• Title/Summary/Keyword: 방근 성능

Search Result 13, Processing Time 0.032 seconds

A Study on the Root-Resistance Performance of PET film Sheet applied by FRP Coating material (PET 필름 내근시트와 FRP 도막층이 일체화된 방수·방근층의 방근성능에 관한 연구)

  • Kwon, Young-Hwa;Park, Jin-Sang;Kim, Dong-Bum;Park, Wan-Goo;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.253-254
    • /
    • 2018
  • In the construction industry, a variety of Root-Resistance Waterproofing Sheets ar being developed and studied. However, defects still occur in the sheet. In this study, the performance of the navigation is studied by Root-Resistance. As a result of the test, no piercing or penetration marks were found by root in all the specimens.

  • PDF

Performance Evaluation System for Construction Environment of the Unified Waterproofing-Root Resistance Membrane layer of the Green Roof System (인공지반 녹화용 방수방근 복합공법의 시공환경을 고려한 성능평가 시스템 연구)

  • Park, Chang-Hwa;Oh, Sang-Keun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.189-199
    • /
    • 2011
  • Installation of a proper root barrier in a green roof system is very important in order to protect the concrete slab of roof and the root penetration in the waterproofing layer. To select the proper root barrier materials and methods, it is necessary to understand the environmental conditions affecting the waterproofing-root barrier system in green roof construction site. Therefore, we suggested as the environmental performance indexes four kinds of performance requirements; root penetration, chemical attack by chemical agent or fertilizer, load impact by soil depth and size of plant, and water pressure. The related four test methods were suggested for the inspection of these performance indexes. In this research, we could suggest for kinds of test methods as standard test methods to evaluate the environmental performance of waterproofing-root barrier for greening roof system.

Adhesion Performance of Electromagnetic Induction Heating Pixture for the Integration with a Waterproof & Root Barrier Sheet and a Roof Green Unit System (방수·방근시트와 옥상녹화 박스유닛 시스템의 일체화를 위한 전자기 유도가열 융착 고정구의 부착성능)

  • Oh, Chang-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.5
    • /
    • pp.463-469
    • /
    • 2018
  • A currently used roof green system with multi layers has a low constructability. Therefore a new integrated waterproof & root barrier sheet and roof green box unit system was developed using steel plate fixture and cone type fixture by electromagnetic induction heating method. This study was proceeded to evaluate adhesion performance of two types of fixtures on Engineering PE, TPO, PVC sheet in a normal condition, repeated heating and cooling condition. As a result, adhesion load on Engineering PE sheet showed the highest value. The adhesion loads of steel plate fixture showed higher value as heating temperature was getting higher. However adhesion loads of cone type fixture showed opposite tendency. Regarding to the test conditions, test results of normal condition, repeated heating and cooling condition showed same value. The cone type fixture using butyl tape showed 7 times lower adhesion load than that of cone type fixture using electromagnetic heating and 28% lower adhesion load in a repeated heating and cooling condition than a usual condition.

A Study on Test Method for Evaluating Root Resistance in Waterproofing and Root Resistance Membrane Used in Landscape Architecture - A Test Method for Evaluating Root Resistance that Use a Simulated Needle and a Rhizome - (조경 녹화용 방수.방근층의 방근 성능평가 시험방법에 관한 연구 - 모의 바늘과 지하경을 이용한 방근 성능평가 시험방법 -)

  • Yi, Jun-Ho;Pyo, Soon-Ju;Shin, Jin-Hak;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05c
    • /
    • pp.89-97
    • /
    • 2009
  • As landscaping building roofs and concrete structures increase gradually for low carbon green growth policy of government, But waterproofing membranes of those structures are effecting by root penetration of landscape plant. 80, we progressed study about test method for fast evaluating root resistance of waterproofing materials jointly with Tokyo Institute of Technology. The result of the study is as follows: (1) The penetrating load of the needle at the displacement speed of 1mm/min was measured for various membrane to basis and lap joints of membrane, the load force was $3{\sim}50$ N by material variously. (2) According to the test method of deriving rhizomes of bamboo grass to basis and lap joints of membrane, there were no penetrated membrane until present, but need persistent observation. (3) Test method of deriving rhizomes of bamboo grass to basis and lap joints of membrane can shorten from period of 2 years to 1 year for testing. Because rhizomes of bamboo grass can grow from May to September, test is possible in same period.

