A Study on the Classification of Domestic Fire Detector using Response Time Index (반응시간지수(Response Time Index)를 이용한 국내 화재감지기 등급분류에 관한 연구)

  • Hong, Sung Ho;Kim, Dong Suck;Choi, Ki Ok
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.46-51
    • /
    • 2017
  • This paper presents classification of domestic fire detector using response time index. Response time is measured using fire detector distributed in Korea, and the response time index is estimated. Plunge test prescribed by FM is conducted to measure response time of fire detector. The detector used to test is fixed temperature type(thermistor and bimetal type) and rate of rise temperature type(thermistor and pneumatic type). The nominal operation temperature of fixed temperature type detector is $70^{\circ}C$ and rate of rise temperature is $15^{\circ}C/min$. The fixed temperature type is measured 7 products, and the rate of rise temperature type is measured 5 products. The results show that in case of fixed temperature type(thermistor) is classified "Quick" or "Standard" and fixed temperature type(bimetal) is not classified. The rate of rise temperature type(thermistor) is classified "Fast" or "Ultra Fast" and the rate of rise temperature type(pneumatic) is classified "Very Fast" or "Ultra Fast". The pneumatic type shows more fast response than thermistor type. Also these results indicate the fixed temperature type(bimetal) is not suitable for early stage fire detection.

Analysis of Temperature Rise and Operation Time of Differential Spot Type Detector in Case of Mattress Fire in Multi-family House (다가구 주택의 매트리스 화재 시 차동식 스포트형 감지기의 온도상승 및 동작시간 분석)

  • Kim, Seo-Young;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.3
    • /
    • pp.97-102
    • /
    • 2021
  • This study developed a scenario to understand the reaction rate and operational time according to RTI value of rate of rise detector in each type in case of fire mattress. In the results of analyzing the reaction rate and operational time of detector in each scenario, in case when installing a single detector, the elevated temperature per minute was raised to 8℃/min ~ 9℃/min. In case when installing two detectors, it was raised to 9℃/min ~ 10℃/min. In case when installing three detectors, it was raised to 10℃/min. The horizontal distance between detector and mattress was 1.8m~2.5m. Whenever the number of detectors was increased, the horizontal distance was decreased. The operational time of detector was within maximum 540 seconds and minimum 420 seconds. As the research tasks in the future, there should be the researches on the effects of reaction rate of detector on the evacuation in case of fire through the result value of RSET by setting up the latency until the detector operates, and the researches on the safety by understanding if the operational time of detector is suitable for the evaluation standard of performance-centered design.

Detection of Fire Location And Reliability Improvement of the Conventional Fire Detector and P-type Receiver (재래식 화재감지기와 P형 수신기에 대한 화재위치검출 및 신뢰성 개선)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Yang, Seung-Hyun;Lee, Jae-Jin;Kim, Pil-Young;Lee, Chun-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.39-44
    • /
    • 2011
  • Automatic fire alarm system is set up to automatically detect fire on buildings. Because of economic reasons, P-type receiver and a conventional type fire detector is normally used for automatic fire alarm system in Korea. Because early detection of fire is regarded as important, the need of finding technique of fire location increases. This paper is studied a method to improve a reliability and add a function of fire location detection on a conventional type fire detector and P-type receiver. Fire location is detected by a method that controller attached on the receiver and the detector is read with a time lag. A reliability of fire detection alarm system is improved with a method that false fire alarm is able to decrease using two different principle detector together. This paper is studied for basic data of improvement of low-cost addressable automatic fire alarm system.

A Study on the Response Characteristics of Fire Detector by Full-scale Experiment of Fire Phenomena in the Row House (주택 실물화재실험에 의한 화재감지기 응답특성에 관한 연구)

  • SaKong, Seong-Ho;Kim, Shi-Kuk;Lee, Chun-Ha;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.67-72
    • /
    • 2009
  • This paper is for response feature of fire detectors not only to analysis response feature of fire detector, but also to observe flame spread of inside-building and fire enlargement by using the row house which is supposed to be broken up. Many kinds of popular detectors such as heat type detector(differential type, fixed temperature type, Analogue type)and smoke type(light scattered type, Analogue type, single alarm type) were installed in the house in order to check for the change of temperature by installing of thermocouples. As a result, smoke detectors are better than heat detectors when it comes to making effective fire-detect system in the row house.

Experiment study on the Responsiveness of Spot- Type Heat Detector (열 감지기의 응답특성에 관한 시험연구)

  • Lee, Bok-Yeong
    • Fire Protection Technology
    • /
    • s.19
    • /
    • pp.9-16
    • /
    • 1995
  • The spot-type heat detector is a main component of the automatic fire alarm system intended to signal when heat energy is produced in protected area. The most of protected area in our country is installed spot-type heat detector. On this study, the responsiveness to the change of environmental temp. of spot-type heat detec-tor were obtained and analyzed under specified temp., velocity in accordance with the KOFEIS stan-dard. The experiment was carried under the condition with the change of environmental temp. Concluion of this study is as follows : 1. It was confirmed that the responsiveness of rate-of rise heat detector is sensitive to temp. below 10 degrees above zero. The malfunction appeared at 40 degrees above zero and intended performance is disqualified at 50 degrees above zero. 2. The intended performance of fixed-temp. detector which is maintained for the change of envi-ronmental temp. But the responsiveneness is confirmed instability for the change of environmental temp.

