DOI QR코드

DOI QR Code

A Study on Electromagnetic Environmental Effects(E3) Test and Evaluation of Fighter Equipped with ELINT Pod

ELINT 포드를 장착한 전투기의 전자기 환경 영향(E3) 시험평가에 관한 연구

  • Received : 2012.02.01
  • Accepted : 2012.05.04
  • Published : 2012.06.05

Abstract

This paper describes the verification test on Electromagnetic Environmental Effects(E3), which conducted on ground as a final step to confirm the normal operation of ELINT pod and Safety-of-Flight of KF-16C/D mounted with ELINT pod prior to the initial flight. Based on MIL-STD-464A, indispensable 7 requirements among 14 detailed requirements total were carried out in the test. Considering the Safety-of-Flight(SOF), we invest a great deal of time and effort on Hazards of Electromagnetic Radiation to Ordnance(HERO) and Intra-system EMC test. E3 test and evaluation were performed on 62 equipments of KF-16C/D, respectively. As a result, we verify that KF-16C/D mounted with ELINT pod(hereafter "system") are electromagnetically compatible among all subsystems and equipment within the system and with environments caused by electromagnetic effects external to the system.

Keywords

References

  1. MIL-STD-461E, Requirements for the Control of Electromagnetic Interface Characteristics of Subsystems and Equipment, Aug. 1999.
  2. MIL-STD-464A, Electromagnetic Environment Effects Requirements for Systems, Dec. 2002.
  3. 홍재영 외 2인, XKO-1 EMI/EMC 인증보고서, MADC-501-031215, 국방과학연구소 보고서, 2003. 12.
  4. 강설묵 외 2인, 철매-II 유도탄 전자파시험 결과보고서, ADDR-516-110019, 국방과학연구소 보고서, 2011. 1.
  5. 이진호 외 3인, MUAV 전자기환경 요구조건(탐색 개발), ADDR-509-091912, 국방과학연구소 보고서, 2009. 12.
  6. 박연수, 건설학도를 위한 재료역학, 구미서관, 2011. 2.
  7. DOD Instruction 6055.11, Protection of DOD Personnel from Exposure to Radiofrequency Radiation, Feb. 21, 1995.
  8. 신승재, "HERO 시험평가 기법 연구", 한국군사과학기술학회지 제10권 제2호, pp. 76-83 1997. 6.
  9. 조재호, 중거리 GPS 유도킷트 체계개발 F-5/F-16 Intra-system EMC 시험결과, ADDR -501-101615, 국방과학연구소 보고서, 2009. 12.
  10. 권종광, 조재호, 저속통제기 Intra-system EMC 시험결과, MADC-501-020280, 국방과학연구소 보고서, 2002. 3.