• Title/Summary/Keyword: Cornea

Search Result 278, Processing Time 0.026 seconds

Antiangiogenic Effect of $AS_2O_3$ on the New Vessels Induced by bFGF in the Rat Cornea (랫드 각막에서 bFGF(basic Fibroblast Growth Factor)로 유발시킨 신생혈관에 대한 $AS_2O_3$의 혈관신생 억제 효과)

  • 김용수;서강문
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.324-328
    • /
    • 2001
  • This study was performed to evaluate the effects of $AS_2O_3$ upon antiangiogenesis in rat cornea, to examine it\`s possible application as an anticancer drug and to provide basic data for further studies of antiangiogenetic mechanism of $AS_2O_3$ . Angiogenesis was induced by cornea micropocket assay, as previously described. Sixteen of forty-eight eyes of Sprague-Dawley rats were randomly assigned to one of three groups, namely, only a bFGF group(control group), and a group treated by $AS_2O_3$ ($AS_2O_3$ group). After pellet implantation, we measured the number of new vessels, vessel length and clock hour of neovascularization, and area of neovascularization was determined using a mathematical formula. New vessels growing began at day 3, number of vessels in $AS_2O_3$ group were significantly more less than those in control group (p<0.05). The length of vessels of $AS_2O_3$ group was significantly shorter than that of control group after day 3(p<0.05). The clock hours of all group were slowly increased at all days but $AS_2O_3$ group was inhibited more than control group. Neovascularization areas of $AS_2O_3$ group were more significantly inhibited than those of control group (p<0.05). This study showed that $AS_2O_3$ had powerful antiangiogenetic effects and it would be useful in the choice of anticancer drug.

  • PDF

A Retrospective Study of Intracorneal Hemorrhage in 6 Small Breeds Dogs (2007~2011) (소형견의 각막내 출혈에 대한 후향적 연구: 6예 (2007-2011))

  • Yoo, Sukjong;Ji, Dongbeom;Kim, Hwiyool;Seo, Kangmoon;Jeong, Manbok
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.288-291
    • /
    • 2013
  • The purpose of the retrospectivestudy was to describe the clinical findings and treatment of intracorneal hemorrhage (ICH) in canine small breeds. The medical records of 6 dogs with ICH (January 2007 to November 2011) were examined to obtain the breed, age, gender, affected eye, cornea area, treatment, and follow-up. A total of 12 corneal areas in 8 eyes were identified in 6 dogs (4 Yorkshire terriers, 1 Poodle, and 1 Maltese). The mean age ${\pm}SD$ at the first presentation was $12.3{\pm}2.8$years, and 5 of 6 dogs were over 12 years old. ICH caused by corneal neovascularization was the most common in the nasal area of cornea (nasal 6/12, superior 4/12, and inferior 2/12) and recurred in different area of same or other cornea in 3 dogs. There were no concomitant corneal diseases at the initial presentation. All dogs affected were treated with combination of topical antibiotics and steroids and subconjuctival injection of steroids. The results showed that ICH can be treated with long-term medical therapies. In addition, further study would be needed to identify specific causes for the intracorneal hemorrhage.

The morphological study of Cornea in Man College Students (남자대학생들의 각막 형태 연구)

  • Kim, Douk Hoon;Yoo, Jae Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.89-93
    • /
    • 2002
  • The physiology and morphology of cornea has effected on the ocular refractive status. Therefore the measurement of the anterior corneal surface by keratometer is used the treatment of the spectacles and contact lens by optician, optometrist, and ophthalmologist. Furthermore, currently the most corneal topographic mapping system have used the clinical optical shop, eye research center, and eye hospital. Because this method have a very fine data comparative to the previous instrument. The authors have measurement the cornea of the man college students by the corneal topographic mapping method. Especially this data will applied the clinical practice for the contact lens fitting. Especially in Korea, many man college students use the contact lens for the visual acuity and a beauty. Therefore the contact lens wear have increase per every year.