  • PDF

Assessment of Evaluation by Hybrid Waterproof-Roof Barrier Layer for Green System on Artificial Ground (인공지반 녹화시스템 활용을 위한 일체형 방수·방근 시트의 성능평가)

  • Oh, Chang-Won;Hong, Jong-Chul;Park, Ki-Bong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.4
    • /
    • pp.391-396
    • /
    • 2015
  • The demands about eco friendly space are increased as buildings are denser in downtown, and green system on the roof and the artificial ground are widely being applied. The construction of green system applies a waterproof layer, a root barrier and a protection concrete layer. Assembly of these many layers leads to a long construction term, and cause many defects. This study is to evaluate one layer-hybrid sheet which gets waterproof and root barrier performance simultaneously, which is developed to use in the new green system. As results, the performances of physical properties, durability, waterproof and root barrier not only exceeded quality standards but also showed excellent durability. In addition, mock-up test would be proceed to certify long term performance.

A Standard Test Methods of Resistance to Root Penetration for Waterproofing and Rootproofing Membrane Using Green Roof System (인공지반녹화용 멤브레인 방수 및 방근재료의 방근성능 평가 방법 제안 연구)

  • Lee, Jung-Hoon;Seon, Yun-Suk;Kwak, Kyu Sung;Oh, Sang-Keu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.141-148
    • /
    • 2009
  • The purpose of this paper is to propose a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. Green roof system is considered to be an important subject in construction industry for green growth project. At the same time, we have to consider the counterplan for protection the damage of waterproofing layer and concrete substrate from the penetration of plant root. But many kinds of materials for protection from root penetration are using in construction field. But the performance of those materials is not clear, and there is not test methods for the evaluation of performance. So in this paper, based on the research results of 4 institutes during four years and foreign cases, we made a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. This test method deals with about environmental condition of laboratory, experimental facilities, kinds of plant, specimen of test, management methods, evaluation duration and documents, etc.

  • PDF

Study on tensile performance change by recycled materials of TPO sheet applied to rooftop and artificial ground Rootproofings (옥상 및 인공지반 방근공사에 적용되는 TPO시트의 재생 소재 적용에 따른 인장성능 변화 연구)

  • Kim, Sun-Do;Kim, Jin-Sung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.103-104
    • /
    • 2018
  • Recently, in addition to greening of roof and artificial soil, Rootproofing to prevent damage to the waterproof layer and structures by roots is recognized as an important task. Therefore, various related products and construction methods have been developed and applied in the field. However, in the case of synthetic polymer-based sheets most commonly used in domestic construction sites, Most are produced using 100% new materials that are not suitable for green trends such as resource conservation and environmental protection. Therefore, in this study, we developed TPO sheet using recycled material, which is a technology that can secure eco-friendliness by utilizing recycled resources. As a result of the evaluation of tensile performance of the TPO sheet according to the recycled material content, The tensile strength of the specimens with the recycled content of 50 ~ 70% was the highest, The elongation rate of the specimen with the recycled content of 30 ~ 40% was the best.

  • PDF

Examination Conditions of Root Barrier for Green Roof System and Result of Intermediate Observation of Three Months against Representative Root Barrier (옥상녹화용 방근층의 방근성 시험조건 설정 및 주요 방근소재에 대한 3개월간의 중간관찰 결과)

