• Title/Summary/Keyword: Bio signal

Search Result 666, Processing Time 0.032 seconds

Driving Performance Evaluation Using Bio-signals from the Prefrontal Lobe in the Driving Simulator

  • Kim, Young-Hyun;Kim, Yong-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.319-325
    • /
    • 2012
  • Objective: The aim of this study was to develop the assistive device for accelerator and brake pedals using bio-signals from the prefrontal lobe in the driving simulator and evaluate its performance. Background: There is lack of assistive devices for the driving in peoples with disabilities in Korea. However, if bio-signals and/or brain waves are used at driving a car, the people with serious physical limitations can improve their community mobility. Method: 15 subjects with driver's license participated in this study for experiment of driving performance evaluation in the simulator. Each subject drove the simulator the same course 10 times in three separated groups which use different interface controllers to accelerate and brake: (1) conventional pedal group, (2) joystick group and (3) bio-signal group(horizontal quick glance of the eyes and clench teeth). All experiments were recorded and the driving performances were evaluated by three inspectors. Results: Average score of bio-signal group for the driving in the simulator was increased 3% compared with the pedal group and was increased 9% compared with the joystick group(p<0.01). The subjects using bio-signals was decreased 44% in number of deduction compared with others because the device had the built-in modified cruise control. Conclusion: The assistive device for accelerator and brake pedals using bio-signals showed significantly better performance than using general pedal and a joystick interface(p<0.01). Application: This study can be used to design adaptive vehicle for driving in people with disabilities.

Development of Detection and Analysis System for Electrogastrographic Signal (위전도신호의 측정 및 분석시스템 개발)

  • 한완택;김인영
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.261-268
    • /
    • 1998
  • Electrogastrography(EGG), the cutaneous recording of the myoelectrical activity of the stomach using surface electrodes, is a non-invasive technique to detect gastric motility disorder, We developed a detection and analysis system for the EGG signal, which consists of hardware(bio-amplifier, filter) and softwere(user interface, analysis algorithm, patient database). The EGG signal was amplified and filtered by 3 channel bio-amplifiers, and simultaneously digitized and stored on IBM PC with a sampling frequency of 16 Hz. The stored EGG signal was analyzed using developed algorithm to extract clinically useful information from the signal. The developed system has tested through animal experiments, and is under clinical evaluation.

  • PDF

Alarm System for Sudden Infant Death using Bio-Signals (생체 신호를 활용한 영아 돌연사 알람 시스템)

  • Yun, Su-Jeong;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.197-202
    • /
    • 2016
  • In this paper, a danger signal to tell caregivers when a dangerous situation occurs, the bio-signal analysis in infants to prevent sudden infant death sudden infant death propose a monitoring system. The Sudden infant death (SID) refers to a healthy baby is unexplained deaths between birth year in the month. Sudden infant death proposed monitoring system is composed of a processor unit and the monitoring and alarm part for processing part and the biological signal sensing biological signals. Using the PPG sensor to sense the bio-signal and the processor unit the signal obtained through the sensor by removing the motion artifact was able to alarm and monitoring the parent.The proposed system will send the alarm to monitoring and alerting caregivers if the risk situation by analyzing the heart rate of the infant. With the actual implementation of the system to evaluate the performance of the monitoring system.

Implantable Nerve Cuff Electrode with Conductive Polymer for Improving Recording Signal Quality at Peripheral Nerve (말초 신경 신호 기록의 효율성 개선을 위한 전도성 폴리머가 적용된 생체삽입형 커프형 신경전극)

  • Park, Sung Jin;Lee, Yi Jae;Yun, Kwang-Seok;Kang, Ji Yoon;Lee, Soo Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.22-28
    • /
    • 2015
  • This study demonstrates a polyimide nerve cuff electrode with a conductive polymer for improving recording signal quality at peripheral nerve. The nerve cuff electrodes with platinum (Pt), iridium oxide (IrOx), and poly(3,4-ethylenedioxythiophene): p-toluene sulfonate (PEDOT:pTS) were fabricated and investigated their electrical characteristics for improving recorded nerve signal quality. The fabricated nerve cuff electrodes with Pt, IrOx, and PEDOT:pTS were characterized their impedance and CDC by using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry. The impedance of PEDOT:pTS measured at 1 kHz was $257{\Omega}$, which was extremely lower than the value of the nerve cuff electrodes with IrOx ($15897{\Omega}$) and Pt ($952{\Omega}$), respectively. Furthermore, the charge delivery capacity (CDC) of the nerve cuff electrode with PEDOT:pTS was dramatically increased to 62 times than the nerve cuff electrode with IrOx. In ex-vivo test using extracted sciatic nerve of spaque-dawley rat (SD rat), the PEDOT:pTS group exhibited higher signal-to-interference ratio than IrOx group. These results indicated that the nerve cuff electrode with PEDOT:pTS is promising for effective implantable nerve signal recording.

