• Title/Summary/Keyword: 0.9 V to 5 V

Search Result 2,842, Processing Time 0.04 seconds

Design of low-power OTP memory IP and its measurement (저전력 OTP Memory IP 설계 및 측정)

  • Kim, Jung-Ho;Jang, Ji-Hye;Jin, Liyan;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2541-2547
    • /
    • 2010
  • In this paper, we propose a design technique which replaces logic transistors of 1.2V with medium-voltage transistors of 3.3V having small off-leakage current in repetitive block circuits where speed is not an issue, to implement a low-power eFuse OTP memory IP in the stand-by state. In addition, we use dual-port eFuse cells reducing operational current dissipation by reducing capacitances parasitic to RWL (Read word-line) and BL (Bit-line) in the read mode. Furthermore, we propose an equivalent circuit for simulating program power injected to an eFuse from a program voltage. The layout size of the designed 512-bit eFuse OTP memory IP with a 90nm CMOS image sensor process is $342{\mu}m{\times}236{\mu}m$. It is confirmed by measurement experiments on 42 samples with a program voltage of 5V that we get a good result having 97.6 percent of program yield. Also, the minimal operational supply voltage is measured well to be 0.9V.

Local Anodization on Si surface Using Scanning Probe Microscope; Effects of Tip Voltage, Deflection Setpoint, and Tip Velocity on Line Height (주사탐침현미경을 이용한 Si 표면 국부 산화피막 형성시 선 높이에 대한 탐침 전위, 편향 셋포인트, 탐침 속도의 영향)

  • Kim Chang-Hwan;Choi Jeong-Woo;Shin Woon-Sup
    • Journal of the Korean Electrochemical Society
    • /
    • v.9 no.2
    • /
    • pp.84-88
    • /
    • 2006
  • The effects of tip voltage, deflection setpoint, and tip velocity on height of $SiO_2$ line drawn by local anodization on Si wafer using scanning probe microscope were investigated. No local anodization was detected at smaller than -3 V of tip voltage. The line height increased at rate of 0.47 nm/V when the tip voltage is stronger than -3 V at $1{\mu}m/s$ tip velocity. From deflection setpoint, mechanical force between tip and substrate could be calculated and the threshold farce was $12\sim18nN$. The height of anodized $SiO_2$ lines is independent of the magnitude of force above the threshold force. The line height decreased as increasing the tip velocity and limited to 0.7 nm at -5 V tip voltage.

A Comparative Study on Corrosion Behavior of Ti-35Nb-5Ta-7Zr, Ti-6Al-4V and CP-Ti in 0.9 wt% NaCl

  • Saji, Viswanathan S.;Jeong, Yong Hoon;Choe, Han Cheol
    • Corrosion Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.139-142
    • /
    • 2009
  • Recently, quaternary titanium alloys of the system Ti-Nb-Ta-Zr received considerable research interest as potential implant materials because of their excellent mechanical properties and biocompatibility. However, only few reported works were available on the corrosion behavior of such alloys. Hence, in the present work, electrochemical corrosion of Ti-35Nb-5Ta-7Zr alloy, which has been fabricated by arc melting and heat treatment, was studied in 0.9 wt% NaCl at $37\pm1^{\circ}C$, along with biomedical grade Ti-6Al-4V and CP-Ti. The phase and microstructure of the alloys were investigated employing XRD and SEM. The results of electrochemical studies indicated that the corrosion resistance of the quaternary alloy was inferior to that of Ti-6Al-4V and CP Ti.

Physiological and Ecological Characteristics of Hemolytic Vibrios and Development of Sanitary Countermeasure of Raw Fisheries Foods 3. Growth Factor and Antibiotic Susceptibility of Vibrio cholerae non-O1 FM-3 Isolated from Sea Water (용혈독소를 생산하는 기수성 비브리오균의 생리${\cdot}$생태적 특성과 수산식품의 위생대책 3. 해수에서 분리된 Vibrio cholerae non-O1 FM-3의 생육인자와 항생제 감수성)

