• 제목/요약/키워드: Detector Type

검색결과 591건 처리시간 0.022초

반응시간지수(Response Time Index)를 이용한 국내 화재감지기 등급분류에 관한 연구 (A Study on the Classification of Domestic Fire Detector using Response Time Index)

  • 홍성호;김동석;최기옥
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.46-51
    • /
    • 2017
  • This paper presents classification of domestic fire detector using response time index. Response time is measured using fire detector distributed in Korea, and the response time index is estimated. Plunge test prescribed by FM is conducted to measure response time of fire detector. The detector used to test is fixed temperature type(thermistor and bimetal type) and rate of rise temperature type(thermistor and pneumatic type). The nominal operation temperature of fixed temperature type detector is $70^{\circ}C$ and rate of rise temperature is $15^{\circ}C/min$. The fixed temperature type is measured 7 products, and the rate of rise temperature type is measured 5 products. The results show that in case of fixed temperature type(thermistor) is classified "Quick" or "Standard" and fixed temperature type(bimetal) is not classified. The rate of rise temperature type(thermistor) is classified "Fast" or "Ultra Fast" and the rate of rise temperature type(pneumatic) is classified "Very Fast" or "Ultra Fast". The pneumatic type shows more fast response than thermistor type. Also these results indicate the fixed temperature type(bimetal) is not suitable for early stage fire detection.

다가구 주택의 매트리스 화재 시 차동식 스포트형 감지기의 온도상승 및 동작시간 분석 (Analysis of Temperature Rise and Operation Time of Differential Spot Type Detector in Case of Mattress Fire in Multi-family House)

  • 김서영;공하성
    • 대한안전경영과학회지
    • /
    • 제23권3호
    • /
    • pp.97-102
    • /
    • 2021
  • This study developed a scenario to understand the reaction rate and operational time according to RTI value of rate of rise detector in each type in case of fire mattress. In the results of analyzing the reaction rate and operational time of detector in each scenario, in case when installing a single detector, the elevated temperature per minute was raised to 8℃/min ~ 9℃/min. In case when installing two detectors, it was raised to 9℃/min ~ 10℃/min. In case when installing three detectors, it was raised to 10℃/min. The horizontal distance between detector and mattress was 1.8m~2.5m. Whenever the number of detectors was increased, the horizontal distance was decreased. The operational time of detector was within maximum 540 seconds and minimum 420 seconds. As the research tasks in the future, there should be the researches on the effects of reaction rate of detector on the evacuation in case of fire through the result value of RSET by setting up the latency until the detector operates, and the researches on the safety by understanding if the operational time of detector is suitable for the evaluation standard of performance-centered design.

재래식 화재감지기와 P형 수신기에 대한 화재위치검출 및 신뢰성 개선 (Detection of Fire Location And Reliability Improvement of the Conventional Fire Detector and P-type Receiver)

  • 지승욱;김시국;양승현;이재진;김필영;이춘하
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.39-44
    • /
    • 2011
  • Automatic fire alarm system is set up to automatically detect fire on buildings. Because of economic reasons, P-type receiver and a conventional type fire detector is normally used for automatic fire alarm system in Korea. Because early detection of fire is regarded as important, the need of finding technique of fire location increases. This paper is studied a method to improve a reliability and add a function of fire location detection on a conventional type fire detector and P-type receiver. Fire location is detected by a method that controller attached on the receiver and the detector is read with a time lag. A reliability of fire detection alarm system is improved with a method that false fire alarm is able to decrease using two different principle detector together. This paper is studied for basic data of improvement of low-cost addressable automatic fire alarm system.

주택 실물화재실험에 의한 화재감지기 응답특성에 관한 연구 (A Study on the Response Characteristics of Fire Detector by Full-scale Experiment of Fire Phenomena in the Row House)

  • 사공성호;김시국;이춘하;정종진
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.67-72
    • /
    • 2009
  • 본 논문은 주택 실물화재실험에 의한 화재감지기 응답특성에 관한 연구로서 철거가 예정된 연립주택을 화재실험대상으로 선정하여 현재 가장 많이 사용되고 있는 감지기 종류인 열감지기(차동식, 정온식, 아날로그식)와 연기감지기(광전식, 아날로그식, 단독경보형)를 주택내부에 설치여 화재감지기의 응답특성을 분석하고, 추가적으로 건물내부로의 화염전파 및 화재확대를 관찰하기 위해 열전대를 설치하여 온도변화를 측정하였다. 실험결과 주택에서 효과적인 화재감지시스템을 구축하기 위해서는 연기감지기가 열감지기보다 주택용 감지기로 적합한 것으로 나타났다.

열 감지기의 응답특성에 관한 시험연구 (Experiment study on the Responsiveness of Spot- Type Heat Detector)

  • 이복영
    • 방재기술
    • /
    • 통권19호
    • /
    • pp.9-16
    • /
    • 1995
  • The spot-type heat detector is a main component of the automatic fire alarm system intended to signal when heat energy is produced in protected area. The most of protected area in our country is installed spot-type heat detector. On this study, the responsiveness to the change of environmental temp. of spot-type heat detec-tor were obtained and analyzed under specified temp., velocity in accordance with the KOFEIS stan-dard. The experiment was carried under the condition with the change of environmental temp. Concluion of this study is as follows : 1. It was confirmed that the responsiveness of rate-of rise heat detector is sensitive to temp. below 10 degrees above zero. The malfunction appeared at 40 degrees above zero and intended performance is disqualified at 50 degrees above zero. 2. The intended performance of fixed-temp. detector which is maintained for the change of envi-ronmental temp. But the responsiveneness is confirmed instability for the change of environmental temp.

