• Title/Summary/Keyword: 김철환

Search Result 830, Processing Time 0.028 seconds

A comparison between digital algorithms for estimation of power system frequency (계통 주파수 추정을 위한 디지털 알고리즘 간의 비교)

  • Lee, B.H.;Kim, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.276-277
    • /
    • 2006
  • Estimation of power system frequency is an important task because frequency deviation is a good indicator of the system abnormal operating conditions. The algorithms, curve fitting, technique using Taylor series, deviation of phasor angle of fundamental waveform using DFT (Discrete Fourier Transform) and Prony method, are tested under operation of the frequency relaying by using EMTP MODELS. The performance of methods is compared with the simulation results.

  • PDF

The development of frequency relaying algorithm considering a transient stability (과도 안정도를 고려한 주파수 계전 알고리즘 개발)

  • Lee, B.H.;Kim, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.282-283
    • /
    • 2006
  • A frequency relaying algorithm which is used system separation and load shedding to improve transient stability is proposed. The algorithm can trip the generator and shed load in the abnormal frequency condition. The computer simulations of load flow analysis is used to determine the amount of load to be shed in an under frequency condition. Furthermore dynamic brake energization in the simulation is performed for the control of overfrequency.

  • PDF

Dynamic Performance Test of Power Transformer Protective Relay using 345kV Transformer Modelling of PSCAD/RTDS (PSCAD/RTDS에서 345kV 변압기 모델링을 통한 변압기용 보호계전기의 동특성 시험)

  • Kwon, Gi-Baek;Kim, Cjul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.120-123
    • /
    • 2005
  • This paper, for the establishment of power system models and test procedures for the dynamic performance test of transformer protective relay, presents power system model, environment establishement between RTDS and protective relay, and the dynamic performance test generated internal fault or external fault.

  • PDF

Neutral Current Calculation in One Step Type Pole (1단장주 중성선 전류 계산)

  • Seo, Hun-Chul;Park, Keon-Woo;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.480-481
    • /
    • 2006
  • This paper presents computation of the neutral torrent using KEPCO's distribution system model which is composed by only one step type poles. The used system model is modelled and simulated by using ATPDraw. And the neutral current is calculated by using EMTP/MODELS.

  • PDF

A Reclosing Technique considering the Distributed Generation (분산전원을 고려한 재폐로 기법)

  • Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.270-271
    • /
    • 2006
  • This paper presents the reclosing algorithm considering the DG(Distributed Generation). The algorithm consists of angle oscillation's judgment, EEEAC(Emergency Extended Equal-Area Criterion), calculation of optimal reclosing time and reconnection algorithm. The simulation is implemented for the three different DG technologies by using EMTP MODELS.

  • PDF

A Calculation of Unbalanced Current on Neutral Line in Two Step Type Pole (2단장주 중성선 불평형 전류 계산)

  • Park, Keon-Woo;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.484-485
    • /
    • 2006
  • The one step type pole and two step type pole are used in KEPCO's distribution system. The neutral current may occurs in three-phase four-wire distribution system due to unbalanced load. This paper presents neutral current both one step type pole and two step type pole in distribution system.