A Survey of Objective Measurement of Fatigue Caused by Visual Stimuli (시각자극에 의한 피로도의 객관적 측정을 위한 연구 조사)

  • Kim, Young-Joo;Lee, Eui-Chul;Whang, Min-Cheol;Park, Kang-Ryoung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.195-202
    • /
    • 2011
  • Objective: The aim of this study is to investigate and review the previous researches about objective measuring fatigue caused by visual stimuli. Also, we analyze possibility of alternative visual fatigue measurement methods using facial expression recognition and gesture recognition. Background: In most previous researches, visual fatigue is commonly measured by survey or interview based subjective method. However, the subjective evaluation methods can be affected by individual feeling's variation or other kinds of stimuli. To solve these problems, signal and image processing based visual fatigue measurement methods have been widely researched. Method: To analyze the signal and image processing based methods, we categorized previous works into three groups such as bio-signal, brainwave, and eye image based methods. Also, the possibility of adopting facial expression or gesture recognition to measure visual fatigue is analyzed. Results: Bio-signal and brainwave based methods have problems because they can be degraded by not only visual stimuli but also the other kinds of external stimuli caused by other sense organs. In eye image based methods, using only single feature such as blink frequency or pupil size also has problem because the single feature can be easily degraded by other kinds of emotions. Conclusion: Multi-modal measurement method is required by fusing several features which are extracted from the bio-signal and image. Also, alternative method using facial expression or gesture recognition can be considered. Application: The objective visual fatigue measurement method can be applied into the fields of quantitative and comparative measurement of visual fatigue of next generation display devices in terms of human factor.

Wireless Bio-signal Monitoring System (무선 생체신호 모니터링 시스템)

  • Kim, Do-Kyoung;Lee, In-Kwang;Cha, Eun-Jong;Kim, Kyung-Ah
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2055-2056
    • /
    • 2011
  • As rapid aging and high economic level, people are interested in their wellness. And it needs to examine the condition of their health constantly. Proposed device can measure bio-signal by connecting several measurement modules such as spirometric module, blood glucose measurement module, uro-flow measurement module and temperature measurement module. These modules can be chosen as occasion demands. In addition, developed user program enables patients to monitor bio-signal at their own place via the personal computer.

  • PDF

An Analysis on the Changes in ERP According to Type of Stimuli about Fear of Crime (범죄의 두려움에 대한 자극의 유형에 따른 ERP 변화 분석)

  • Kim, Yong-Woo;Kang, Hang-Bong
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.12
    • /
    • pp.1856-1864
    • /
    • 2017
  • The ultimate goal of multimedia in bio-signal research is to approach multimedia contents through bio-signal. Hence it is important to interpret user's emotions by analyzing his or her bio-signals. In this paper, we construct ERP task of oddball component to analyze EEG signal between normal stimuli and fear stimuli and measure EEG during ERP task. The results from extracted ERP component show that there is a difference in N200 in visual stimuli, P300 in auditory stimuli, and N100 and P300. Moreover, there are larger changes in audiovisual stimuli, indicating that users recognize greater fear of crime when visual and auditory stimuli are simultaneously presented.

Design of Bio-signal Acquisition System in MRI Environment (MRI 내에서의 생체신호 측정 시스템 설계)

  • Jang, Bong-Ryeol;Park, Ho-Dong;Lee, Kyoung-Joung
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.871-872
    • /
    • 2006
  • In this paper, we designed bio-signal acquisition system in Magnetic Resonance Imager(MRI) Environment. In MRI Environment, Strong RF Pulse and Gradient Field Switching Noise exist and can cause distortion of ECG. By this, ECG can lose their important information. So we proposed a bio-signal acquisition system with robust immunity to RF pulse and gradient switching noise. In conclusions, the proposed system showed the prevent saturation of measured biosignal and possibility of using cardiac gating and respiration gating method.

  • PDF

Development of bio-signal analysis system applying source code based on various algorithm development tools (다양한 알고리즘 개발 툴 기반의 소스 코드를 적용한 생체신호 분석 시스템 개발)

  • Ju, Mun-Il;Kim, Won-Il;Kim, Hui-Cheol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.238-240
    • /
    • 2018
  • Recently, healthcare services have been developed and studied using various bio-signal analysis tools. Most bio-signal analysis studies utilize Matlab and R Programming. However, in order to apply the algorithm developed by Matlab and R Programming to the system, it is necessary to convert the source code. This paper proposes a smart interface that can skip source code conversion.

  • PDF

Optical waveguide sensors using optical birefringence of evanescent fields (소산파의 복굴절을 이용한 광 도파관 센서)

  • Son, K.S.;Lee, H.Y.;Kim, W.K.;Lee, S.S.;Park, S.S.;Kwon, S.W.;Lee, E.C.;Park, J.W.;Ju, H.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.07a
    • /
    • pp.309-310
    • /
    • 2008
  • Polymer optical waveguides are fabricated with high-index materials deposited to strengthen exciations of evanescent field whose birefringence is utilized for optical sensing. Optical sensing properties are examined as a function of time, using different types of analyte solutions to extract noise-free signal induced by evanescent field birefringence. It is observed that sensing signal can be free of initial noise that may obscure real signal recognition, when glycerol is used for sensing characterization, due to slow accumulation process following adsorption of analyte material onto the sensing surface of the waveguide.

  • PDF