• Title/Summary/Keyword: 제작결함

Search Result 610, Processing Time 0.024 seconds

Dielectric passivation effects on the electromigration phenomena in Al-1%Si thin film interconnections (A1-1%Si 박막배선에서 엘렉트로마이그레이션 현상에 미치는 절연보호막 효과)

  • 김경수;김진영
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.27-30
    • /
    • 2001
  • Electromigration Phenomena in Al-1%Si thin film interconnections under DC and PDC conditions were investigated. Thin film interconnections with $SiO_2$ and PSG/$SiO_2$ dielectric passivation layer were formed by a standard photolithography process method and test line lengths were 100, 400, 800, 1200, and 1600 $\mu\textrm{m}$. The current density of $1.19\times10^7\textrm{A/cm}^2$ was stressed in Al-1%Si thin film interconnections under DC condition. The current density of $1.19\times10^7\textrm{A/cm}^2$ was also applied under PDC condition at the frequency of 1 Hz with the duty factor of 0.5. The electromigration resistance of PSG/SiO2 dielectric passivation test line was stronger than $SiO_2$ dielectric passivation test line. The lifetime under PDC was 2-4 times longer than DC condition. As the thin film interconnection line increased, the lifetime decreased and saturated over the critical length. Failure patterns by an electromigration were dominated by void-induced electrical open and hillock-induced electrical short.

  • PDF

Design for Miniaturization of Oscillators using Common DGS (공통 DGS를 이용한 발진기의 소형화 설계)

  • Lim, Jongsik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2443-2448
    • /
    • 2013
  • In this paper, a design of size-reduced microwave oscillator using common defected ground structure (common DGS) is described. At first, an oscillator is designed using the normal stub resonator, and the conventional DGS patterns are inserted for the first trial of size-reduction. Finally, the DGS resonator section is folded by half size in order to adopt the common DGS, and this produces the proposed size-reduced oscillator. Common DGS pattern is inserted for a better size-reduction than when conventional DGSs are used. The folded transmission line is connected using the 3-dimensional signal via-holes. For an example of design, a 2.1GHz oscillator is designed and fabricated using a small signal transistor and common DGS, which shows the size-reduction of 11 mm. The measurement shows 6.7dBm of output power and -133dBc/Hz@1MHz of phase noise. The measured performances are so similar to those of the oscillators before size-reduction and prove the proposed size-reduction method of oscillators using common DGS.

Electrical Degradation Pattern Analysis according to XLPE Cable (XLPE 케이블의 전기적 열화 패턴 분석)

  • Min, Chi-Hyun;Gwak, Dong-Sun;Chun, Hyun-Kwon;Choi, Jin-Wook;Kim, Young-Suk;Kim, Sun-Gu;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.114-120
    • /
    • 2008
  • XLPE cable is using insulator for Cross Linked Polyethylene(XLPE), because insulation Performance is superior and easy comparatively. Need systematization of accident transaction for electrical equipment accident, It is no disposal standard for defect of manufacture and second to accidents. in this paper deals with the change of XLPE cable insulation. To understand the electrical properties of XLPE insulation. Made of XLPE block sample, Penetration fracture Sample and flashover sample. Ogura needles having tip radius of $10[{\mu}m]$ were inserted into each sample. AC voltage of 1[kV/sec] increased at 60[Hz] were apple to breakdown sample and flashover sample. AC voltages of 12[kV], 17[kV] at 60[Hz] were a lied to XLPE block sample. The electrical properties of specimens were measured were measured from initiation of tree and breakdown to their characteristics were analyzed.

An Experimental Study on Failure Behavior of TP316 Stainless Steel Pipe with Local Wall Thinning and Cracking (국부 감육과 균열이 발생한 TP316 스테인리스강 배관의 파괴거동에 관한 실험적 연구)

  • Cheung, Jin Hwan;Kim, In Tae;Choi, Seock Jin;Choi, Hyung Suk;Kim, Hee Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.647-657
    • /
    • 2012
  • Although nuclear power plant piping system is designed conforming to design specifications, the piping systems are deteriorated with increase in service life. In this study, monotonic and cyclic loading tests were carried out on TP316 stainless steel pipe specimens, and the effect of local wall thinning and cracking on failure behavior was investigated. In the tests, 0%, 35% and 75% wall thinning and cracking of initial thickness were artificially introduced to inside elbow and straight pipe specimens, and internal pressures of 20MPa were applied to simulate real operation condition. From the test results, the effect of local wall thinning and cracking on failure mode, ultimate load, number of cycle and strain energy was presented, and maximum bending moment was compared with allowable bending moment calculated by ASME code.