  • Shin, Yun-Ho;Jang, Dae-Hee;Kim, Hyun-Soo;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.245-249
    • /
    • 2008
  • The purpose of this study is to test performances of 14 types of root barrier materials by applying testing plants and soils suitable for weather and natural features of Korea. For testing plants, Plioblastus pygmaed Mitford A. and Pyracantha angustifolia have been selected. For testing soil, mixture of pearlite and peat moss in 3:1 ratio(volume). Testing container has been fabricated with duplicated structure having inner and outer containers. And the outer container has 2 hinges on its side wall to allow opening and closing. Wet rock wool with 50mm in thickness has been inserted between inner and outer containers to allow root to penetrate through root barrier material and continue to grow. We planted 12 Plioblastus pygmaed Mitford A. and 4 Pyracantha angustifolia per one testing container. Three testing samples have been made for 1 type of root barrier material, which become a total 42 specimens. Planted testing samples have been installed within the greenhouse, which will be observed regularly for 2 years from now on. We started test from July 11, 2008 and had performed intermediate observations every month for initial 3 months. From the 3rd intermediate observation on Sept. 18, we confirmed that 6 types of root barrier materials have penetrated roots. Even though two types of them(EDPM Sheet, Polyethylene Sheet) have been generally used as root barrier materials for roof planting system, all of three testing samples have a lot of penetrated roots. This result proves that it is not reasonable to introduce testing methods of root barrier from Europe or Japan.

  • PDF

A Comparative Study on the Legal System of Building a Rooftop Gardening between Korea and China (한국과 중국의 옥상녹화 제도 비교연구)

  • Zhao, Hong-Xia;Kang, Tai-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.4
    • /
    • pp.11-17
    • /
    • 2011
  • This study focused on the regulations and support system of green rooftop landscaping between Korea and China. Our research found out regulations and support system to review the supplement point to understand the present state of green rooftop landscaping in the two countries. We aimed to provide basic legal information for the development of green rooftop landscaping regulations. Also, a management plan guide and after-evaluation guide were suggested. First, roof load safety is the foremost factor for the structure of green rooftop landscaping. It includes not only considering the weight of construction materials, but also accurately calculating weight of rain, snow and the rooftop's capacity for people when the rooftop is designed. Second, the appropriate waterproof and root material should be selected basing on climatic conditions. Third, a maintenance and management plan needs to be established to regularly check the plant, facilities, soil and to maintain them. Fourth, the criteria of quality inspection are waterproof and root resistant material, and the growth and development of plants. Waterproof and root resistant materials are a very important part of rooftop greening, so they must be strictly inspected after construction. Fifth, the support system of rooftop greening should be continuously improved. The choice of the object and the amount of support should be strictly stipulated so that the construction of rooftop is promoted when volunteers do rooftop greening.

Resistance to Root Penetration of Root Barrier for Green Roof System (옥상녹화용 방근층 구성재료의 방근성능에 관한 실험적 연구)

  • Kim, Hyun-Soo;Jang, Dae-Hee;Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.6
    • /
    • pp.123-129
    • /
    • 2008
  • The purpose of this study is to test performances of 14 types of root barrier materials by applying testing plant: and soils suitable for weather and natural features of Korea. For testing Plants, Plioblastus pygmaed Mitford A and Pyracantha angustifolia have been selected. For testing soil, mixture of pearlite and peat moss in 3:1 ratio Testing container has been fabricated with duplicated structure having inner and outer containers. And the outer container has 2 hinges on its side wall to allow opening and closing. Wet rock wool with 50mm in thickness has been inserted between inner and outer containers to allow root to penetrate through root barrier material and continue to grow. We planted 12 Plioblastus pygmaed Mitford A. and 4 Pyracantha angustifolia per one testing container. Three testing samples have been made for 1 type of root barrier material, which become a total 42 specimens. Planted testing samples have been installed within the greenhouse, which will be observed regularly for 2 years from now on. We started test from July 11, 2008 and had performed intermediate observations every month for initial 3 months. From the 3rd intermediate observation on Sept. 18, we confirmed that 6 types of roe barrier materials have penetrated roots. Even though two types of them have been generally used as root barrier materials for roof planting system, all of three testing samples have a lot of penetrated roots. This result proves that it is not reasonable to introduce testing methods of root barrier from Europe. USA or Japan.