal of Railway
    • /
    • v.6 no.3
    • /
    • pp.112-119
    • /
    • 2013
  • A mid-size RC test apparatus (MRCA) equipped with a program is developed that can test samples up to D=10 cm diameter and H=20 cm height which are larger than usual samples used in practice. Using the developed RC test apparatus, two types of crushed trackbed foundation materials were tested in order to get the shear modulus reduction curves of the materials with changing of shear strain levels. For comparison purpose, large repetitive triaxial compression tests (LRT) with samples of height H=60cm and diameter D=30 cm were performed also. Resilient modulus obtained from the LRT was converted to shear modulus by considering elastic theory and strain level conversion and were compared to shear modulus values from the MRCA. It is found from this study that the MRCA can be used to test the trackbed foundation materials properly. It is found also that strain levels of $E_{v2}$ mostly used in the field should be verified considering the shear modulus reduction curves and proper values of $E_{v2}$ of trackbed foundation must be used considering the strain level verified.

DETERMINATION OF FRACTURE TOUGHNESS BY UNIAXIAL TENSILE TEST

  • Oh, Hung-Kuk
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 1994.05a
    • /
    • pp.2-7
    • /
    • 1994
  • The dynamic fatigue life equation is applied to uniaxial tensile test. The resultant equations far the surface energy and fracture toughness are calculated with the data from the tensile test and compared with the ones from ASTM E399 test. During the crack propagation under model loading, the material of the crack tip undergoes the process of the elastic-plastic deformation in the uniaxial tensile test. The surface energy per unit area is proportional to the ratio of plastic and elastic elongations. The calculated fracture toughness of the metals are very well coincident to the ASTM E399's test results.

  • PDF

Analyse Perceptive de Structures Prosodiques de la Parole chez L'enfant entre 7 et 34 Mois (7-34개월 아동 언어의 PROSODIE 구조에 대한 지각적 분석)

  • Bae, Jung Sook
    • Korean Journal of Child Studies
    • /
    • v.12 no.2
    • /
    • pp.146-153
    • /
    • 1991
  • Cette ${\acute{e}}tude$ a pour but d'analyse perceptive de la prosodie au cours de l'apprentissage du langage chez l'enfant de 7 $\acute{a}$ 34 mois. C'est $bas{\acute{e}}$ sur deux tests auditifs : $Pr{\acute{e}}test$ auditif et test auditif approfondi, Cet dernier porte sur 158 $s{\acute{e}}quences$ $diff{\acute{e}}rentes$. Nous avons ainsi ${\acute{e}}tabli$ rapports possibles entre structures prosodiques et ${\acute{e}}tapes$ de l'acquisition du langage. Nous $d{\acute{e}}gagons$ en conclusion que l'acquisition prosodique s'est $achev{\acute{e}}e$ plus $t{\hat{o}}t$ que les autres ${\acute{e}}l{\acute{e}}ments$ linguistiques.

  • PDF

Laboratory Tests for the Applicability of Various Testing Devices for Measuring Degree of Compaction (여러가지 다짐 평가장비의 적용성을 위한 실내시험)

  • Yoo, Wan-Kyu;Lim, Nam-Gyu;Kim, Byoung-Il;Kim, Ju-Hyong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1178-1187
    • /
    • 2008
  • Quality assurance for embankment compaction is one of very important procedures to guarantee high quality construction. However, only sand replacement method (KS F2312) and static plate load test (KS F2310) which are conventional and tiresome methods are used to evaluate degree of compaction at construction fields. Recently, new types of devices such as the geogauge and the light falling weight deflectometer (LFWD), the soil impact hammer (CASPFOL) and dynamic cone penetration test etc. which are able to substitute for the conventional methods are begun to use to evaluate soil stiffness. In this study, a laboratory model test was performed to evaluate correlations among test results obtained from the new devices and to assess the potential use of them. All test results have correlations with relative density and water content. Especially, the coefficients of correlation between $E_G$ from the geogauge and $K_{30'}$ from the soil impact hammer and between $E_G$ from the geogauge and $E_{LFWD}$ from LFWD are more than 0.7 but those between the results from DCP and others are less than those between $E_{G{\cdot}}$ and $K_{30'}$ and $E_G$ and $E_{LFWD}$.

  • PDF

A study of the Development of Ship Integrated Combat Capability Operational Test and Evaluation using Missile Live-Fire and Reaction Time Analysis (유도탄 실사격 및 반응시간 분석보고서를 활용한 함정 통합전투성능 운용시험평가 발전방안 제시)

  • Kim, Byungjun;Kang, Jeongseok;Hur, Jangwan;Ko, Jangsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.259-266
    • /
    • 2022
  • This study aims to introduce missile live-fire during the ship operational test and evaluation(T&E) as a means of verifying the integrated combat capability(ICC) of various systems installed on naval ships. The research method identified domestic and foreign T&E systems and cases, and reports related to ICC, which were written during the ship's design stage. As a result of research, Republic of Korea is not conducting the missile live-fire at the ship T&E stage due to the lack of relevant systems, while the U.S. is conducting it based on the mission-based T&E and the end-to-end test system. As a way to improve within the current domestic ship acquisition systems, the reaction time analysis, a quantitative analysis result of ICC calculated at the ship basic design stage, was proposed to be verified by missile live-fire during ship operational T&E.

