• 제목/요약/키워드: Decoupling controller

검색결과 134건 처리시간 0.032초

Optimal Wiener-Hopf Decoupling Controller Formula for State-space Algorithms

  • Park, Ki-Heon;Kim, Jin-Geol
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권4호
    • /
    • pp.471-478
    • /
    • 2007
  • In this paper, an optimal Wiener-Hopf decoupling controller formula is obtained which is expressed in terms of rational matrices, thereby readily allowing the use of state-space algorithms. To this end, the characterization formula for the class of all realizable decoupling controller is formulated in terms of rational functions. The class of all stabilizing and decoupling controllers is parametrized via the free diagonal matrices and the optimal decoupling controller is determined from these free matrices.

초고속 전동기 속도제어를 위한 개선된 비간섭 피드-포워드 제어기 설계 및 해석 (Design and Analysis of an Improved Decoupling Feedforward Controller for Speed Control of SynRM)

  • 오성업;김인수;성세진;최재동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.864-867
    • /
    • 2003
  • In this study, a controller which has a feedforward controller and two additional PI integrators was designed. But if a controller is used by only the integration of a feedforward controller and two additional PI integrators, the capability of a controller will decrease because the decoupling terms of current is feedback as the disturbance. Therefore the feedforward method with the decoupling compensation was proposed. The two additional PI integrators were replaced by two decoupling terms to simplify the calculation. The simulation and experimental using SynRM driving system were performed to verify the design of a improved decoupling feedforward controller.

  • PDF

LMI기법을 이용한 정방 비결합 제어기의 $H_2$설계 ($H_2$ Design for the Square Decoupling Controllers Using LMI Method)

  • 이종성;강기원;조용석;박기헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2645-2647
    • /
    • 2000
  • This paper presents an LMI(Linear Matrix Inequalities) method for designing the optimal decoupling controller. The proposed controller based on the Two-Degree-of-Freedom configuration considers both the performance of controller and decoupling properties. The decoupling controller parameters are obtained from LMI method for computational efficiency.

  • PDF

자전 안정화형 탐색기 주사루프의 비연성 제어기 설계 (A decoupling controller design for the seeker scan loop with a spin-stabilized platform)

  • 유인억;이상정
    • 전자공학회논문지S
    • /
    • 제35S권5호
    • /
    • pp.35-41
    • /
    • 1998
  • This paper presents a decoupling controller of the missile seeker scan loop with a spin-stabilized platform. A precise seeker motion with respect to the scan command is essential for the higher acquisition probability of the target. As the seeker scan loop is a deeply cross-coupled two input two output system, an accurate pointing or scanning for each axis to the target is very difficult, even though provided with the help of a high performance controller. When a decoupling control is applied to the seeker scan loop, the cross-coupling between two axes can be reduced to a remarkable amount. As a low order of controller is required for the real time operation, a PI controller with decoupling filter is suggested and compared with other controllers. A linearized dynamic model of seeker scan loop is used and validated through the comparison of experimental results of step responses.

  • PDF

LMI 기법을 이용한 2자유도 표준모델에 대한 비결합 제어기의 $H_2$ 설계 ([ $H_2$ ]Design for Decoupling Controllers Based on the Two-Degree-of-Freedom Standard Model Using LMI Methods)

  • 이종성;강기원;박기헌
    • 전자공학회논문지SC
    • /
    • 제38권1호
    • /
    • pp.14-26
    • /
    • 2001
  • 본 논문에서는 다변수 시스템을 제어하는 경우 효율적인 제어를 어렵게 만드는 입력과 출력 사이의 결합 효과를 제거하는 비결합 제어기를 설계하였다. 설계된 제어기는 비결합 조건뿐만 아니라 제어계의 성능을 동시에 고려할 수 있는 2자유도 구조를 가지고 있다. 또한 제어기의 계산을 용이하게 하기 위하여 플랜트를 표준모델로 확장시킨 후 전달 행렬을 상태공간 계수로 표현하였다. 그리고 제어기의 계수값들은 선형 행렬 부등식을 이용하여 블록꼴 최적화 문제로 설정하여 구했기 때문에 비결합 및 성능 최적화에 초점을 둔 비결합 제어기의 $H_2$ 설계를 하는데 있어 효과적인 방법을 제시하였다.

