• Title/Summary/Keyword: 기술 정보

Search Result 58,819, Processing Time 0.082 seconds

Design and Implementation of MongoDB-based Unstructured Log Processing System over Cloud Computing Environment (클라우드 환경에서 MongoDB 기반의 비정형 로그 처리 시스템 설계 및 구현)

  • Kim, Myoungjin;Han, Seungho;Cui, Yun;Lee, Hanku
    • Journal of Internet Computing and Services
    • /
    • v.14 no.6
    • /
    • pp.71-84
    • /
    • 2013
  • Log data, which record the multitude of information created when operating computer systems, are utilized in many processes, from carrying out computer system inspection and process optimization to providing customized user optimization. In this paper, we propose a MongoDB-based unstructured log processing system in a cloud environment for processing the massive amount of log data of banks. Most of the log data generated during banking operations come from handling a client's business. Therefore, in order to gather, store, categorize, and analyze the log data generated while processing the client's business, a separate log data processing system needs to be established. However, the realization of flexible storage expansion functions for processing a massive amount of unstructured log data and executing a considerable number of functions to categorize and analyze the stored unstructured log data is difficult in existing computer environments. Thus, in this study, we use cloud computing technology to realize a cloud-based log data processing system for processing unstructured log data that are difficult to process using the existing computing infrastructure's analysis tools and management system. The proposed system uses the IaaS (Infrastructure as a Service) cloud environment to provide a flexible expansion of computing resources and includes the ability to flexibly expand resources such as storage space and memory under conditions such as extended storage or rapid increase in log data. Moreover, to overcome the processing limits of the existing analysis tool when a real-time analysis of the aggregated unstructured log data is required, the proposed system includes a Hadoop-based analysis module for quick and reliable parallel-distributed processing of the massive amount of log data. Furthermore, because the HDFS (Hadoop Distributed File System) stores data by generating copies of the block units of the aggregated log data, the proposed system offers automatic restore functions for the system to continually operate after it recovers from a malfunction. Finally, by establishing a distributed database using the NoSQL-based Mongo DB, the proposed system provides methods of effectively processing unstructured log data. Relational databases such as the MySQL databases have complex schemas that are inappropriate for processing unstructured log data. Further, strict schemas like those of relational databases cannot expand nodes in the case wherein the stored data are distributed to various nodes when the amount of data rapidly increases. NoSQL does not provide the complex computations that relational databases may provide but can easily expand the database through node dispersion when the amount of data increases rapidly; it is a non-relational database with an appropriate structure for processing unstructured data. The data models of the NoSQL are usually classified as Key-Value, column-oriented, and document-oriented types. Of these, the representative document-oriented data model, MongoDB, which has a free schema structure, is used in the proposed system. MongoDB is introduced to the proposed system because it makes it easy to process unstructured log data through a flexible schema structure, facilitates flexible node expansion when the amount of data is rapidly increasing, and provides an Auto-Sharding function that automatically expands storage. The proposed system is composed of a log collector module, a log graph generator module, a MongoDB module, a Hadoop-based analysis module, and a MySQL module. When the log data generated over the entire client business process of each bank are sent to the cloud server, the log collector module collects and classifies data according to the type of log data and distributes it to the MongoDB module and the MySQL module. The log graph generator module generates the results of the log analysis of the MongoDB module, Hadoop-based analysis module, and the MySQL module per analysis time and type of the aggregated log data, and provides them to the user through a web interface. Log data that require a real-time log data analysis are stored in the MySQL module and provided real-time by the log graph generator module. The aggregated log data per unit time are stored in the MongoDB module and plotted in a graph according to the user's various analysis conditions. The aggregated log data in the MongoDB module are parallel-distributed and processed by the Hadoop-based analysis module. A comparative evaluation is carried out against a log data processing system that uses only MySQL for inserting log data and estimating query performance; this evaluation proves the proposed system's superiority. Moreover, an optimal chunk size is confirmed through the log data insert performance evaluation of MongoDB for various chunk sizes.