A Study on Electromagnetic Environmental Effects(E3) Test and Evaluation of Fighter Equipped with ELINT Pod (ELINT 포드를 장착한 전투기의 전자기 환경 영향(E3) 시험평가에 관한 연구)

  • Kim, In-Seon;Park, Young-Ju;Choi, Dae-Kyu;Kim, Jang-Pyo;Lee, Byeong-Nam
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.288-297
    • /
    • 2012
  • This paper describes the verification test on Electromagnetic Environmental Effects(E3), which conducted on ground as a final step to confirm the normal operation of ELINT pod and Safety-of-Flight of KF-16C/D mounted with ELINT pod prior to the initial flight. Based on MIL-STD-464A, indispensable 7 requirements among 14 detailed requirements total were carried out in the test. Considering the Safety-of-Flight(SOF), we invest a great deal of time and effort on Hazards of Electromagnetic Radiation to Ordnance(HERO) and Intra-system EMC test. E3 test and evaluation were performed on 62 equipments of KF-16C/D, respectively. As a result, we verify that KF-16C/D mounted with ELINT pod(hereafter "system") are electromagnetically compatible among all subsystems and equipment within the system and with environments caused by electromagnetic effects external to the system.

The Development and Evaluation of an e-Learning Program for Novice Nurses before Beginning to Work in a Hospital Using KMS(Knowledge Management System) (지식경영 시스템을 활용한 신규간호사 e-Learning 프로그램 개발 및 평가)

  • Song, Young-Shin
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.13 no.1
    • /
    • pp.82-89
    • /
    • 2007
  • Purpose: The purpose of this study was to develop and evaluate an e-Learning Program designed to enhance novice nurses's performance ability Method: The e-Learning program was designed for novice nurses before beginning to work in a hospital using a KMS(Knowledge Management System). This study was carried out from February 2006 to April 2007. The program had progressive steps including design, pilot test & modification, contents development, program application and evaluation. After the program design and pilot testing, the learner's satisfaction was analyzed. Result: The program site is http://kms.emc.ac.kr titled, 'Cyber Education Center'. The sixteen part course has been developed as follows: blood sugar test, skin test, insulin test 1, insulin test 2, blood culture, blood sampling, heat therapy, cold therapy, glycerin enema, preparation of operation, oxygen therapy, suction technique, transfusion, foley catheterization and aseptic technique. The overall learner's satisfaction score was 4.08 out of 5 points. Conclusion: E-Learning could be useful for education and nursing work. This method may be effective for clinical nurses.

  • PDF

Development of an Examination System for a e-Learning Quality Manager's Certificate (이러닝 품질관리사의 자격 검정 체제 개발)

  • Ryu, Jin-Sun;Moon, Dae-Young;Lee, Kyung-Soon;Kim, Hee-Pil
    • Journal of Engineering Education Research
    • /
    • v.16 no.1
    • /
    • pp.35-44
    • /
    • 2013
  • The purpose of this study is to develop an examination system for an e-learning quality manager's certificate which is composed of subjects, criteria, method of examination. The task model of e-learning quality manager was modify and task/knowledge/skill matrix was developed to design the examination system through conferences of DACUM committee and an advisory committee. And a survey was carry out to analyze validity of contents of the examination system. The major findings were as the follow: First, occupational specification, job specification, task specification and task/knowledge/skill matrix were developed. Second, examination subjects were developed based on task/knowledge/skill matrix, which were "Basis of e-Learning and plan of service", "Expulsion and management of e-learning infrastructure", "Development of e-learning contents", "Operation and evaluation of e-learning service". Third, the criteria and methods of examination for an e-learning quality manager's certificate were developed, which is composed of test type, the sum of test items, test time and acceptable standards.

Comparison and Analysis of Field Hydraulic Tests to Evaluate Hydraulic Characteristics in Deep Granite Rockmass (심부 화강암반의 수리특성 평가를 위한 현장수리시험 비교 및 해석 연구)

  • Dae-Sung Cheon;Heejun Suk;Seong Kon Lee;Tae-Hee Kim;Ki Seog Kim;Seong-Chun Jun;SeongHo Bae
    • Tunnel and Underground Space
    • /
    • v.34 no.4
    • /
    • pp.393-412
    • /
    • 2024
  • In selecting a disposal site for high-level radioactive waste, the hydrogeological research of the site is very important, and the hydraulic conductivity and the storage coefficient are key parameters. In this study, the hydraulic conductivity obtained by two different types of field hydraulic test equipment and methods was compared and analyzed for the deep granite rockmass in the Wonju area to understand the hydraulic characteristics of the deep granite rockmass. One was to perform the lugeon test, constant pressure injection test, and slug test at a maximum depth of 602.0 m by using the auto pressure/flow injection system, and the calculated hydraulic conductivity ranged from 1.26E-9 to 4.16E-8 m/s. In the overall depth, the maximum and minimum differences of the hydraulic conductivity were found to be about 33 times, and in the same test section, the difference by test method or analysis method was 1.13 to 8.25 times. In the other, the hydraulic conductivity calculated by performing a constant pressure injection test and a pulse test at a maximum depth of 705.1 m using the deep borehole hydraulic testing system was found to be 1.60E-10 to 2.05E-8 m/s, and the maximum and minimum differences were found to be about 130 times. In the constant pressure injection test, the difference depending on the analysis method was found to be 1.02 to 2.8 times. The hydraulic conductivity calculated by the two test equipment and methods generally showed similar ranges as E-9 and E-8 m/s, and no clear trend was observed according to depth. It was found that the granite rockmass in the Wonju area where the field hydraulic test was conducted showed low or very low rockmass permeability, and although there are differences in the range of hydraulic conductivity and the depth of application that can be measured depending on the applied test equipment and test method, it is generally believed that reliable results were presented.