  • PDF

Bevacizumab accelerates corneal wound healing by inhibiting TGF-βexpression in alkali-burned mouse cornea

  • Lee, Sung-Ho;Leem, Hyun-Sung;Jeong, Seon-Mi;Lee, Koon-ja
    • BMB Reports
    • /
    • v.42 no.12
    • /
    • pp.800-805
    • /
    • 2009
  • This study investigated the effect of subconjunctival injections of bevacizumab, an anti-VEGF antibody, on processes involved in corneal wound healing after alkali burn injury. Mice were divided into three groups: Group 1 was the saline-treated control, group 2 received subconjunctival injection of bevacizumab 1hr after injury and group 3 received bevacizumab 1 hr and 4 days after injury. Cornea neovascularization and opacity were observed using a slit lamp microscope. Corneal repair was assessed through histological analysis and immunostaining for CD31, $\alpha$-SMA, collagen I, and TGF-$\beta$2 7 days post-injury. In group 3, injection of bevacizumab significantly lowered neovascularization and improved corneal transparency. Immunostaining analysis demonstrated a reduction in CD31, $\alpha$-SMA and TGF-$\beta$2 levels in stroma compared to group 1. These results indicate that bevacizumab may be useful in reducing neovascularization and improving corneal transparency following corneal alkali burn injury by accelerating regeneration of the basement membrane.

Ablation Depth of Cornea and Munnerlyn Formula in Refractive Keratectomy (각막굴절교정절제술에서 각막의 절제 깊이와 Munnerlyn 식)

  • Choi, Woon Sang;Kim, Yoon-Kyung;Lee, Sung Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.121-124
    • /
    • 2007
  • Ablation depth of cornea in refractive keratectomy was calculated by Munnerlyn formula. The calculations were preformed for various optical diameter (4 mm~8 mm) and various amount of corrections (-1 Dptr ~ -12 Dptr). The results to be compared with the Munnerlyn approximated formula had little effect within lower corrections, but in higher corrections > 6 Dptr can be occurred the error of 1 Dptr. Although ablation depth were evaluated, the results were only calculated by mathematical model of geometric assumptions. Because ablation depth can vary with operation conditions, the correction factor should be considered not only ablation depth by Munnerlyn formula but also surgeon-specific factor.

  • PDF

Analysis on the corneal thickness and anterior chamber depth of the Keratoconus using Pentacam

  • Kim, Douk-Hoon;Sapkota, Kishor
    • Journal of Korean Clinical Health Science
    • /
    • v.6 no.1
    • /
    • pp.1089-1096
    • /
    • 2018
  • Purpose: To investigate the corneal thickness and anterior chamber depth (ACD) of eyes with Keratoconus in the Korean population with the Pentacam. Methods: The subjects consisted of 84 eyes from Keratoconic adults aged 7-59 years during 2010. The thinnest area, apex zone, and pupil centre of the corneal thickness were measured using the Pentacam pachymetry. ACD value was also measured with Pentacam. Results: There was a statistically significant relationship between thickness of the cornea at the apex area and the pupil centre (p=0.0001). However, there was no statistical difference (p>0.5) in the mean thickness of thinnest area, apex zone, pupil centre of cornea between right eye and left eye. Also, correlation between ACD and corneal thickness in all subjects had no statistical differences (p>0.05) in all subjects. Conclusion: These results suggested that the regional thickness of cornea and ACD with Pentacam can provide correct and useful diagnostic information of the morphology of Keratoconus for the RGP contact lens and diagnosis of abnormal corneal refraction surgery.

Effects of Natural and Chemical Disinfectants to Epithelium and Endothelium of Rabbit's Cornea - Scanning Electron Microscopy (천연보존제와 화학보존제가 가토안의 각막 상피, 내피에 미치는 영향- 주사전자현미경적 관찰)

  • Kim, In-Suk;Jeon, Chang-Jin
    • Applied Microscopy
    • /
    • v.35 no.3
    • /
    • pp.129-134
    • /
    • 2005
  • The cytotoxicity that chemical disinfectants of K products and natural disinfectants of naringin & chitosan well-known preservative, have on endothelium and epithelium of rabbit's cornea were obseved by scanning electron microscope. The main component of naringin is grapefruit seed extract, which is one of the flavonoid widely recognized as natural antioxidants and used as preserved food and cosmetics. The chitosan also wildly distributed epithelium of crustacea, epidermis of insects, mould, fungi and so on. It is no harm of cytotoxicity of human body and recognized of antibacterial for various of bacteria. This study was performed to examine the cytotoxicity of natural and chemical preservative.