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

A Study on the Extraction Rate of Brain Tissues from a $^{99m}Tc$-HMPAO Cerebral Blood flow SPECT Examination of a Patient ($^{99m}Tc$-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰)

  • Kim, Hwa-San;Lee, Dong-Ho;Ahn, Byeong-Pil;Kim, Hyun-Ki;Jung, Jin-Yung;Lee, Hyung-Nam;Kim, Jung-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2012
  • Purpose: This study mainly focuses on the patients treated with chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO (d,l-hexamethylpropylene amine oxime) which yielded reduced image quality due to a decreased brain extraction rate. $^{99m}Tc$-HMPAO will be examined further to determine whether this product may be accounted as a factor for this cause. Material and Methods: From January 2010 until December 2010, out of 272 patients who were all subjected to $^{99m}Tc$-HMPAO brain blood flow SPECT scans resulting from Cerebral Infarction; 23 patients(ages $55.3{\pm}9$, 21 males, 3 females) with decreased tissue extraction rate were examined in detail. The radiopharmaceutical product $^{99m}Tc$-HMPAO was used on patients with normal brain tissue exchange rate as well as those with reduced rate in order to prove its' chemical stability. The patients' age, sex, blood pressure, existence of diabetes, drug use, current health status, known side effects from CT/MRI, examination of the patients' past SPECT before/after images were accounted to determine the factors and correlations affecting the rate of blood tissue extractions. Result: After multiple linear regression analysis, there were no unusual correlations between the 6 factors excluding sex, and before/after examination images. Male subjects showed reduced brain tissue extraction rate than the females ($p$ > 0.05) 91.3% male, 8.7% female. Wilcoxon Matched-Pairs Signed-Ranks Test was used on the before/after images which yielded a value of 0.06, which did not indicate a significant amount of difference on the 2 tests ($p$ > 0.05). As a result, the before/after images indicated similar brain tissue extraction rates, and there were variations depending on the individual patient. Conclusion: The effects of the chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO depended on the patient's personal characteristics and status, therefore was considered to be a factor in reducing brain tissue extraction rate. The related articles of $^{99m}Tc$-HMPAO cerebral blood flow SPECT speculates a cerebrovascular disease and factors resulting from portal veins, and it was not possible to pin point the exact cause of decreasing brain tissue extraction rate. However, the $^{99m}Tc$-HMPAO cerebral blood flow SPECT scan proved to be extremely useful in tracking and inspecting brain diseases, as well as offering accurate results from patients suffering from reduced brain tissue extraction rates.

  • PDF

Professional Speciality of Communication Administration and, Occupational Group and Series Classes of Position in National Public Official Law -for Efficiency of Telecommunication Management- (통신행정의 전문성과 공무원법상 직군렬 - 전기통신의 관리들 중심으로-)

  • 조정현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.3 no.1
    • /
    • pp.26-27
    • /
    • 1978
  • It can be expected that intelligence and knowledge will be the core of the post-industrial society in a near future. Accordingly, the age of intelligence shall be accelerated extensively to find ourselves in an age of 'Communication' service enterprise. The communication actions will increase its efficiency and multiply its utility, indebted to its scientic principles and legal idea. The two basic elements of communication action, that is, communication station and communication men are considered to perform their function when they are properly supported and managed by the government administration. Since the communication action itself is composed of various factors, the elements such as communication stations and officials must be cultivated and managed by specialist or experts with continuous and extensive study practices concerned. With the above mind, this study reviewed our public service officials law with a view to improve it by providing some suggestions for communication experts and researchers to find suitable positions in the framework of government administration. In this study, I would like to suggest 'Occupational Group of Communication' that is consisted of a series of comm, management positions and research positions in parallel to the existing series of comm, technical position. The communication specialist or expert is required to be qualified with necessary scientific knowledge and techniques of communication, as well as prerequisites as government service officials. Communication experts must succeed in the first hand to obtain government licence concerned in with the government law and regulation, and international custom before they can be appointed to the official positions. This system of licence-prior-to-appointment is principally applied in the communication management position. And communication research positions are for those who shall engage themselves to the work of study and research in the field of both management and technical nature. It is hopefully expected that efficient and extensive management of communication activities, as well as scientific and continuous study over than communication enterprise will be upgraded at national dimensions.

  • PDF

GET Imaging Evaluation of Patients with Esophageal Cancer (식도암 환자의 GET 영상 평가)