Evaluation on Applicability of Stress Relief Hole for Improvement of Fatigue Stress Capacity of Steel Structural Details (강구조상세부의 피로저항능력 개선을 위한 응력완화홀 적용성 평가)

  • Jung, Kyoung Sup;Nam, Seung Hoon;Kim, Kyoung Nam;Yang, Keon Bong
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.451-461
    • /
    • 2013
  • In steel bridges, there are several details that constrain the deformation such as buckling by external forces. Most of these details which are composed of the intersection members have scallops in order to exclude the weld defects inherently and to get the ease of fabrication and also to decrease the stress concentration. In this study, stress relief hole (SRH) near stress concentration zone with detail category D or under is proposed as a method to improve the resistance on the fatigue crack initiation to detail category C. And the effects of the appropriate size and location of SRH were examined and the applicability to improve the fatigue resistance of the floorbeam web and the rib wall at rib/floorbeam intersection in the orthotropic steel deck bridge was evaluated.

Ultimate Axial Strength of Longitudinally Stiffened Cylindrical Steel Shell for Wind Turbine Tower (풍력발전 타워용 종방향 보강 원형단면 강재 쉘의 극한압축강도)

  • Ahn, Joon Tae;Shin, Dong Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.2
    • /
    • pp.123-134
    • /
    • 2017
  • Ultimate axial strength of longitudinally stiffened cylindrical steel shells for wind turbine tower was investigated by applying the geometrically and materially nonlinear finite element method. The effects of radius to thickness ratio of shell, shape and amplitude of initial imperfections, area ratio between effective shell and stiffener, and stiffener spacing on the ultimate axial strength of cylindrical shells were analyzed. The ultimate axial strengths of stiffened cylindrical shells by FEA were compared with design buckling strengths specified in DNV-RP-C202. The shell buckling modes obtained from a linear elastic bifurcation FE analysis as well as the weld depression during fabrication specified in Eurocode 3 were introduced in the nonlinear FE analysis as initial geometric imperfections. The radius to thickness ratio of cylindrical shell models was selected to be in the range of 50 to 200. The longitudinal stiffeners were designed according to DNV-RP-C202 to prevent the lateral torsional buckling and local buckling of stiffeners.

Development and Animal Tests of Pneumatic Ventricular Assist Device (공압식 심실보조장치의 개발 및 동물실험)

  • 박영환;김상현
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.247-252
    • /
    • 1997
  • Ten acute and chronic in vivo studies were utilized to develop a pneumatic ventricular assist device (VAD) as a bridge to heart transplantation or a circulatory assist device for patients with end-stage heart disease or poor myocardial funct on after cardiac surgery. Two sizes of blood pump of 70cc for adult patients and 34cc for pediatric patients were implanted in the animals. Ventricle of the blood pump was made from the polyurethaae to enhance antithrombogenecity. The VAD was implanted between the left atrium and the descending aorta. Average flow rate was 2.38 L/min for adult and 0.41 L/min for pediatric VAD at the rate of 60 bum. The duration of support ranged from 1 to 26 hours. The most frequent complication was bleeding. Main causes of death were heart failure and respiratory failure. The device function was good for short term use. Studies to date suggest that, with further refinement, a reliable long term VAD that will have clinical application can be developed.

  • PDF

The Study on Magnetioresistance in Fe[NiFe/Cu] Multilayers (Fe[NiFe/Cu] 다층박막의 자기저항 효과에 대한 연구)

  • 박병숙;백주열;이기암;현준원
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.3
    • /
    • pp.258-262
    • /
    • 1996
  • We have investigated the changes in magnetoresistive characteristics, interfacial roughness, and preferred orientation with the Fe buffer layer thickness, annealing temperature, and the stacking number of layers variation in Fe/[NiFe/Cu] multilayers by using the 3-gun d.c. magnetron sputtering method. Intensity of the (200) orientation was increased with the increment of the Fe-buffer layer thickness. We found a maximum magnetoresistance ration of 4.7%, when the buffer layer thickness was 70$\AA$, and the field sensitivity also showed a maximum value at the same thickness. We varied the stacking number of multilayers with fixing the Fe buffer layer thickness of 70$\AA$. When the stacking number was 40 layers, maximum MR ratio(5.3%) was observed. With the variation of annealing temperature no change in the MR ratio was found beyond $300^{\circ}C$. But decrement of MR ratio was observed above $300^{\circ}C$. This decrement of the MR ratio was responsible for the increment of paramagnetic mixed layer caused by the diffusion of Cu layer and the change of antiferromagnetic coupling.

