• Title/Summary/Keyword: 피폭 선량

Search Result 1,157, Processing Time 0.033 seconds

Cytokinesis-blocked micronuclei in the human peripheral lymphocytes following low dose γ-rays irradiation (저선량의 감마선 피폭된 사람 말초 임파구의 미소핵을 이용한 방사선 생물학적 피폭선량 측정법 연구)

  • Kim, Tae-hwan
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.1
    • /
    • pp.99-104
    • /
    • 2001
  • To determine if micronucleus (MN) assay could be used to predict the absorbed dose of victims after accidental radiation exposure, we carried out to assess the absorbed dose depending on the numerical changes of MN in human peripheral blood lymphocytes after $^{60}Co\;{\gamma}-rays$ exposure in the range of 0.25 to 1 Gy, respectively. The MNs were observed at very low doses, and the numerical changes according to doses. Satisfactory dose-effect calibration curve is observed after low dose irradiation of human lymphocytes in vitro. When plotting on a linear scale against radiation dose, the line of best fit was $Y=(0.02{\pm}0.0009)+(0.033{\pm}0.010)D+(0.012{\pm}0.012)D^2$. The dose-response curve for MN induction immediately after irradiation was linear-quadratic and has a significant relationship between the frequencies of MN and dose. These data show a trend towards increase of the numbers of MN with increasing dose. The number of MN in lymphocytes that were observed in the control group is $0.1610{\pm}0.0093/cell$. Accordingly, MN assay in human peripheral lymphocytes could be a useful in viva model for studying radio-protective drug sensitivity or screening test, microdosimertic indicator and radiation-induced target organ injury. Since MN assay is simple, rapid and reproducible, it will also be a biodosimetric indicator for individual dose assessment after accidental exposure.

  • PDF

Determination of Dose Correction Factor for Energy and Directional Dependence of the MOSFET Dosimeter in an Anthropomorphic Phantom (인형 모의피폭체내 MOSFET 선량계의 에너지 및 방향 의존도를 고려하기 위한 선량보정인자 결정)

  • Cho, Sung-Koo;Choi, Sang-Hyoun;Na, Seong-Ho;Kim, Chan-Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.2
    • /
    • pp.97-104
    • /
    • 2006
  • In recent years, the MOSFET dosimeter has been widely used in various medical applications such as dose verification in radiation therapeutic and diagnostic applications. The MOSFET dosimeter is, however, mainly made of silicon and shows some energy dependence for low energy Photons. Therefore, the MOSFET dosimeter tends to overestimate the dose for low energy scattered photons in a phantom. This study determines the correction factors to compensate these dependences of the MOSFET dosimeter in ATOM phantom. For this, we first constructed a computational model of the ATOM phantom based on the 3D CT image data of the phantom. The voxel phantom was then implemented in a Monte Carlo simulation code and used to calculate the energy spectrum of the photon field at each of the MOSFET dosimeter locations in the phantom. Finally, the correction factors were calculated based on the energy spectrum of the photon field at the dosimeter locations and the pre-determined energy and directional dependence of the MOSFET dosimeter. Our result for $^{60}Co$ and $^{137}Cs$ photon fields shows that the correction factors are distributed within the range of 0.89 and 0.97 considering all the MOSFET dosimeter locations in the phantom.

Radiation Exposure Analysis of Female Nuclear Medicine Radiation Workers (여성 핵의학 방사선종사자의 피폭요인 분석)

  • Lee, Juyoung;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.209-225
    • /
    • 2016
  • In this study, radiation workers who work in nuclear medicine department were analyzed to find the cause of differences of radiation exposure from General Characteristic, Knowledge, Recognition and Conduct, especially females working on nuclear medicine radiation, in order to pave the way for positive defense against radiation exposure. The subjects were 106 radiation workers who were divided into two groups of sixty-four males and forty-two females answered questions about their General Characteristic, Knowledge, Recognition, Conduct, and radiation exposure dose which was measured by TLD (Thermo Luminescence Dosimeter). The results of the analysis revealed that as the higher score of knowledge and conduct was shown, the radiation exposure decreased in female groups, and as the higher score of conduct was shown, the radiation exposure decreased in male groups. In the correlation analysis of female groups, the non-experienced in pregnancy showed decreasing amount of radiation exposure as the score of knowledge and conduct was higher and the experienced in pregnancy showed decreasing amount of radiation exposure as the score of recognition and conduct was higher. In the regression analysis on related factors of radiation exposure dose of nuclear medicine radiation workers, the gender caused the meaningful result and the amount of radiation exposure of female groups compared to male groups. In the regression analysis on related factors of radiation exposure dose of female groups, the factor of conduct showed a meaningful result and the amount of radiation exposure of the experienced in pregnancy was lower compared to the non-experienced. The conclusion of this study revealed that radiation exposure of female groups was lower than that of male groups. Therefore, male groups need to more actively defend themselves against radiation exposure. Among the female groups, the experienced in pregnancy who have an active defense tendency showed a lower radiation exposure. Thus, those who have never been pregnant need to have a more active defensive conduct for the future possibility of pregnancy.