  • Moon, Jong Wun;Lee, Chung Wun;Seo, Young Deok;Yun, Sang Hyeok;Kim, Yong Keun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • Purpose: Measure gastric emptying time (GET: Gastric Emptying Time) is a non-invasive and quantitative evaluation methods, mainly by endoscopic or radiological examination confirmed no mechanical obstruction in patients with symptoms of congestion is checked. Such tests are not common gastric emptying time measured esophageal cancer patients (who underwent esophagectomy) patients after surgery for gastric emptying time was measured test. And the period of time for more than one year after the gastric emptying time measurement was performed. By comparing the two kinds of tests in the chest cavity after surgery as the evaluation of gastrointestinal function tests evaluate the usefulness of GET, and will evaluate the characteristics of the image. Materials and Methods: 93 patients who underwent esophagectomy with gastric emptying time measurement of subject tests immediately after surgery and after 1 year or longer were twice. Preparation of the patient before the test is more than 12 hours of overnight fasting is important, in addition to the medicine or to stop smoking, and diabetes insulin injections should be early in the morning is ideal to test. Generally labeled with $^{99m}Tc-DTPA$ resin which is used to make steamed egg, seaweed and fermented milk with a high viscosity after eating, three hours in the standing position was measured. Evaluation of gastric emptying curves on the way intragastric radioactivity level by 50% the time (half-time [T1/2]) was calculated, based on the half-life was divided into three steps: over 180 minutes was defined as delayed gastric emptying, within 180minutes was defined as intermediate gastric emptying and when all the radioisotopes were dumped into the jejunum as soon as swallowed, was defined as rapid gastric emptying. Results: Gastric emptying time of a typical images stomach of antrum and fundus additional images appear stronger over time move on to the small intestine. but esophageal cancer who underwent esophagectomy side of the thoracic cavity showed a strong image. Immediately after surgery, the half-time (T1/2) of rapid gastric emptying appeared to 12.9%, intermediate gastric emptying appeared to 52.7%, delay gastric emptying appeared to 34.4%. After more than a year the results of the half-life after surgery, 67% of rapid gastric emptying to intermediate gastric emptying was changed, 69% of delay gastric emptying to intermediate gastric emptying changed. Intermediate gastric emptying worse in patients rapid gastric emptying and the delay gastric emptying is 24% in the case. Conclusion: Esophagectomy for esophageal cancer who underwent half-time measurement test (T1/2) rapid gastric emptying and delay gastric emptying are the result of the comparison over time, changes were observed intermediate gastric emptying. Mainly seeing of gastric emptying time measurement in the esophagus instead of thoracic cavity to check the evaluation of gastrointestinal function can be useful even means. And segmentation criteria and narrow time interval of checking if more accurate information and analysis of the clinical diagnosis and evaluation seems to be done.

  • PDF

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

Changes of Housing in the FCS Curricular from the 1st to 2009 Revised of Secondary School (중등학교 가정과 교육과정의 주생활 영역 내용 변화 - 1차 교육과정부터 2009 개정 교육과정을 대상으로 -)

  • Heo, YoungSun;Kim, NamEun;Choi, MinJi;Baek, MinKyung;Gwak, SeonJeong;Cho, JaeSoon
    • Journal of Korean Home Economics Education Association
    • /
    • v.25 no.1
    • /
    • pp.95-118
    • /
    • 2013
  • The purpose of this study was to analyze the contents of housing related to characters, objectives, and contents of FCS curricular from the 1st to 2009 revised curriculum of secondary school. The data were downloaded from the NCIC homepage(http://www.ncic.re.kr/2012. 04. 08) from the 1st(1955. 08) to 2009 revised curriculum(2012. 03) of secondary school. After examining the characters and objectives of each curriculum, contents of housing was analyzed by units and context elements of middle and high school separately. The titles of the subject, the objectives, the instructions, the leaning spheres, weekly hours, grade and gender of candidates, the emphasis of the instruction, etc. have been changed through the curriculum revision. The 6th curriculum was the main period to open to both genders, the $7^{th}$ was the period to combine with technology, the 2007 version was to change the structure of contents of home economics, and the 2009 version switched technology home economics from mandatory to optional in high school. The character of the courses was presented at the 1st curriculum, but it was left out from the $2^{nd}$ to $5^{th}$ curriculum. From the $6^{th}$ curriculum, the characters were separately given to middle and high school. The character of housing area started to appear only in high school home economics from the $7^{th}$ curriculum. The course objectives were described in all curriculum of both middle and high school. This applies to housing area as well. The course objectives have been modified in order to reflect value changes due to social issues. During each curriculum, contents of housing continued to change in context, course load, and candidates. Reflection of housing trends and social needs were the main causes of the change. 2009 version emphasizes on eco-life and sense of community.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

Problems of Environmental Pollution (환경오염의 세계적인 경향)