  • PDF

Analysis of the Response Time of a Photoelectric Spot-Type Smoke Detector Depending on the Type of Fires (화원에 따른 광전식 연기감지기 반응시간 분석)

  • Jee, Seung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.89-94
    • /
    • 2013
  • The fire testing performed for smoke detector model approval in Korea tests only one kind of fire smoke. A photoelectric spot-type smoke detector using Mie scattering is affected by the wavelength of light beam and the particle diameter. According to UL (Underwriters Laboratories Inc.) 268 standard, this paper analyze the characteristic of the response for a photoelectric spot-type smoke detector on sale in Korea using various fire smokes. Probability that the response time is included in non-defective range is 100% in paper fire, 90% in wood fire and 75% in flammable liquid fire, 90% in wood fire and 75% in flammable liquid fire. According to the estimation for population mean of the response time choosing a confidence level of 99%, a maximum of 19% for wood fire and that of 38% for flammable liquid fire are defective. As the result of analysis of smoke particle, this paper is found that these results are caused by the smoke particles are wide variations in size or have very black.

A Study on the Problem of Tester for the Field Inspection of the Photoelectric Smoke Detector (광전식연기감지기 현장점검기기의 문제점에 관한 연구)

  • Kim, Shi-Kuk;Yuk, Hyun-Dai;Yang, Seung-Hyun;Jee, Seung-Wook;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.137-144
    • /
    • 2009
  • This paper was studied on the problem of field inspection tester of the photoelectric type smoke detector. The experiment objects were chosen 3 type's testers such as A type (incense), B type (dimethylpolysiloxane), C type (mixtures of hydrocarbon) which were used for performance checking of the photoelectric type smoke detector for the fire protection. The experimental methods were used reliability verification experiment, performance verification experiment and performance change of fire detector by smoke component. It was confirmed through the experiment that the testers had problems of smoke concentration condition and wind velocity condition and smoke component. Consequently, this paper verified that the field inspection testers of the photoelectric type smoke detector had problems in the inspection of fire protection.

A Study on the Development of Standardization Tester for the Field Inspection of the Rate of Rise Spot Type Heat Detector (차동식스포트형열감지기 현장점검용 표준화기기 개발에 관한 연구)

  • Kim, Shi-Kuk;Yuk, Hyun-Dai;Yang, Seung-Hyun;Jee, Seung-Wook;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.85-92
    • /
    • 2009
  • This paper studied on the development of standardization tester for the field inspection of the rate of rise spot type heat detector. It was to find the problems of the 4 type's testers such as A type (electric bulb type), B type (halogen lamp type), C type (heating coil type), D type (fumigator type) which were used to check of the rate of rise spot type heat detector in inspection for the fire protection. To identify those problems, this paper described about the development of standardization tester for the field inspection of the rate of rise spot type heat detector and that have the function of auto setting temperature more $30^{\circ}C$ higher than room temperature and keep the constant temperature. And keep the constant wind velocity of 85cm/sec. Performance verification results of the developed prototype that had same conditions such as the sensitivity test conditions at the type approval of the rate of rise spot type heat detector.

An Experimental Study on the Optimum Installation of Fire Detector for Early Stage Fire Detecting in Rack-Type Warehouses (랙크식 물류창고 조기 화재감지를 위한 최적 화재감지기 설치방법에 관한 실험연구)

  • Choi, Ki Ok;Kim, Dong Suck;Hong, Sung Ho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.38-45
    • /
    • 2017
  • This paper is an experimental study to find an optimal detection method for detecting fire early in a rack-type warehouse stored with goods. In this study, we constructed rack-type structure with the fourth floor of 13.5 m high and conducted fire experiments which were to measure flow of heat/smoke in rack-type structure and response time of fire detectors. The detectors used at experiments were fixed temperature type detectors, rate of rise detectors, photoelectric smoke detectors, air sampling smoke detectors and flame detectors. The used ignition sources are n-heptane fire for response of heat detection and cotton fire for response of smoke detection. The fixed temperature type detectors, rate of rise detectors and photoelectric detectors were installed to every rack level respectively. The results show that the rate of rise detector should be installed every 2 levels and photoelectric smoke detector should be installed every 4 levels for the early stage fire detection. Air sampling smoke detectors can detect fire early in response to control of sensitivity, but there is a problem in false alarm. The fixed temperature detector is not suitable for early stage fire detection in warehouse and flame detector not worked if flame is not visible, so it need to install combination with other detector.

Development Can Air Leak Detector System For Single Compression Head-Line Type Using Pressure Sensor (압력 센서를 이용한 씽글 헤드라인 타입의 캔 에어 리크 검출씨스템 개발)

  • Lee, Jong-Woon
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.506-507
    • /
    • 1992
  • When it comes to the 'Leak Detector System' generally, our country has a large income 'Rotary Type Leak Detector' of foreign goods. The completed development of the 'Line Type Leak-Detector' system was produced to check Whether the containers for small and large on the filling line are auto defective. This system is applied to the filling package Processing during the production and contributed to inproving competiveness of domestic containers manufactures of all society of Industry. Also, high precision and realiablity, very compact size, low cost and Easy set-up etc. by checking the experimental data directly plan, Design and making for '1 Compression Head Control Leak Detector System'. This flexcible system can be equipped with multiple Compression heads depending on the requested prodution test rate and test precision.

  • PDF