  • KIM Shin-Hee;PARK Mi-Yeon;PARK Uk-Yeon;KIM Young-Man;CHANG Dong-Suck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.4
    • /
    • pp.550-555
    • /
    • 1997
  • Vibrio cholerae non-O1 (V. cholerae non-O1) was previously called nonagglutinable or noncholera vibrios, since it fails to react with polyvalent O1 antisera. This organism is biochemically and genetically indistinguishable from V. cholerae O1 except serological difference. V. cholerae non-O1 strains are often detected in the environment including bays, estuaries, and fresh water, and also found in food. Therefore it is designated food borne bacterium in Japan. However, research papers on V. cholerae non-O1 are very rare in Korea. In order to investigate bacteriological characteristics of V. cholerae non-O1, we isolated V. cholerae non-O1 from the environmental sea water. Among the isolated V. cholerae non-O1 strains, we selected the strain which had the most strong hemolytic activity, named as V. cholerae non-O1 FM-3. The optimum growth conditions of V. cholerae non-O1 FM-3 were $37^{\circ}C$ and pH 8.5 in BHI broth (containing $0.5\%$ sodium chloride), and it grew better than V. cholerae non-O1 ATCC 25872. But both were not able to grow in BHI broth added $5.0\%$ of sodium chloride or adjusted to pH 5.0. According to the experimental results on the susceptibility test against various antibiotics, there were no significant differences between the isolated strain and reference strain (V. cholerae non-O1 ATCC 25872). Most of the antibiotics examined had bacteriostatic action against V. cholerae non-O1 FM-3 while vancomycin, oxacillin, colistin, polymyxin B, and sulfadiazine had no bacteriostatic activity.

  • PDF

The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs (분할치료간(Interfraction) 내부 장기 움직임 오류 분석을 통한 전립선암의 전신정위적방사선치료(SBRT) 가능성 평가)

  • Hong, soon gi;Son, sang joon;Moon, joon gi;Kim, bo kyum;Lee, je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.179-186
    • /
    • 2016
  • Purpose : To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. Materials and Methods : This study was based on 5 prostate cancer patients who had IMRT(total dose: 70Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by appling the first treatment plan to each image. Over 5 fractions, the total dose for PTV was $V_{36.25}$ Gy $${\geq_-}$$ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured $V_{100%}$, $V_{95%}$, $V_{90%}$ for CTV and $V_{100%}$, $V_{90%}$, $V_{80%}$ $V_{50%}$ of rectum and bladder. Results : All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, $V_{100%}=0.32%$, $V_{90%}=3.33%$, $V_{80%}=7.71%$, $V_{50%}=23.55%$ in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. Conclusion : There was no case that the value from average of five fractions is over the dosimetric limits. However, dosimetric errors of rectum and bladder in each fraction was significant. Therefore, the precise delivery is needed in case of prostate SBRT. The real-time tracking and adaptive plan is necessary to meet the precision delivery.

  • PDF

Enhanced Ex Vivo Buccal Transport of Propranolol: Evaluation of Phospholipids as Permeation Enhancers

  • Lee, Jae-Hwi;Choi, Young-Wook
    • Archives of Pharmacal Research
    • /
    • v.26 no.5
    • /
    • pp.421-425
    • /
    • 2003
  • The aim of the present study was to evaluate the effects of two phospholipid permeation enhancers, lysophosphatidylcholine (LPC) and didecanoylphosphatidylcholine (DDPC), along with a fusidic acid derivative, sodium taurodihydrofusidate (STDHF) and ethanol (EtOH) on the buccal transport of propranolol hydrochloride (PPL) using an ex vivo buccal diffusion model. The permeation rate of [$^3 H$]PPL as measured by steady-state fluxes increased with increasing EtOH concentration. A significant flux enhancement (P<0.05) was achieved by EtOH at 20 and 30 %v/v concentrations. At a 0.5 %w/v permeation enhancer concentration, the buccal permeation of [$^3 H$]PPL was significantly enhanced by all the enhancers studied (i.e., LPC, DDPC and STDHF) compared to the control (phosphate-buffered saline pH 7.4, PBS). LPC and DDPC displayed a greater degree of permeation enhancement compared with STDHF and EtOH-PBS mixtures with an enhancement ratio of 3.2 and 2.9 for LPC and DDPC, respectively compared with 2.0 and 1.5 for STDHF and EtOH:PBS 30:70 %v/v mixture, respectively. There was no significant difference between LPC and DDPC for the flux values and apparent permeability coefficients of [$^3$H]PPL. These results suggest that phospholipids are suitable as permeation enhancers for the buccal delivery of drugs.

Analysis Study on the Microscopic Characteristics of Freeway Free Flow Speed (고속도로 자유교통류 속도의 미시적 특성에 관한 연구)

  • Yoon, Byoung Jo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2D
    • /
    • pp.105-111
    • /
    • 2010
  • Operating speed is one of key elements in the design and operation of freeway. Few studies have been carried out macroscopically to find characteristics of free-flow speed (FFS) using small sample size and not considering the conditions of traffic volume and the effects of hour periods. As an attempt to find out the characteristics of FFS, this study microscopically analysed both the distributions of freeway FFS and percentile speeds according to traffic volume and daily hour periods using huge sample size. It was found out that speed distributions are changed and showed different behaviors under the conditions of traffic volumes(1-5 veh/30sec) and daily hour periods(0-5, 6-8, 9-11, 12-19, 20-23). V85(85th percentile speed) at morning, night, and midnight period decreases according to increase in traffic volume respectively, whereas V85 at day time does not show considerable differences. So the behaviors of V85 according to hour periods dramatically changed according to the increase in traffic volume.