  • PDF

Decoupling Controller Design for H Performance Condition

  • Park, Tae-Dong;Choi, Goon-Ho;Cho, Yong-Seok;Park, Ki-Heon
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.874-882
    • /
    • 2011
  • The decoupling design for the one-degree-of-freedom controller system is treated within the $H_{\infty}$ framework. In the present study, we demonstrate that the $H_{\infty}$ performance problem in the decoupling design is reduced into interpolation problems on scalar functions. To guarantee the properness of decoupling controllers and the overall transfer matrix, the relative degree conditions on the interpolating scalar functions are derived. To find the interpolating functions with relative degree constraints, Nevanlinna-Pick algorithm with starting function constraint is utilized in the present study. An illustrative example is given to provide details regarding the solution.

Optimal $H_{2}$ design of the one-degree-of-freedom decoupling controllers

  • Park, Ki-Heon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2093-2098
    • /
    • 2005
  • In this paper, $H_{2}$ designs for the one-degree-of-freedom decoupling control systems are treated for the generalized plant. The optimal $H_{2}$ controller is obtained together with the ones that yield finite $H_{2}$ cost functions under compact assumptions. It is shown that the optimal closed transfer matrix is strictly proper under the reasonable order assumptions on the generalized plant.

  • PDF

New Control Method for Power Decoupling of Electrolytic Capacitor-less Photovoltaic Micro-Inverter with Primary Side Regulation

  • Irfan, Mohammad Sameer;Shin, Jong-Hyun;Park, Joung-Hu
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.677-687
    • /
    • 2018
  • This paper presents a novel power decoupling control scheme with the bidirectional buck-boost converter for primary-side regulation photovoltaic (PV) micro-inverter. With the proposed power decoupling control scheme, small-capacitance film capacitors are used to overcome the life-span and reliability limitations of the large-capacitance electrolytic capacitors. Then, an improved flyback PV inverter is employed in continuous conduction mode with primary-side regulation for the PV power conditioning. The proposed power-decoupling controller shares the reference for primary side current regulation of the flyback PV inverter. The decoupling controller shapes the input current of the bidirectional buck-boost converter. The shared reference eliminates the phase-delay between the input current to the bidirectional buck-boost converter and the double frequency current at the PV primary current. The elimination of the phase-delay in dynamic response enhances the ripple rejection capability of the power decoupling buck-boost converter even with small film capacitor. With proposed power decoupling control scheme, the additional advantage of the primary-side regulation of flyback PV inverter is that there is no need to have an extra current sensor for obtaining the ripplecurrent reference of the decoupling current-controller of the power-decoupling buck-boost converter. Therefore, the proposed power decoupling control scheme is cost-effective as well as the size benefit. A new transient analysis is carried out which includes the source voltage dynamics instead of considering the source voltage as a pure voltage source. For verification of the proposed control scheme, simulation and experimental results are presented.

$H_2$ 기법을 이용한 2자유도 표준 모델의 정방 비결합 제어기 설계 ($H_2$ Design of the Square Decoupling Controller based on the Two-Degree-of-Freedom Standard Model)

  • 최군호;조용석;박기헌
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권8호
    • /
    • pp.980-986
    • /
    • 1999
  • In this paper, the optimal controller which decouples a coupled multivariable system and minimizes a quadratic performance index is proposed. Design of the controller is based on the two-degree-of-freedom standard model. The class of all stabilizing and decoupling controllers is parametrized first and the $H^{2}$optimal controller is obtained by using this parametrized form. An illustrative example for a $2{\times}2$ plant is given.

  • PDF

인덕턴스 변화에 강인한 계통연계형 인버터의 복소 벡터 전류제어기 (Complex Vector Current Control of Grid Connected Inverter Robust for Inductance Variation)

  • 이태진;조종민;신창훈;차한주
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1648-1654
    • /
    • 2016
  • This paper analyzes complex vector current control for the enhanced cross-coupling compensation in accordance with parameter variation in grid-connected inverter system, and verifies through simulation and experiment. Complex vector current control is performed in the synchronous reference frame through d-q transformation. It generates cross-coupling components with rotating nominal angular frequency. In general, cross-coupling elements are compensated by decoupling terms added to output of conventional decoupling PI controller. But, it is impossible to compensate them perfectly which transient response is especially deteriorated such as large overshoot and slow tracking, when variation of grid impedance or measurement error occurs. However, complex vector current control can improve stability and response characteristic of current control regardless of the situation as before. Decoupling controller and complex vector controller are represented through complex forms, and these controllers are analyzed by using frequency response in s-domain, respectively. It is verified that complex vector controller has more superior response characteristic than decoupling controller through MATALB, PSIM and experimental in 5kW grid-connected inverter when L filter parameter is varied from 1.1mH to increase double, 2.2mH.