• 제목/요약/키워드: x-ray film

검색결과 2,293건 처리시간 0.022초

필름 두께 측정용 투과 양극형 x-ray tube의 개발 및 특성 (Development and Characteristics of the x-ray transmission anode tube for the thickness measurement of film)

  • 김성수;김도윤
    • 한국진공학회지
    • /
    • 제17권3호
    • /
    • pp.240-246
    • /
    • 2008
  • 수십에서 수백 ${\mu}m$ 영역의 필름 두께 측정에 적용하기 위한 Ag-target 투과양극형 x-ray tube를 개발하고 특성을 조사하였다. 10kV 부근의 관전압에서 x-ray 에너지의 분포 및 선량특성을 조사하고 W-target tube와 비교하여 논의하였다. 또한 Ag-target tube와 W-target tube를 이용하여 Ny film과 PP film의 두께변화에 따른 x-ray의 투과 특성으로 조사하였고, 그 결과 개발된 x-ray tube는 필름두께 측정용으로 적용할 수 있을 만큼 충분히 좋은 특성을 나타내었다.

EDS 분석과 모델링에 의한 박막두께 측정 방법에 관한 연구 (Determination of Thin Film Thickness by EDS Analysis and its Modeling)

  • 윤재진;이원종
    • 한국전기전자재료학회논문지
    • /
    • 제24권8호
    • /
    • pp.647-653
    • /
    • 2011
  • In this study, a method to measure the thickness of thin film by EDS (energy dispersive spectroscopy) is suggested. We have developed a model which calculates the thickness of thin film from the characteristic x-ray intensity ratio of the elements in thin film and substrate by considering incident electron beam energy, x-ray generation curve, backscattering and absorption of x-ray, take-off angle of x-ray and tilt angle of the sample. We obtained the relation curve between the film thickness measured experimentally and the x-ray intensity ratio of elements. The film thicknesses calculated from the model agrees quite well with those measured experimentally. Therefore, the thin film thickness can be measured rapidly and accurately by using the model developed in this study and the x-ray intensity ratio obtained in EDS analysis.

X선진단(X線診斷) 부문(部門)에 있어서 업무량(業務量)에 관(關)한 조사연구(調査硏究)(II) (A Study on Activities of Diagnostic X-ray Examination(II))

  • 경광현;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제1권1호
    • /
    • pp.44-54
    • /
    • 1978
  • This study was carried out with statistical materials during the last two years of period from Jan. 1975 to Dec. 1976 which presented at radiologic department of 5 hospitals in Seoul City. The primary purpose of this study was to obtained more detailed informations related to the activities of radiologic technologists in diagnostic X-Ray examinations part and to provide some basic materials for managements in activities of then and manpower managements of their organization and practice. From the results of this study, the following conclusions were obtained [1] During two year from the January of 1975 to the December of 1976, total number of case in X-ray examinations were 464,830 case and 22,029 case in 1975 and 24,461 in 1976. And ratio of icreased in X-Ray examinations by year was 11.09 per cent. [2] Regarding the examined portion of X-Ray examination, a great propotion was chest examination as 56.88 per cent. [3] An average, the required time per case in X-Ray exam. was 9.28 minutes and make used of 1.94 sheets of X-Ray film per case in radiography. [4] An average, ratio of increased in X-Ray film by year was 12.71 per cent and ratio of failed film in it was 2.23 per cent. [5] The frequency rate of film size showed the highest distribution of $8"{\times}10"$(28.17%) and the highest distribution of X-Ray film by month was July(8.93%). [6] An average, the amount of activities per a diagnostic X-Ray equipment was 34.92 case and make used of 67.81 sheets of X-Ray film in a day. [7] The mean number of case in X-Ray examinations by radiologic technologists was 29.29 cases and make used of 56.87 sheets of X-Ray film in a day. Also, the average number of case was reading by radiologists was 32.42 case and 62.97 sheets of X-Ray film in a day.

  • PDF

자동현상장치(自動現像裝置)의 현상액(現像液)과 정착액(定着液)의 관리(管理) (Study on the Management of the Developer and Fixing Solution for Automatic X-ray Film Processor)

  • 강홍석;김창균;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제1권1호
    • /
    • pp.61-67
    • /
    • 1978
  • Recently, Demands of automatic X-ray film processors are increasing more and more at general hospitals and private clinics, but various troubles because of incorrect control were found out. Authors have researched to find out the function and activity of automatic X-ray film processor for 70 days with Kodak X-OMAT processor, and results obtained were as follows; 1. Automatic X-ray film processor have an advantage to conduct the rapid treatment of X-ray film processing, but incorrect handling of developing and fixing agents were brought about a great change in contrast and optical density of X-ray film pictures. 2. About 10,000 X-ray films could be finished by same developing and fixing solution without exchanging any other solutions in automatic X-ray film processor.

  • PDF

호흡기 질환에서 단순흉부 X-선 진단 (Plain Chest X-ray Diagnosis of Respiratory Disease)

  • 김상진
    • Tuberculosis and Respiratory Diseases
    • /
    • 제40권4호
    • /
    • pp.353-356
    • /
    • 1993
  • Advent of new imaging modalities such as computed tomography, magnetic resonance imaging and ultrasound contributed greately to the specific imaging diagnosis. However plain chest X-ray is still most prequently used for imaging diagnosis of respiratory disease in clinical pratic and it is important to make a good quality of X-ray film and good interpretation. The optimal chest X-ray should be taken with full inspiration without rotation and motion and the exposure is at the level of barely demonstrable thoracic vertebral disc space. It is recommended that higk KVP technique for detection of lesions which is overlaped by mediastinum, heart and rib cage. It is better to examine chest X-ray film start at some distance(6-8 feet) and closer to the film later on and the reader should not read a film in fatigue condition. The reading room should be quiet and relately dark illumination. It is important, to make a good X-ray film and good interpretation to reduce the observer error.