Spatial dose distribution and exposure dose during lumbar lateral test (요추 측면 검사 시 공간선량 분포와 피폭선량)

  • Kim, Chang-Gyu
    • Journal of the Korea Convergence Society
    • /
    • v.5 no.1
    • /
    • pp.17-22
    • /
    • 2014
  • During the lateral x-ray testing of lumbar, in order to obtain the optimal image for diagnosis and to minimize the exposure dose, a glass dosimeter and spatial dose measuring meter was used to measure and evaluate the exposure dose and spatial dose distribution of each organs. The exposure dose of the organs have increased as they were closer to the X-ray tube and when the radiation field was completely opened, the exposure dose was increased. In addition, scattered rays have increased as the distance got closer to the subject and with the distance of more than 200cm, 95% of scattered rays was reduced. Such results can anticipate the exposure dose of patients during the lumbar x-ray test in the future and it can be proposed as a data for determining the testing methods and expected to be widely used as an important basic data for reducing the medical exposure dose.

Study on the Method for Reducing the Operator's Exposure Dose From a C-Arm System (C-Arm 장비의 사용 시 시술자의 피폭선량 저 감화 방법 연구)

  • Kim, Ki-Sik;Song, Jong-Nam;Kim, Seung-Ok
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.493-499
    • /
    • 2016
  • In this study, C-Arm equipment is being used as we intend to verify the exposure dose on the operator by the scattering rays during the operation of the C-Arm equipment and to provide an effective method of reducing the exposure dose. Exposure dose is less than the Over Tube method utilizes the C-arm equipment Under Tube the scheme, The result showed that the exposure dose on the operator decreased with a thicker shield, and as the operator moved away from the center line. Moreover, as the research time prolongated, the exposure dose increased, and among the three affixed location of the dosimeter, the most exposure dose was measured at gonadal, then followed by chest and thyroid. However, in consideration of the relationship between the operator and the patient, the distance cannot be increased infinitely and the research time cannot be decreased infinitely in order to reduce the exposure dose. Therefore, by changing the thickness of the radiation shield, the exposure dose on the operator was able to be reduced. If you are using a C-Arm equipment discomfort during surgery because the grounds that the procedure is neglected and close to the dose of radiation shielding made can only increase. Because a separate control room cannot be used for the C-Arm equipment due to its characteristic, the exposure dose on the operator needs to be reduced by reinforcing the shield through an appropriate thickness of radiation shield devices, such as apron, etc. during a treatment.

TLD's Glow Curve and Radiation Exposure Amount Analysis at Environment with/without Magnetic Field Exposure as Time Passing (시간 경과에 따른 자기장 노출 유·무 환경에서 열형광선량계의 글로우 곡선 및 피폭 방사선량 분석)

  • Lee, Jae-Heon;Ko, Seong-Jin;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.419-426
    • /
    • 2016
  • The research is done to analyze the change of personal dosimeter according to the elapsed times(24 hours, 1 week, 2 weeks, 3 weeks, 4 weeks) and magnetic field and find out the effective exposure treatment for radiation workers. At first, research the heat treatment and radiation of grouped TLD and keep them in different environments-exposed separately to observe the consequences of glow curve and the level of radiation exposure. As a result, we could find that 24 hours passing TLD group showed the difference in glow curve and the level of radiation. This can be considered as the change caused by magnetic exposure. Also the average radiation exposure level of TLD group, unexposed to the magnetic field, was 15.41 mSv. And the average radiation exposure level of TLD group, exposed to the magnetic field, was 14.83 mSv which decreased the biggest amount(3.80%) among the other groups. If a radiation worker, who works in PET-MRI room, uses TLD as a personal dosimeter, the level of real radiation exposure caused by exposure to the magnetic field won't change significantly as recorded at a regular record cycle but with not regular record but interim record, the lower exposure dose will be appeared than the real level of radiation.

The Evaluation of Radiation Dose by Compression paddle meterials in Mammography (유방촬영장치에서 압박대 재료에 따른 피폭선량 평가)

  • Hong, Dong-Hee;Jung, Hong-Ryang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.183-184
    • /
    • 2014
  • 유방촬영은 날로 증가추세에 있으며 압박을 통해 영상을 얻는 것이 화질을 향상시키고 피폭선량을 줄이는데 필수적이다. 그러나 압박대 자체의 두께로 인해 산란선과 피폭선량을 증가시킬 수 있으므로 압박대 재질에 대한 고찰이 필요하다. 현재 임상에서 쓰이고 있는 재질은 폴리카보네이트이며 플라스틱 계열이다. 환자의 피폭선량을 줄이기 위해 노력한다면 이보다 더 좋은 재질에 대해 고려해볼 필요가 있기에 본 연구에서는 플라스틱 계열 물질과 탄소계열의 카본의 방사선투과성에 대해 비교해 보고자 한다.

