• Title/Summary/Keyword: Air condition(A/C)

Search Result 922, Processing Time 0.045 seconds

Smart Air Condition Load Forecasting based on Thermal Dynamic Model and Finite Memory Estimation for Peak-energy Distribution

  • Choi, Hyun Duck;Lee, Soon Woo;Pae, Dong Sung;You, Sung Hyun;Lim, Myo Taeg
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.559-567
    • /
    • 2018
  • In this paper, we propose a new load forecasting method for smart air conditioning (A/C) based on the modified thermodynamics of indoor temperature and the unbiased finite memory estimator (UFME). Based on modified first-order thermodynamics, the dynamic behavior of indoor temperature can be described by the time-domain state-space model, and an accurate estimate of indoor temperature can be achieved by the proposed UFME. In addition, a reliable A/C load forecast can be obtained using the proposed method. Our study involves the experimental validation of the proposed A/C load forecasting method and communication construction between DR server and HEMS in a test bed. Through experimental data sets, the effectiveness of the proposed estimation method is validated.

Attachment of the Air Heat Exchanger for COP Improvement in the Heat Pump (열펌프 성능향상을 위한 공기 열교환기 부착효과)

  • 노정근;송현갑;박용규
    • Journal of Biosystems Engineering
    • /
    • v.27 no.3
    • /
    • pp.235-240
    • /
    • 2002
  • Performance of the heat pump with attaching an air heat exchanger was investigated in the heating condition when the air heat exchanger was worked in the ambient air temperature of -5 to 11$\^{C}$ and air flow rate of 542 to 747 ㎡/h. Performance tests for heating condition were conducted in an experimental room equipped with heat pump. The performance tests were performed in a ambient temperature of -4 ∼ 11$\^{C}$, and room temperature of 4∼22$\^{C}$ respectively. Measured data(temperature, capacity of heat transfer and consumption of electronic power) were analyzed to the efficiency of HEEVA(Heat Exchanger fur the Evaporator), overall heat transfer coefficient and COP of heat pump. The results of inlet temperature for evaporator increased that the temperature was 2 ∼6$\^{C}$, and inlet temperature for condenser decreased that the temperature was 3 ∼ 8$\^{C}$. The results of comparing efficiency of HEEVA for the ratio of heat exchange between hot air and cold air showed that efficiency were considered to 91% because of the ratio of 83∼98%. The results of comparing of COP for the heat pump increased that improvement COP was approximately 0.3∼7.5 than HEEVA had not been operated.

A study on frost generation and difrosting mechanism on evaporating tubes for Air-conditioning system (냉동공조용 증발기에서 서리의 발생 및 제상 메커니즘에 관한 연구)

  • Jee, Jae-Hoon;Kim, Chang-Bok;Kim, Myung-Hwan;Oh, Cheol
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.166-171
    • /
    • 2005
  • In this experiment study, to acquire elementary data for explaining to generate frost layer in the fin - tube evaporator. the experiment condition is to supply air on 0.3m/s, 0.6m/s, 0.9m/s and inlet air temperature is kept constantly $20^{\circ}C$, supplied air relative humidity is 70%, 80, 90%. And brine temperature in the copper tube was kept $-15^{\circ}C$ because, generally cooling temperature range is constantly $-15^{\circ}C$ in the heat exchanger for air conditioning system. in conclusion, through this experiment, we did compare with frost layer and frost quantity in each condition and examine these data

  • PDF

Thermal Analysis of a Spent Fuel Storage Cask under Normal and Off-Normal Conditions

  • Lee, J. C.;K. S. Bang;K. S. Seo;Kim, H.D.;Park, B. I.;Lee, H. Y.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.601-608
    • /
    • 2003
  • Thermal analyses have been carried out for a spent fuel dry storage cask under normal and off-normal conditions. Environmental temperature is assumed to be $15^{\circ}C$ under the normal condition. The off-normal condition has an environmental temperature of $38^{\circ}C$. An additional off-normal condition is considered as a partial blockage of the air inlet ducts. Two of the four air inlet ducts are assumed to be completely blocked. The maximum temperatures of the fuel rod and concrete overpack were lower than the allowable values under the normal condition. Temperature distributions for the off-normal conditions were slightly higher than the normal conditions.

  • PDF

Selection of Number of Fans in an Air-Cooled Condenser of a 150 MW Thermal Power Plant according to Ambient Air Temperature (대기온도 변화에 따른 150 MW 화력발전소용 공랭식 복수기 송풍기수 선정)

  • Hwang, Yong-Hoon;Heo, Ki-Moo;Yoon, Sung-Hoon;Moon, Yoon-Jae;Lee, Jae-Heon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.10 no.4
    • /
    • pp.24-28
    • /
    • 2014
  • During this study, number of fan by ambient air temperature that condenser pressure satisfies steam turbine exhaust pressure condition with intervals of $3^{\circ}C$ within the 150 MW thermal power plant site temperature range of $-17.1^{\circ}C$ to $36.7^{\circ}C$ was reviewed. An air cooled condenser changes its operating pressure influenced by cooling air circulation amount by atmospheric temperature and number of fan. For stable power plant operation, these were confirmed to maximize a quantity of air-cooled condenser fans at above or equal from design ambient temperature and to reduce an amount of circulating air to an air cooled condenser by depending on a quantity of fan considering exhaust pressure operation condition of a steam turbine at below design ambient temperature.