  • 송인현
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.3.4-5
    • /
    • 1972
  • 생활수준이 낮은 단계에 있어서는 우선 식량에 대한 수요가 강하다. 인간의 욕구가 만족스럽게 먹는다는 것에 대하여 제일 강하게 발동하는 것이다 그러나 점차 과학기술과 산업과 경제가 발전하여 성장과정에 오르게 되고 소득수준도 향상하게 되면 시장기구를 통해서 구입 할 수 있는 개인의 물적 소비재에 대해서는 점차 충족하게 되며 식량이외에도 의복, 전기기구 및 일용생활용품, 자동차 등에 이르기까지 더욱 고차원의 소비재가 보급하게 되는 것이다. 이렇게 되며는 사람의 욕구는 사적 재물이나 물적 수요에서 점진적으로 공공재나 또는 질적 수요(주택, 생활환경 등)의 방향으로 움직이게 되는 것으로써 여기에 환경오염 또는 공해문제에 대하여 의식하게 된다. 그러나 여기에서 더욱이 문제점이 되는 것은 소득 수준의 향상 과정이란 그 자체가 환경오염의 커다란 요인이라는 점이며 자동차의 급격한 보급과 생활의 편의성을 구하여 집중되는 도시인구의 집적, 높은 소득을 보장하기 위한 생산성 높은 중화학공업의 발전 등등은 그 자체가 환경권이란 사람이 요구하는 고차원의 권리를 침해하는 직접적인 요인이 된다는 것이다. 이와 같은 환경오염이나 공해문제에 대한 세계적인 논의는 이미 시작된 지 오래이지만 현재는 우리의 건강보호를 위해서나 생활환경의 보전을 위해서라는 점에서는 그치는 것이 아니고, 더욱 넓혀서 자연의 보호, 자원의 보호라는 견지로 확대되고 있다. 이와 같은 세계적인 확대된 이해와 이에 대한 대책강구의 제안은 1968년 국제연합의 경제사회이사회에서 스웨덴 정부대표에 의하여 제시되었으며 1969년의 우- 탄트 사무총장의 인간환경에 관한 보고서, 1970년 Nixon 미대통령의 연두일반교서 그리고 1972년 5월 6일 스웨덴의 스톡홀롬에서 개최되는 인간환경회의의 주제 등을 통해서 알 수 있고, 종래의 공해나 생활환경의 오염문제라는 좁은 개념에서가 아니고 인간환경전체의 문제로 다루고 있는 것이다. 즉 환경개발(도시, 산업, 지역개발에 수반된 문제), 환경오염(인위적 행위에 의하여 환경의 대인간조건이 악화하는 문제) 자연ㆍ자원의 보호관리(지하, 해양자원, 동식물, 풍경경치의 문제)란 3개 측면에서 다루고 있는 것이다. 환경오염이란 문제를 중 심하여 보면 환경을 구성하는 기본적인 요소로서 대기, 물, 토지 또는 지각. 그리고 공간의 사대요소로 집약하여 생각할 수 있음으로 이 4요소의 오염이 문제가 되는 것이다. 대기의 오염은 환경의 오염중 가장 널리 알려진, 또 가장 오랜 역사를 가진 오염의 문제로써 이에 속하는 오염인자는 분진, 매연, 유해가스(유황산화물, 불화수소, 염화수소, 질소산화물, 일산 화염소 등) 등 대기의 1차 오염과 1차 존재한 물질이 자외선의 작용으로 변화발생 하는 오존, PAN등 광화학물질이 형성되는 2차적인 오염을 들 수 있다. 기외 카도미움, 연등 유해중금속이나 방사선물질이 대기로부터 토지를 오염시켜서 토지에 서식하는 생물의 오염을 야기케 한다는 점등이 명백하여지고 있으며 대기의 오염은 이런 오염물질이 대기중에서 이동하여 강우에 의한 침강물질의 변화를 일으키게 되며 소위 광역오염문제를 발생케하며 동시에 토지의 토질저하등을 가져오게 한다. 물의 오염은 크게 내육수의 오염과 해양의 오염의 양면으로 나누어 볼 수 있다. 하천의 오염을 방지하고 하천을 보호하기 위한 움직임 역시 환경오염의 역사상 오래된 문제이며 시초에는 인분뇨와의 연결에서 오는 세균에 의한 오염이나 양수 기타 일반하수와의 연결에서 오는 오염에 대비하는 것부터 시작하였지만 근래에는 산업공장폐수에 의한 각종 화학적유해물질과 염료 그리고 석유화학의 발달에 의한 폐유등으로 인한 수질오탁문제가 점차 크게 대두되고 있다. 이것은 측 오염이란 시초에 우리에게 주는 불쾌감이 크므로 이것을 피하자는 것부터 시작하여 인간의 건강을 지키고 각종 사용수를 보존하자는 용수보존으로 그리고 이제는 건강과 용수보존뿐만 아니라 이것이 농림 수산물에 대한 큰 피해를 주게됨으로써 오는 자연환경의 생태계보전의 문제로 확대전환하고 있는 것이다. ?간 특히 해양오염에 대한 문제는 국지적인 것에만 끝이는 것이 아니고 전세계의 해양에 곧 연결되는 것이므로 세계각국의 공통관심사로 등장케 되었으며 이것은 특히 폐유가 유류수송 도중에 해양에 투기되는 유류에 의한 해양의 유막성형에서 오는 기상의 변화와 물피해등이 막심함으로 심각화 되고 있다. 