  • PDF

유방촬영(乳房撮影)의 방사선량(放射線量)에 관(關)한 연구(硏究) (A Study on Radiation Dose in Mammography)

  • 최종학;전만진;김영일;최종운
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제4권1호
    • /
    • pp.31-36
    • /
    • 1981
  • We studied radiation dose in mammography through 34-46 kv range using acryl phantom. The obtained results were as follows: 1. Incident radiation was maximum with high kvp and thin added filtration. 2. Transmitted radiation by acryl phantom and its thickness were in reciprocal relationship. 3. The acryl thickness to produce comparable film density with soft tissue of breast was 6 cm. 4. The X-ray exposure for comparable density radiographs increased mammographic film more than medical x-ray film and the amount of x-ray exposure was directly proportional to the added filtration of x-ray beam. 5. The surface dose of x-ray exposure needed to produce film density of 1.0 for 6cm acryl phantom was 1,084-1,575mR in mammographic film and 476-625 mR in medical x-ray film.

  • PDF

A Polycrystalline CdZnTe Film and Its X-ray Response Characteristics for Digital Radiography

  • Kim, Jae-Hyung;Park, Chang-Hee;Kang, Sang-Sik;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제4권5호
    • /
    • pp.15-18
    • /
    • 2003
  • The Cd$\_$1-x/Zn$\_$x/Te film was produced by thermal evaporation for the flat-panel X-ray detector. The crystal structure and the surface morphology of poly crystalline Cd$\_$1-x/Zn$\_$x/Te film were examined using XRD and SEM, respectively. The leakage current and X-ray sensitivity of the fabricated films were measured to analyze the X-ray response characteristic of Zn in a polycrystalline CdZnTe thin film. The leakage current and the output charge density of Cd$\_$0.7/Zn$\_$0.3/Te thin film were measured to 0.3 1nA/$\textrm{cm}^2$ and 260 pC/$\textrm{cm}^2$ at an applied voltage of 2.5 V/$\mu\textrm{m}$, respectively. Experimental results showed that the increase of Zn doping rates in Cd$\_$1-x/Zn$\_$x/Te detectors reduced the leakage current and improved the X-ray sensitivity significantly. The leakage current was drastically diminished by the formation of thin parylene layer in the Cd$\_$0.7/Zn$\_$0.3/Te detector.

X-ray Response Characteristic of Zn in the Polycrystalline Cd1-xZnxTe Detector for Digital Radiography

  • Kang, Sang-Sik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권2호
    • /
    • pp.28-31
    • /
    • 2002
  • The Cdl-xZnxTe film was fabricated by thermal evaporation for the flat-panel X-ray detector. The stoichimetric ratio and the crystal structure of a polycrystalline Cd$_{1-x}$ Zn$_{x}$Te were investigated by EPMA and XRD, respectively. The leakage current and X-ray sensitivity of the fabricated films were measured to analyze the X-ray response characteristic of Zn in the polycrystalline CdZnTe thin film. The leakage current and the output charge density of Cd$_{0.7}$Zn$_{0.3}$Te thin film were measured to 0.37 nA/cm$^2$ and 260 pc/cm$^2$ at an applied voltage of 2.5 V/${\mu}{\textrm}{m}$, respectively. Experimental results showed that the increase of Zn doping rates in Cd$_{1-x}$ Zn$_{x}$Te detectors reduced the leakage current and improved the signal to noise ratio significantly.

Calibration-free real-time organic film thickness monitoring technique by reflected X-Ray fluorescence and compton scattering measurement

  • Park, Junghwan;Choi, Yong Suk;Kim, Junhyuck;Lee, Jeongmook;Kim, Tae Jun;Youn, Young-Sang;Lim, Sang Ho;Kim, Jong-Yun
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1297-1303
    • /
    • 2021
  • Most thickness measurement techniques using X-ray radiation are unsuitable in field processes involving fast-moving organic films. Herein, we propose a Compton scattering X-ray radiation method, which probes the light elements in organic materials, and a new simple, non-destructive, and non-contact calibration-free real-time film thickness measurement technique by setting up a bench-top X-ray thickness measurement system simulating a field process dealing with thin flexible organic films. The use of X-ray fluorescence and Compton scattering X-ray radiation reflectance signals from films in close contact with a roller produced accurate thickness measurements. In a high-thickness range, the contribution of X-ray fluorescence is negligible, whereas that of Compton scattering is negligible in a low-thickness range. X-ray fluorescence and Compton scattering show good correlations with the organic film thickness (R2 = 0.997 and 0.999 for X-ray fluorescence and Compton scattering, respectively, in the thickness range 0-0.5 mm). Although the sensitivity of X-ray fluorescence is approximately 4.6 times higher than that of Compton scattering, Compton scattering signals are useful for thick films (e.g., thicker than ca. 1-5 mm under our present experiment conditions). Thus, successful calibration-free thickness monitoring is possible for fast-moving films, as demonstrated in our experiments.

구내 표준 방사선사진을 이용한 구내방사선촬영기의 선질 평가 (Evaluation of the Beam Quality of Intraoral X-ray Equipments Using Intraoral Standard Films)

  • 이상섭;권혁락;심우현;오승현;이지연;전국진;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제30권3호
    • /
    • pp.183-188
    • /
    • 2000
  • Purpose: This study was to evaluate the beam quality of intraoral X-ray equipments used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. Materials and Methods : The study was done using the intraoral X -ray equipments used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Results: Most of the HVLs of intraoral X-ray equipments were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANP AS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. Conclusion: HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X -ray equipment should be managed in the planned and organized fashion.

  • PDF