  • PDF

Characterizationof Graphene Modified by Self-Assembled Monolayers on Polyethylene Terephthalate Film

  • Jo, Ju-Mi;Jeong, Dae-Seong;Kim, Yu-Seok;Song, U-Seok;Adhikari, Prashanta Dhoj;Cha, Myeong-Jun;Lee, Su-Il;Jeong, Sang-Hui;Park, Sang-Eun;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.616-616
    • /
    • 2013
  • 그래핀(Graphene)은 열전도도가 높고 전자 이동도(200,000 cm2V-1s-1)가 우수한 전기적 특성을 가지고 있어 전계 효과 트랜지스터(Field effect transistor; FET), 유기 전자 소자(Organic electronic device)와 광전자 소자(Optoelectronic device) 같은 반도체 소자에 응용 가능하다. 최근에는 아크 방출(Arc discharge method), 화학적 기상 증착법(Chemical vapor deposition; CVD), 이온-조사법(Ionirradiation)등을 이용한 이종원자(Hetero atom)도핑과 화학적 처리를 이용한 기능화(Functionalization)등의 방법으로 그래핀의 전도도를 향상시킬 수 있었다. 그러나 이러한 방법들은 기판의 표면을 거칠게 하며, 그래핀에 많은 결함들이 발생한다는 단점이 있다. 이러한 단점을 극복하기 위해 자가조립 단층막법(Self-assembled monolayers; SAMs)을 이용하여 기판을 기능화한 후 그 위에 그래핀을 전사하면, 자가조립 단층막의 기능기에 따라 그래핀의 일함수를 조절 가능하고 운반자 농도나 도핑 유형을 변화시켜 소자의 전기적 특성을 최적화 할 수 있다 [1-3]. 본 연구에서는 PET(polyethylene terephthalate) 기판에 SAMs를 이용하여 유연하고 투명한 그래핀 전극을 제작하였다. 산소 플라즈마와 3-Aminopropyltriethoxysilane (APTES)를 이용하여 PET 기판 표면 위에 하이드록실 기(Hydroxyl group; -OH)와 아민 기(Amine group; -NH2)를 순차적으로 기능화 하였고, 그 위에 화학적 기상 증착법을 이용하여 합성한 대면적의 균일한 그래핀을 전사하였다. PET 기판 위에 NH2 그룹이 존재하는 것을 접촉각 측정(Contact angle measurement)과 X-선 광전자 분광법(Xray photoelectron spectroscopy: XPS)을 통해 확인하였으며, NH2그룹에 의해 그래핀에 도핑 효과가 나타난 것을 라만 분광법(Raman spectroscopy)과 전류-전압 특성곡선(I-V characteristic curve)을 이용하여 확인하였다. 본 연구 결과는 유연하고 투명한 기판 위에 안정적이면서 패턴이 가능하기 때문에 그래핀을 기반으로 하는 반도체 소자에 적용 가능할 것이라 예상된다.

  • PDF

The defects of questions of descriptive assessment in elementary school mathematics and the suggestions for its improvement -focusing on the questions produced by Gyeonggi Provincial Office of Education (초등 수학과 서술형 평가문항의 문제점과 개선방안 -경기도 교육청 창의.서술형 평가 문항을 중심으로-)

  • Chang, Suchin;Kim, Soomi
    • Journal of Elementary Mathematics Education in Korea
    • /
    • v.18 no.2
    • /
    • pp.297-318
    • /
    • 2014
  • This study is designed for helping elementary school teachers have an insight into making or choosing questions of descriptive assessment in mathematics. For this, it is analyzed 30 descriptive mathematical questions produced by Gyeonggi Provincial Office of Education in 2011 and 2012 and 3rd to 6th grade students' papers marked by their teachers in charge from 2 elementary schools located in Gyeonggi Province. The main focus of analysis is the errors of students' answers and teachers' marking not from their own mistakes but from the defects of questions themselves. As a result of analysis, 7 cases of problematic situations are induced and they are reorganized into 3 categories as follow: i) case of not performing unique purpose of descriptive assessment, ii) case of inducing the problem of fairness of grading, iii) case of leading students erroneous direction.

  • PDF