각국이 자국의 해안과 해양을 보호하기 위하여 조치를 서두르고 있는 현시점에서 볼 때에는 이는 국제문제화하고 있으며 세계적인 국제적 협력과 협조의 필요성이 강조되는 좋은 예라 하겠다. 토양의 오염에 있어서는 대기나 수질의 오염이 구국적으로 토양과 관련되고 토양으로 환원되는 것이지만 근래에 많이 보급사용되는 농약과 화학비료의 문제는 토양자체의 오염에만 그치는 것이 아니고 농작물을 식품으로 하여 섭취함으로써 발생되는 인체나 기타생물체의 피해를 고려할 때 더욱 중요한 것이며, 또 토질의 저하를 가져오게 하여 농림생산에 미치는 영향이 적지 않을 것이다. 지반강하는 지각 에 주는 인공적 영향의 대표적인 것으로써 지하수나 지하 천연가스를 채취이용하기 위하여 파들어 감으로써 지반이 침하 하는 것이며 건축물에 대한 영향 특히 풍수해시의 재해를 크게 할 우려가 있는 것이다. 공간에 있어서의 환경오염에는 소음, 진동, 광선, 악취 등이 있다. 이들은 특수한 작업환경의 경우를 제외하고는 건강에 직접적인 큰 피해를 준다고 생각할 수 없으나 소음, 진동, 관선, 악취 등은 일반 일상시민생활에 불쾌나 불안을 줌으로써 안정된 생활을 방해하는 요인이 되는 것이다. 공간의 오염물로써 새로운 주목을 끌게된 것은 도시산업폐기물로써 이들은 대기나 물 또는 토지를 오염시킬 뿐만 아니라 공간을 점령함으로써 도시의 미관이나 기능을 손상케 하는 것이다. 즉 노배폐차의 잔해, 냉장고등고형폐기물등의 재생불가능한 것이나 비니루등 합성물질로 된 용기나 포장 등으로 연소분해 되지 않은 내구소비재가 이에 해당하는 것으로 이는 maker의 양식에 호소하여 그 책임 하에 해결되어야 할 문제로 본다. 이렇듯 환경오염은 각양각색으로 그 오염물질의 주요 발생원인 산업장이나 기타 기관에서의 발생요인을 살펴보며는 다음과 같은 것으로 요약할 수 있다. A. 제도적 요인 1. 관리체재의 미비 2. 관리법규의 미비 3. 책임소재의 불명확 B. 자재적 요인 1. 사용자재의 선택부적 2. 개량대책급 연구의 미흡 C. 기술적 요인 1. 시설의 설계불량, 공정의 결함 2. 시설의 점검, 보전의 불충분 3. 도출물의 취급에 대한 검사부족 4. 발생방지 시설의 미설치, 결함 D. 교육적 요인 1. 오염물질 방제지식의 결여 2. 법규의 오해, 미숙지 E. 경제적 요인 1. 자금부족 2. 융자상의 문제 3. 경제성의 문제 F. 정신적 요인 1. 사회적 도의심의 결여(이기주의) 2. 태만 3. 무지, 무관심 등이다. 따라서 환경오염의 방지란 상기한 문제의 해결에 기대하지 않을 수 없으나 이를 해결하기 위하여는 국내적 국제적 상호협조에 의한 사회각층의 총력적 대책이 시급한 것이다. 이와 같은 환경오염이 단속된다 하며는 미구에 인류의 건강은 물론 그 존립마저 기대하기 어려울 것이며, 현재는 점진적으로 급성피해에 대하여는 그 흥미가 집중되어 그 대비책도 많이 논의되고 있지만 미량의 단속접촉에 의한 만성축적에 관한 문제나 이와 같은 환경오염이 앞으로 태어날 신생률에 대한 영향이나 유전정보에 관한 연구는 장차에 대비하는 문제로써 중요한 것이라 생각된다. 기외에 우려되는 점은 오염방지책을 적극 추진함으로써 올 수 있는 파생적인 문제이다. 즉 오염을 방지하기 위하여 생산기업체가 투자를 하게 되며는 그만큼 생산원가가 상승할 것이며 소비가격도 오를 것이다. 반면 이런 시책에 뒤떨어진 후진국의 값싼 생산국은 자연 수입이 억제 당할 것이며, 이렇게되면 후진국은 무역경쟁에서 큰 상처를 입게될 것이고 뿐만 아니라 선진국에 필요한 오염물질의 발생이 높은 생산기기를 자연후진국에 양도하게 될 것임으로 후진국의 환경오염은 배가할 우려가 있는 것이다. 또 해양오염을 방지할 목적에서와 같이 자국의 해안보호를 위하여 마련된 법의 규제는 타국의 선박운항에 많은 제약을 가하게 될 것이며 이것 역시 시설이 미약한 약소후진국의 선박에 크게 영향을 미치게 될 것임으로 교통, 해운, 무역등을 통한 약소후진국의 경제성장에 제동을 거는 것이 될 것이다. 이렇듯 환경오염의 문제는 환경자체에 대해서만 아니라 부산물적으로 특히 후진국에는 의외 문제를 던져주게 되는 것임으로 환경오염에 대해서는 물론, 전술한 바와 같이 인간환경전체의 문제로써 Nixon 대통령이 말한 결의와 창의와 그리고 자금을 가지고 과감하게 대처해 나가야 할 것이다.