  • PDF

화원에 따른 광전식 연기감지기 반응시간 분석 (Analysis of the Response Time of a Photoelectric Spot-Type Smoke Detector Depending on the Type of Fires)

  • 지승욱
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.89-94
    • /
    • 2013
  • The fire testing performed for smoke detector model approval in Korea tests only one kind of fire smoke. A photoelectric spot-type smoke detector using Mie scattering is affected by the wavelength of light beam and the particle diameter. According to UL (Underwriters Laboratories Inc.) 268 standard, this paper analyze the characteristic of the response for a photoelectric spot-type smoke detector on sale in Korea using various fire smokes. Probability that the response time is included in non-defective range is 100% in paper fire, 90% in wood fire and 75% in flammable liquid fire, 90% in wood fire and 75% in flammable liquid fire. According to the estimation for population mean of the response time choosing a confidence level of 99%, a maximum of 19% for wood fire and that of 38% for flammable liquid fire are defective. As the result of analysis of smoke particle, this paper is found that these results are caused by the smoke particles are wide variations in size or have very black.

광전식연기감지기 현장점검기기의 문제점에 관한 연구 (A Study on the Problem of Tester for the Field Inspection of the Photoelectric Smoke Detector)

  • 김시국;육현대;양승현;지승욱;이춘하
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.137-144
    • /
    • 2009
  • 본 논문은 광전식연기감지기 현장점검기기의 문제점에 관한 연구로서 현재 소방점검 시 광전식연기감지기의 성능확인을 위해 사용되는 A Type(향), B Type(디메틸실리콘오일), C Type(탄화수소혼합물)의 점검기기들을 실험대상으로 선정하고, 현장점검기기의 문제점을 도출하고자 신뢰성확인실험 및 성능확인실험, 연기시료에 따른 감지기 성능변화 실험을 실시하였다. 실험결과 소방점검 시 현장점검기기를 이용한 감도실험은 연기농도조건 및 풍속조건, 연기시료의 문제점을 확인할 수 있었으며, 결과적으로 현재 소방점검시 사용되는 광전식연기감지기 현장점검기기의 신뢰성에 문제가 있는 것을 확인할 수 있었다.

차동식스포트형열감지기 현장점검용 표준화기기 개발에 관한 연구 (A Study on the Development of Standardization Tester for the Field Inspection of the Rate of Rise Spot Type Heat Detector)

  • 김시국;육현대;양승현;지승욱;이춘하
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.85-92
    • /
    • 2009
  • 본 논문은 차동식스포트형열감지기 현장점검용 표준화기기 개발에 관한 연구이다. 현재 소방점검 시 차동식스포트형열감지기의 성능확인을 위해 사용되는 점검기기(4 Type)들을 실험대상으로 선정하여 문제점을 찾고, 도출된 문제점을 바탕으로 차동식스포트형열감지기 형식승인 시 감도시험기준과 동일한 온도조건인 실온보다 $30^{\circ}C$ 높은 온도로 자동설정 할 수 있고 설정된 온도를 계속 유지할 수 있는 기능과 풍속 조건인 풍속 85cm/s를 유지할 수 있는 차동식스포트형열감지기 현장점검용 표준화기기의 회로를 설계하고 시제품을 제작하였다. 개발된 시제품의 성능확인 결과 차동식스포트형열감지기의 형식승인시험 시 감도시험조건과 동일한 성능이 나타나는 것을 확인하였다.

랙크식 물류창고 조기 화재감지를 위한 최적 화재감지기 설치방법에 관한 실험연구 (An Experimental Study on the Optimum Installation of Fire Detector for Early Stage Fire Detecting in Rack-Type Warehouses)

  • 최기옥;김동석;홍성호
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.38-45
    • /
    • 2017
  • This paper is an experimental study to find an optimal detection method for detecting fire early in a rack-type warehouse stored with goods. In this study, we constructed rack-type structure with the fourth floor of 13.5 m high and conducted fire experiments which were to measure flow of heat/smoke in rack-type structure and response time of fire detectors. The detectors used at experiments were fixed temperature type detectors, rate of rise detectors, photoelectric smoke detectors, air sampling smoke detectors and flame detectors. The used ignition sources are n-heptane fire for response of heat detection and cotton fire for response of smoke detection. The fixed temperature type detectors, rate of rise detectors and photoelectric detectors were installed to every rack level respectively. The results show that the rate of rise detector should be installed every 2 levels and photoelectric smoke detector should be installed every 4 levels for the early stage fire detection. Air sampling smoke detectors can detect fire early in response to control of sensitivity, but there is a problem in false alarm. The fixed temperature detector is not suitable for early stage fire detection in warehouse and flame detector not worked if flame is not visible, so it need to install combination with other detector.

압력 센서를 이용한 씽글 헤드라인 타입의 캔 에어 리크 검출씨스템 개발 (Development Can Air Leak Detector System For Single Compression Head-Line Type Using Pressure Sensor)

  • 이종운
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.506-507
    • /
    • 1992
  • When it comes to the 'Leak Detector System' generally, our country has a large income 'Rotary Type Leak Detector' of foreign goods. The completed development of the 'Line Type Leak-Detector' system was produced to check Whether the containers for small and large on the filling line are auto defective. This system is applied to the filling package Processing during the production and contributed to inproving competiveness of domestic containers manufactures of all society of Industry. Also, high precision and realiablity, very compact size, low cost and Easy set-up etc. by checking the experimental data directly plan, Design and making for '1 Compression Head Control Leak Detector System'. This flexcible system can be equipped with multiple Compression heads depending on the requested prodution test rate and test precision.

  • PDF