  • PDF

A Study on the Evaluation of Thermal Environment according to the Location of Ceiling Type Unit in Classroom (교실 천장형 Unit의 위치에 따른 온열환경 평가 연구)

  • Cho, Sung-Woo;Choi, Jeong-Min;Son, Young-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.135-140
    • /
    • 2005
  • Installation of ceiling type unit is achieved by one of efforts for agreeable classroom environment embodiment along with economic growth. But research about changing the position of ceiling type unit is lacking in present. Therefore, this thesis is to study the thermal environment of 5 different position cases of ceiling type, namely Case A, B, C, D, E. Here, Case C is the case that has the position of ceiling type center of the classroom and the other 4 alternatives are 0.7 m away from the Case C according to x and z axis. In this thesis temperature distributions, air current distribution, heat amenities such as PMV of occupants are analyzed as the environmental factors. Through these factors, Case C and Case D are the better position alternatives than the alternatives of Case A, Case B and Case E because the latter cases the air current reaches directly to indoor occupants so that occupants feel chilly. This thesis has a conclusion under the condition of only one inlet air temperature and seat arrangement. But afterwards more inlet air condition and seat arrangement must be considered.

  • PDF

Experimental Study on Performance Evaluation of System A/C using PWM or Inverter Method (Heating Characteristics at Low Temperature Conditions) (PWM 방식과 인버터 방식을 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(난방저온 특성))

  • 김대훈;전용호;권영철;이윤수;문제명;홍주태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.551-556
    • /
    • 2003
  • The present study concerns an experiment on the heating characteristics of a system air-conditioner (A/C) using PWM method or inverter method at low temperature con-ditions. The compressors used are digital scroll type and BLDC inverter type. Under the low outside temperature condition, -5$^{\circ}C$, -1$0^{\circ}C$, -15$^{\circ}C$, heating capacities and COPs are mea-sured by the psychometric calorimeter using air enthalpy method. Also, outlet air temperatures at heating operation mode are measured at -5$^{\circ}C$, -1$0^{\circ}C$ and -15$^{\circ}C$. Experimental results show that COPs of the system A/C using a PWM method are more effective than those of the inverter method at heating operation mode. Although the heater is on, COPs of PWM method are similar to those of BLDC inverter method. Moreover, the heating capacities of PWM method at -5$^{\circ}C$, -1$0^{\circ}C$ and -15$^{\circ}C$ are larger about 10~20% and outlet air tempe-rature at -15$^{\circ}C$ is larger about 10%, compared to the inverter method.

The Resistivity Properties and Adhesive Strength of Cu Thin firms Fabricated by EBE Method (전자빔 증착법으로 제작한 Cu 박막의 부착력과 저항율 특성)

  • Paik, Sang-Bong;Shin, Joong-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.422-426
    • /
    • 2003
  • Cu thin films of $6000{\AA}$ thickness were deposited by Electron Beam Evaporation(EBE) method on the glass. The resistivity properties and adhesion of Cu thin films were investigated by various annealing and substrate temperature. Cu thin films were annealed in the air and vacuum condition for 10 min after the deposition. The resistivity and adhesion(the force required to separate films from substrates) was measured by 4-point probe and scratch testing. The resistivity of non-annealing Cu thin films was distinguished more substrate temperature loot than substrate temperature R.T, $200^{\circ}C$. In the case of air condition annealing, as heating temperature was increased, the resistivity was decreased. In the case of vacuum condition annealing, the resistivity was increased at heating temperature $200^{\circ}C$. The best resistivity($1.72\;{\mu}{\Omega}{\cdot}cm$) of Cu thin films was obtained by the air condition heating temperature $200^{\circ}C$ at the substrate heating temperature $100^{\circ}C$. As a result of scratch testing, adhesion was increased by annealing. And maximum adhesion had 600 gf.

  • PDF

Oplimum Design Conditions for a Basic Refrigeration Cycle (냉동사이클의 최적 설계조건)

  • Cho, Sung-Whan
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.4
    • /
    • pp.356-361
    • /
    • 1986
  • An optimum design condition for a basic refrigeration cycle is defined as the condition which minimizes the total cost of heat exchanges (condenser and evaporator) and compressor for the refrigeration effect. Thermodynamic properties of ammonia (R717) are approximated by rational functions in order to obtain the optimum condition for a basic refrigeration cycle. Optimum condition depends on the heat capacity rates (mass flow rate times specific heat) of cooling water and brine used in condenser and evaporator. The difference between the cooling water temperature and condensation temperature at the optimum condition increases as the heat capacity rates and the coat of heat exchangers relative to the cost of compressor increase. Numerical examples of optimum conditions are obtained when the condensation temperature is $30^{\circ}C$ and the evaporator temperature is $-10^{\circ}C$.

  • PDF

Investigation of the Environment for Conservation in the Facilities of Exhibition and Collection for Cultural Properties (문화재 전시 및 수장시설 내에서의 보존환경 조사연구)

  • Hong, Jung-Ki;Kim, Sa-Dug;Kim, Soon-Kwan;Kang, Dai-Ill;Lee, Myeong-Hui
    • 보존과학연구
    • /
    • s.22
    • /
    • pp.155-171
    • /
    • 2001
  • The facilities of exhibition and collection for cultural properties is affected by environmental pollution. In order to accumulate a store of basic data, we was investigated eight points(three points at exhibition room and five points at collection room) at four institutes, from December 2000 to March 2001.As a result of investigation, the temperature of A-Exhibition room measured low because of don’t moved HVAC(Heating, Ventilation and Air-Conditioning) System, B Exhibition room is dry for the effect of air-conditioner and the air pollutants concentration of C-Exhibition room is high for the kind of an exhibition room. The air-condition was varied within the open period. The air pollutants concentration of A-Collection room is measured high because the air-pollutants is generated in a new buildings and the air pollutants concentration of C-1 & C-2-Collection room is high for the kind of an collection room. It is necessary to ventilate sufficiently.

  • PDF