  • PDF

Comparison and Evaluation of the Effectiveness between Respiratory Gating Method Applying The Flow Mode and Additional Gated Method in PET/CT Scanning. (PET/CT 검사에서 Flow mode를 적용한 Respiratory Gating Method 촬영과 추가 Gating 촬영의 비교 및 유용성 평가)

  • Jang, Donghoon;Kim, Kyunghun;Lee, Jinhyung;Cho, Hyunduk;Park, Sohyun;Park, Youngjae;Lee, Inwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.54-59
    • /
    • 2017
  • Purpose The present study aimed at assessing the effectiveness of the respiratory gating method used in the flow mode and additional localized respiratory-gated imaging, which differs from the step and go method. Materials and Methods Respiratory gated imaging was performed in the flow mode to twenty patients with lung cancer (10 patients with stable signals and 10 patients with unstable signals), who underwent PET/CT scanning of the torso using Biograph mCT Flow PET/CT at Bundang Seoul University Hospital from June 2016 to September 2016. Additional images of the lungs were obtained by using the respiratory gating method. SUVmax, SUVmean, and Tumor Volume ($cm^3$) of non-gating images, gating images, and additional lung gating images were found with Syngo,bia (Siemens, Germany). A paired t-test was performed with GraphPad Prism6, and changes in the width of the amplitude range were compared between the two types of gating images. Results The following results were obtained from all patients when the respiratory gating method was applied: $SUV_{max}=9.43{\pm}3.93$, $SUV_{mean}=1.77{\pm}0.89$, and $Tumor\;Volume=4.17{\pm}2.41$ for the non-gating images, $SUV_{max}=10.08{\pm}4.07$, $SUV_{mean}=1.75{\pm}0.81$, and $Tumor\;Volume=3.56{\pm}2.11$ for the gating images, and $SUV_{max}=10.86{\pm}4.36$, $SUV_{mean}=1.77{\pm}0.85$, $Tumor\;Volume=3.36{\pm}1.98$ for the additional lung gating images. No statistically significant difference in the values of $SUV_{mean}$ was found between the non-gating and gating images, and between the gating and lung gating images (P>0.05). A significant difference in the values of $SUV_{max}$ and Tumor Volume were found between the aforementioned groups (P<0.05). The width of the amplitude range was smaller for lung gating images than gating images for 12 from 20 patients (3 patients with stable signals, 9 patients with unstable signals). Conclusion In PET/CT scanning using the respiratory gating method in the flow mode, any lesion movements caused by respiration were adjusted; therefore, more accurate measurements of $SUV_{max}$, and Tumor Volume could be obtained from the gating images than the non-gating images in this study. In addition, the width of the amplitude range decreased according to the stability of respiration to a more significant degree in the additional lung gating images than the gating images. We found that gating images provide information that is more useful for diagnosis than the one provided by non-gating images. For patients with irregular signals, it may be helpful to perform localized scanning additionally if time allows.

  • PDF