Abstract

Thermal analyses have been carried out for a spent fuel dry storage cask under normal and off-normal conditions. Environmental temperature is assumed to be $15^{\circ}C$ under the normal condition. The off-normal condition has an environmental temperature of $38^{\circ}C$. An additional off-normal condition is considered as a partial blockage of the air inlet ducts. Two of the four air inlet ducts are assumed to be completely blocked. The maximum temperatures of the fuel rod and concrete overpack were lower than the allowable values under the normal condition. Temperature distributions for the off-normal conditions were slightly higher than the normal conditions.