  • PDF

The Plan of Dose Reduction by Measuring and Evaluating Occupationally Exposed Dose in vivo Tests of Nuclear Medicine (핵의학 체내검사 업무 단계 별 피폭선량 측정 및 분석을 통한 피폭선량 감소 방안)

  • Kil, Sang-Hyeong;Lim, Yeong-Hyeon;Park, Kwang-Youl;Jo, Kyung-Nam;Kim, Jung-Hun;Oh, Ji-Eun;Lee, Sang-Hyup;Lee, Su-Jung;Jun, Ji-Tak;Jung, Eui-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.26-32
    • /
    • 2010
  • Purpose: It is to find the way to minimize occupationally exposed dose for workers in vivo tests in each working stage within the range of the working environment which does not ruin the examination and the performance efficiency. Materials and Methods: The process of the nuclear tests in vivo using a radioactive isotope consists of radioisotope distribution, a radioisotope injection ($^{99m}Tc$, $^{18}F$-FDG), and scanning and guiding patients. Using a measuring instrument of RadEye-G10 gamma survey meter (Thermo SCIENTIFIC), the exposure doses in each working stage are measured and evaluated. Before the radioisotope injection the patients are explained about the examination and educated about matters that require attention. It is to reduce the meeting time with the patients. In addition, workers are also educated about the outside exposure and have to put on the protected devices. When the radioisotope is injected to the patients the exposure doses are measured due to whether they are in the protected devices or not. It is also measured due to whether there are the explanation about the examination and the education about matters that require attention or not. The total exposure dose is visualized into the graph in using Microsoft office excel 2007. The difference of this doses are analyzed by wilcoxon signed ranks test in using SPSS (statistical package for the social science) program 12.0. In this case of p<0.01, this study is reliable in the statistics. Results: It was reliable in the statistics that the exposure dose of injecting $^{99m}Tc$-DPD 20 mCi in wearing the protected devices showed 88% smaller than the dose of injecting it without the protected devices. However, it was not reliable in the statistics that the exposure dose of injecting $^{18}F$-FDG 10 mCi with wearing protected devices had 26% decrease than without them. Training before injecting $^{99m}Tc$-DPD 20 mCi to patient made the exposure dose drop to 63% comparing with training after the injection. The dose of training before injecting $^{18}F$-FDG 10 mCi had 52% less then the training after the injection. Both of them were reliable in the statistics. Conclusion: In the examination of using the radioisotope $^{99m}Tc$, wearing the protected devices are more effective to reduce the exposure dose than without wearing them. In the case of using $^{18}F$-FDG, reducing meeting time with patients is more effective to drop the exposure dose. Therefore if we try to protect workers from radioactivity according to each radioisotope characteristic it could be more effective and active radiation shield from radioactivity.

  • PDF

Development of a Monte Carlo Simulation Code (CALEFF) for Calibrating Thyroid Internal Dose Measurement and Detection Efficiency Calculation (갑상선 내부피폭선량 측정치 보정을 위한 몬테카를로 모의실험 코드 (CALEFF) 개발 및 검출효율 계산)

  • Ahn, Ki-Soo;Cho1, Hyo-Sung
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.117-122
    • /
    • 2005
  • According to the Para. 5 of Art 2 of the Korean Nuclear Safety Regulations, which was revised in 1999, internal dose assessment as well as external one should be performed by law for employees at a nuclear power plant from 2003, and their estimate errors should also be within 50%. Thus, more accurate internal dosimetry becomes important. Corresponding to such regulation revision, we are developing a more accurate thyroid-uptake internal dosimetric system and have developed a Monte Carlo simulation code, the so-called CALEFF, to calculate the detection efficiency of the dosimetric system. In this paper, we calculated detection efficiencies with various test conditions by using the CALEFF code and discussed their characteristics. We may use the detection efficiency calculated by the code in calibrating the thyroid internal dose from measured data.

  • PDF

Analysis of Relationship Between Injection Dose and Exposure Dose in PET/CT Scan: Initial Study (PET/CT에서 방사성 의약품 주입량이 방사선 피폭에 미치는 영향분석: 초기연구)

  • Park, Hoon-Hee;Lyu, Kwang-Yeul
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.351-357
    • /
    • 2011
  • The $^{18}F$-FDG is one of the widely used isotopes for PET/CT scans. Dose amount injected to the patient depends on the characteristics of PET/CT systems. Obviously, the technologists who contact with patients would be exposed as well. In this study, we evaluated the exposed dose of the technologist who works on the PET/CT scanner. The exposed dose were measured every month with the TLDs from 6 technologists. Each technologist is shift-worker who manages 3 different PET/CT systems(Scanner 1(S1): 0.15 mCi/kg, Scanner 2(S2): 0.17 mCi/kg, Scanner 3(S3): 0.12 mCi/kg). The average exposed doses of technologists for each PET/CT system were measured as 0.76 mSv for S1, 0.93 mSv for S2 and 0.47 mSv for S3. The maximum dose was 1.12 mSv and minimum was 0.42 mSv. The results showed that there was a correlation between exposed dose and PET/CT system(p<0.005). Less injected dose for patient occurs less exposed dose for technologist. Various studies for the low dose PET/CT system are required for not only the patient but also the technologist.