X-RAY PROPERTIES OF THE PULSAR PSR J0205+6449 IN 3C 58

  • Kim, Minjun;An, Hongjun
    • Journal of The Korean Astronomical Society
    • /
    • v.54 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • We report X-ray timing and spectral properties of the pulsar PSR J0205+6449 measured using NuSTAR and Chandra observatories. We measure the pulsar's rotation frequency ν = 15.20102357(9) s-1 and its derivative $\dot{\nu}=-4.5(1){\times}10^{-11}\;s^{-2}$ during the observation period, and model the 2-30 keV on-pulse spectrum of the pulsar with a power law having a photon index Γpsr = 1.07 ± 0.16 and a 2-30 keV flux F2-30 keV = 7.3±0.6 × 10-13 erg cm-2 s-1. The Chandra 0.5-10 keV data are analyzed for an investigation of the pulsar's thermal emission properties. We use thermal and non-thermal emission models to fit the Chandra spectra and infer the surface temperature T∞ and luminosity Lth of the neutron star to be T∞ = 0.5 - 0.8 MK and Lth = 1 - 5 × 1032 erg s-1. This agrees with previous results which indicated that PSR J0205+6449 has a low surface temperature and luminosity for its age of 800-5600 yrs.

Purification and Characterization of Phenoxazinone Synthase from Streptomyces sp. V-8 Mutant Producing Adenoside Deaminase Inhibitor (아데노신 탈아미노화 효소 억제제를 생산하는 Streptomyces sp. V-8의 변이종으로부터 페녹사지논 합성효소의 분리 및 특성)

  • 김경자;조성진
    • YAKHAK HOEJI
    • /
    • v.43 no.1
    • /
    • pp.68-76
    • /
    • 1999
  • Phenoxazinone synthase catalyzes the oxidative condensation of two molecules of substituted o-aminophenol to the phenoxazinone chromophore of actinomycin. Mutant strain, Streptomyces sp. V-8-M-1 producing higher phenoxazinone synthase, was obtained from Streptomyces sp. V-8 by treatment of N-methyl-N'-nitro-N-nitrosoguanidine. The phenoxazinone synthase was purified from extract of mutant strain of Streptomyces sp. V-8-M-l by successive steps of streptomycin sulfate, ammonium sulfate precipitation. DEAE-cellulose and Sephadex G-200 column chromatography. Molecular weight of the enzyme was 360,000 daltons. The enzyme was composed of octamer of a single subunit of 45,000 daltons. The Km value and Vmax value for 3-HAA were $14.9{\;}{\mu}M$ and 9.5 mg/U, respectively. The optimal pH and temperature for the enzyme activity were 9.0 and $25~30^{\circ}C$, respectively. Treatment of the enzyme with group specific reagents, phenylglyoxal, p-hydroxymercury-benzoate, Nbromosuccinimide, 5.5'-dithiobis-nitrobenzoic acid and ethylmaleimide resulted in loss of enzyme activity, which shows arginine and cysteine residues are at or near the active site.

  • PDF

Insulation Characteristics of Dry-air Insulated Switchgear for 72.5 kV Wind Power Generation (72.5 kV 풍력 발전용 Dry-air Switchgear의 절연 특성)

  • Chan-Hee Yang;Jin-Seok Oh;Hee-Tae Park;Young-il Kim
    • Journal of Wind Energy
    • /
    • v.15 no.2
    • /
    • pp.5-9
    • /
    • 2024
  • This paper describes the insulation breakdown characteristics of 72.5 kV dry-air insulated switchgear under development for installation in a wind power generator when a lightning impulse voltage is applied. For this study, the weak point of insulation due to the electric field concentration of the switchgear's internal shape was identified by finite element method (FEM) analysis, and the shape was actually simulated to measure and analyze the polarity of the lightning impulse voltage and the insulation breakdown characteristics according to the gas pressure at dry-air pressures of 0.1 Mpa to 0.45 Mpa. This study derives the maximum electric field with a 50 % discharge probability for each switchgear internal insulation vulnerable point based on the actual test and electrical simulation, which will be useful as reference data for supplementing and changing insulation design in the future.