Abstract

In this paper, a danger signal to tell caregivers when a dangerous situation occurs, the bio-signal analysis in infants to prevent sudden infant death sudden infant death propose a monitoring system. The Sudden infant death (SID) refers to a healthy baby is unexplained deaths between birth year in the month. Sudden infant death proposed monitoring system is composed of a processor unit and the monitoring and alarm part for processing part and the biological signal sensing biological signals. Using the PPG sensor to sense the bio-signal and the processor unit the signal obtained through the sensor by removing the motion artifact was able to alarm and monitoring the parent.The proposed system will send the alarm to monitoring and alerting caregivers if the risk situation by analyzing the heart rate of the infant. With the actual implementation of the system to evaluate the performance of the monitoring system.

본 논문에서는 영아 돌연사를 방지하기 위해 영아의 생체신호를 분석하여 위험상황이 발생했을 때 보호자에게 위험신호를 알려주는 영아 돌연사 모니터링 시스템을 제안한다. 영아 돌연사(SID)는 생후 한 달에서 일년 사이의 건강한 아기가 원인불명으로 사망하는 것을 말한다. 제안한 영아 돌연사 모니터링 시스템은 생체신호를 센싱하는 부분과 생체 신호를 처리하는 프로세서부와 모니터링 및 알람부분으로 구성된다. PPG 센서를 사용하여 생체신호를 센싱하고 프로세서부에서는 센서를 통해 획득한 신호를 동잡음을 제거하여 부모에게 알람 및 모니터링 할 수 있게 하였다. 제안한 시스템은 영아의 심박동을 분석하여 위험상황인 경우 보호자에게 모니터링 및 경고 알람을 보내게 된다. 시스템의 실제 구현을 통해 모니터링 시스템의 성능을 평가하였다.

Keywords

References

  1. D. I. Tudehope and G. Cleghorn, "Home monitoring for infants at risk of the sudden infant death syndrome.", Journal of Paediatrics and Child Health, Volume 20, Issue, pp.137-140, 1984. https://doi.org/10.1111/j.1440-1754.1984.tb00062.x
  2. MG MacDonald, MMK Seshia, and MD Mullett, "Avery's neonatology: pathophysiology & management of the newborn", Lippincott williams & wilkins, Philadelphia, 2005
  3. Corbishley P, and Rodriguez-Villegas E, "Breathing detection: towards a miniaturized, wearable, battery-operated monitoring system",Biomedical Engineering, IEEE Transactions on, vol. 55, no. 1, pp.196-204, 2008 https://doi.org/10.1109/TBME.2007.910679
  4. J.S. O, J. J. Kang, M. J. Lim, and K. Y. Lee, "Design and Implementation of an Emotion Recognition System using Physiological Signal", The Journal of The Institute of Internet, Broadcasting and Communication(JIIBC), Vol. 10, No. 1, pp. 57-62, 2010
  5. Linti C, Horter H, Osterreicher P, and Planck H, "Sensory baby vest for the monitoring of infants", In Wearable and Implantable Body Sensor Networks, International Workshop on, IEEE, 2006
  6. Tewel N, "Application of MEMS accelerometer for baby apneamonitoring under home conditions", Acta Bio-Optica et Informatica Medica. Inzynieria Biomedyczna, vol. 16, no. 4, pp. 389-393, 2010
  7. Ziganshin EG, Numerov MA, and Vygolov SA, "UWB baby monitor", In Ultrawideband and Ultrashort Impulse Signals, 5th International Conference on, pp. 159-161, 2010
  8. J.H. Kang, B.H. Cho, J. Lee, Y. Chee, I.Y. Kim, and S. I. Kim, "A Study on Accelerometer Based Motion Artifact Reduction in Photoplethysmography Signal." Journal of Biomedical Engineering, Vol. 28, No. 3, pp.369-376, 2007.
  9. N.V. Thakor and Y.S. Zhu, "Applications of Adaptive Filtering to ECG Analysis : Noise cancellation and arrhythmia detection," IEEE Trans. Biomed. Eng,Vol.38, No.8, pp.785-794, 1991. https://doi.org/10.1109/10.83591
  10. H.W. Lee, J.W. Lee, W.G. Jung, and G.K. Lee, "The Periodic Moving Average Filter for Removing Motion Artifacts from PPG Signals," Internal Journal of Control, Automation, and System, Vol. 5, No. 6, pp.701-706, 2007.
  11. G.Y. Kim, J.S. Park, G.H. Na, M.H. Park, G.Y. O, Y.S. Yang, I.T. Hwang, and J.S. Park, "Normal Variation and Predictive Value for Pregnancy Outcome of Fetal Heart Rate in the Early First Trimester", Obstetrics & Gynecology Science, Vol.46, no11, pp.2134-2138, 2003