Intraocular Foreign Body Entering the Anterior Chamber Through the Mouth: A Case Report

  • Kim, Joon-Young;Kim, Kyung-Hee;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.34 no.1
    • /
    • pp.58-60
    • /
    • 2017
  • An 11-year-old, castrated Maltese dog presented with a 3-week history of periocular swelling, epiphora, and intermittent strabismus. On examination, a foreign body was observed in the anterior chamber, along with orbital cellulitis. Severe gingivitis and plaque accumulation were also diagnosed. The foreign body was surgically removed, and dental prophylaxis and dental extraction were performed. The foreign body entrance could not be found intraoperatively, and the foreign body, later identified as a feather, was removed through a clear corneal incision. The right maxillary molar, which had periodontal inflammation, was also extracted. One day postoperatively, severe hypopyon developed, although the periocular swelling was reduced. These signs persisted despite topical and systemic antibiotic and anti-inflammatory therapy; therefore, the right eye was enucleated 1 week later. Intraoperatively, a fistula was found connecting the orbital medial wall, right maxillary molar root, and sclera. The fistula entered the dorsomedial sclera approximately 7 mm behind the limbus. Enterobacteria were cultured from the area. Foreign bodies can enter the anterior chamber not only through the cornea, but also through the mouth. Therefore, when the entry point cannot be found in the cornea, a careful dental examination is required, and the foreign body must be removed through the sclera rather than the cornea.

Analysis on the Depressing Force to the Cornea by Fitted Spherical Contact Lens (구면 콘택트렌즈의 피팅에 따른 각막 부착력 해석)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.97-106
    • /
    • 2011
  • Purpose: This review article was written to theoretically compare the depressing force (pressure, adhesion) to the cornea between when the spherical lenses were being tightly and flat fitted. Methods: Mathematical equations and their numerical solution programs (model) were formulated to calculate the depressing (adhesion) force to the cornea by both the tightly and flat fitted contact lenses. Based on this proposed model the effects of parameters characterizing a contact lens such as BCs, diameters, edge shape and corneal shape (ratio of long and short corneal axis, p) on the depressing force to the cornea were predicted/analyzed in both tightly and flat fitting regimes. Results: Corneal adhesion increased as the corneal p-value increased. Adhesion increase caused by the increased p-value was much larger in flat fitted case than in tight fitted one. Corneal adhesion reduced abruptly as the BC increased in flat fitting regimes while the adhesion rise was insignificant in tight fitting ones. Reduction in corneal adhesion due to lens-size increase was predicted to be insignificant in both tight and flat fitting regimes. Both the lens edge shape (edge angle) and thickness were relevant only in tight fitting regime. Corneal adhesion increased as the increased with tight-fitted lenses. As the thickness of tight fitted lenses increased, corneal adhesion inversely decreased. Conclusions: The two most significantly affecting the depressing force to cornea were found to be the degree of corneal bending toward the periphery and the BCs of lenses.

Change of Corneal Shape with Soft Contact Lens Type (소프트콘택트렌즈의 유형에 따른 각막형태의 변화)

  • Woo, Chul-Min;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.111-120
    • /
    • 2014
  • Purpose: This study was to investigate changes in the thickness of cornea, curvature of cornea, and aberration depending on the water contents, materials, and refractive power of contact lens. Methods: The differences in the corneal thickness between pre- and post-wearing the lenses were compared using 5 kinds of lenses. The changes in the corneal thickness, the curvatures of the anterior and posterior cornea, and high order aberration (HOA) before and after wearing the lenses were investigated at the center of the cornea, and the different distance and the direction away from the center of the cornea. For the equipments of measurement, ORB ScanII (Bausch & Lomb Inc, ver 3.14) was used to measure the corneal topography and thickness, and Zywave (Bausch & Lomb Inc, ver 5.20) was used to analyze the high order aberration. Results: Five (S1, S2, S3, T1, T2) of the lens was used for this study, excluding the lens T2 lens has four lenses and the thickness of the corneal shape, but the impact is minimal. In the case of the hydrogel soft contact lenses (T2 lens) with low oxygen permeability, the corneal thickness showed distinct increasing patterns. The high order aberration and coma aberration were most changed in the silicon hydrogel toric lens, while the depth of anterior was most changed in the hydrogel toric lens. Conclusion: Among the 5 kinds of contact lenses with different water contents, materials, and refractive power used for this study, the corneal shape change was small for the lenses with an oxygen permeability (Dk) of more than 28, and the largest for the lenses with a very low oxygen permeability.